In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission sp...In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission spectrum range:640-740 nm)and coumarin fluorophore(emission spectrum range:440-600 nm)as signal output units,thereby achieving effective spectral separation and highly selective detection of HClO.Under physiological pH conditions,HClO triggers an oxidation-cleavage reaction,releasing methylene blue and coumarin,which emit distinct red and green fluorescence,respectively.This dual-emission feature enabled rapid HClO detection with two-channel detection limits of 25.13 nmol·L^(-1)(green channel)and 31.55 nmol·L^(-1)(red channel).Furthermore,in cell imaging experiments,this probe demonstrated excellent cell membrane permeability and low cytotoxicity,successfully enabling the monitoring of both endogenous and exogenous HClO in living cells.By incorporating a twochannel self-calibration system,the probe effectively mitigated signal variations caused by instrumental or environmental interference,substantially improving detection sensitivity and reliability.展开更多
文摘In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission spectrum range:640-740 nm)and coumarin fluorophore(emission spectrum range:440-600 nm)as signal output units,thereby achieving effective spectral separation and highly selective detection of HClO.Under physiological pH conditions,HClO triggers an oxidation-cleavage reaction,releasing methylene blue and coumarin,which emit distinct red and green fluorescence,respectively.This dual-emission feature enabled rapid HClO detection with two-channel detection limits of 25.13 nmol·L^(-1)(green channel)and 31.55 nmol·L^(-1)(red channel).Furthermore,in cell imaging experiments,this probe demonstrated excellent cell membrane permeability and low cytotoxicity,successfully enabling the monitoring of both endogenous and exogenous HClO in living cells.By incorporating a twochannel self-calibration system,the probe effectively mitigated signal variations caused by instrumental or environmental interference,substantially improving detection sensitivity and reliability.