Aims:To systematically evaluate the clinical efficacy and safety of danhong injection in the treatment of arteriosclerotic occlusion.Methods:Computer retrieval China knowledge network(CNKI),and Wiper Chinese journal d...Aims:To systematically evaluate the clinical efficacy and safety of danhong injection in the treatment of arteriosclerotic occlusion.Methods:Computer retrieval China knowledge network(CNKI),and Wiper Chinese journal database(VIP),and Wanfang data knowledge service platform,the Chinese biomedical literature database(CBM),Pubmed,science citation index(SCI)database,the Cochrane Library,including eight Chinese English database,to conform to the criteria for the two researchers use the recommended bias risk assessment method to evaluate the Cochrane bias risk,extracted data,and apply the Review Manager software Meta analysis and system evaluation.Results:Finally,13 studies were included,with a total number of 884 cases.The results showed that the clinical efficacy of danhong injection in the treatment of arteriosclerotic occlusion was higher than that of conventional treatment,and the difference was statistically significant[OR=3.08,95%CI(2.07,4.60),P<0.00001].The improvement of arteriosclerosis was more obvious[OR=0.15,95%CI(0.12,0.19),P<0.00001].The improvement of hemodynamics was more obvious[OR=-0.19,95%CI(-0.33,-0.04),P=0.01].No adverse reactions occurred.Conclusions:Danhong injection has higher clinical efficacy in the treatment of atherosclerotic occlusion,more obvious improvement in arteriosclerosis degree and hemodynamics,and higher safety.However,due to the low quality of literature research,more high-quality,large samples and randomized controlled double-blind clinical trials are needed to provide high-level evidence to further verify the efficacy and safety of danhong injection in the treatment of atherosclerotic occlusion.展开更多
The frequency stability of a three-dimensional(3D) vacuum encapsulated very high frequency(VHF)disk resonator is systematically investigated. For eliminating the parasitic effect caused by the parasitic capacitanc...The frequency stability of a three-dimensional(3D) vacuum encapsulated very high frequency(VHF)disk resonator is systematically investigated. For eliminating the parasitic effect caused by the parasitic capacitance of the printed circuit board(PCB), a negating capacitive compensation method was developed. The testing results implemented at 25 ℃ for 240 h for the long-term stability indicates that the resonant frequency variation remained within ±1 ppm and the noise floor derived from Allan Deviation was 26 ppb, which is competitive with the conventional quartz resonators. The resonant frequency fluctuation of 1.5 ppm was obtained during 200 temperature cycling between -40 and 85 ℃.展开更多
文摘Aims:To systematically evaluate the clinical efficacy and safety of danhong injection in the treatment of arteriosclerotic occlusion.Methods:Computer retrieval China knowledge network(CNKI),and Wiper Chinese journal database(VIP),and Wanfang data knowledge service platform,the Chinese biomedical literature database(CBM),Pubmed,science citation index(SCI)database,the Cochrane Library,including eight Chinese English database,to conform to the criteria for the two researchers use the recommended bias risk assessment method to evaluate the Cochrane bias risk,extracted data,and apply the Review Manager software Meta analysis and system evaluation.Results:Finally,13 studies were included,with a total number of 884 cases.The results showed that the clinical efficacy of danhong injection in the treatment of arteriosclerotic occlusion was higher than that of conventional treatment,and the difference was statistically significant[OR=3.08,95%CI(2.07,4.60),P<0.00001].The improvement of arteriosclerosis was more obvious[OR=0.15,95%CI(0.12,0.19),P<0.00001].The improvement of hemodynamics was more obvious[OR=-0.19,95%CI(-0.33,-0.04),P=0.01].No adverse reactions occurred.Conclusions:Danhong injection has higher clinical efficacy in the treatment of atherosclerotic occlusion,more obvious improvement in arteriosclerosis degree and hemodynamics,and higher safety.However,due to the low quality of literature research,more high-quality,large samples and randomized controlled double-blind clinical trials are needed to provide high-level evidence to further verify the efficacy and safety of danhong injection in the treatment of atherosclerotic occlusion.
基金Project supported by the National Key Research and Development Program of China(No.2017YFB0405400)the National Natural Science Foundation of China(Nos.61234007,61734007,61404136,61704166)the Key Research Program of Frontier Science of CAS(No.QYZDY-SSW-JSC004)
文摘The frequency stability of a three-dimensional(3D) vacuum encapsulated very high frequency(VHF)disk resonator is systematically investigated. For eliminating the parasitic effect caused by the parasitic capacitance of the printed circuit board(PCB), a negating capacitive compensation method was developed. The testing results implemented at 25 ℃ for 240 h for the long-term stability indicates that the resonant frequency variation remained within ±1 ppm and the noise floor derived from Allan Deviation was 26 ppb, which is competitive with the conventional quartz resonators. The resonant frequency fluctuation of 1.5 ppm was obtained during 200 temperature cycling between -40 and 85 ℃.