Strong surface impact will produce strong vibration,which will pose a threat to the safety of nearby buried pipelines and other important lifeline projects.Based on the verified numerical method,a comprehensive numeri...Strong surface impact will produce strong vibration,which will pose a threat to the safety of nearby buried pipelines and other important lifeline projects.Based on the verified numerical method,a comprehensive numerical parameter analysis is conducted on the key influencing factors of the vibration isolation hole(VIH),which include hole diameter,hole net spacing,hole depth,hole number,hole arrangement,and soil parameters.The results indicate that a smaller ratio of net spacing to hole diameter,the deeper the hole,the multi-row hole,the hole adoption of staggered arrangements,and better site soil conditions can enhance the efficiency of the VIH barrier.The average maximum vibration reduction efficiency within the vibration isolation area can reach 42.2%.The vibration safety of adjacent oil pipelines during a dynamic compaction projection was evaluated according to existing standards,and the measurement of the VIH was recommended to reduce excessive vibration.The single-row vibration isolation scheme and three-row staggered arrangement with the same hole parameters are suggested according to different cases.The research findings can serve as a reference for the vibration safety analysis,assessment,and control of adjacent underground facilities under the influence of strong surface impact loads.展开更多
柔性直流配电系统最常见的故障是单极接地故障。发生单极接地故障后,系统出现故障极与非故障极电压不平衡的现象,对系统安全稳定运行产生威胁,对保护方案的快速性和可靠性提出很高要求。针对此问题,首先分析了柔性直流配电系统线路发生...柔性直流配电系统最常见的故障是单极接地故障。发生单极接地故障后,系统出现故障极与非故障极电压不平衡的现象,对系统安全稳定运行产生威胁,对保护方案的快速性和可靠性提出很高要求。针对此问题,首先分析了柔性直流配电系统线路发生单极接地故障后的故障电流特征,然后验证了故障时线路两端零模电流分量的相关性,最后提出基于线路两端零模电流量相关性的柔性直流配电系统单极接地选线方案。该保护方案充分利用故障后系统固有暂态特征,无需利用边界元件构造边界特性。在实时数字仿真器(Real Time Digital simulator,RTDS)上搭建基于模块化多电平换流器(Modular Multilevel Converter,MMC)的柔性直流配电系统电磁仿真模型验证所述方案的有效性。结果表明该选线方案能够实现快速、可靠识别故障线路,且耐受过渡电阻、噪声、传输延时的能力强,不受交流侧故障影响。展开更多
柔性直流配电线路故障后的过电流极高,需要通过限流的方式降低对高开断电流断路器的需求,而限流后现有的保护原理可能会失效,因此,限流技术与保护原理的结合已成为目前直流配电系统发展的迫切需求。为此,利用控保协同思想,提出了一种全...柔性直流配电线路故障后的过电流极高,需要通过限流的方式降低对高开断电流断路器的需求,而限流后现有的保护原理可能会失效,因此,限流技术与保护原理的结合已成为目前直流配电系统发展的迫切需求。为此,利用控保协同思想,提出了一种全周期限流控制策略与相关性保护原理协同的柔性直流配电线路整体保护方案,能够在限流的同时实现故障识别。所提出的全周期限流控制策略在故障发展的前、中、后期利用不同的限流环节有针对性地抑制故障电流,极大地减轻了直流配电网对于高开断电流断路器的需求;与此同时,利用Pearson相关系数综合描述线路两侧正负极电流极性及波形突变特征,可以同时识别区内外故障并且区分故障类型,减少保护冗余,在限流控制策略作用下仍能够可靠动作。在实时数字仿真器(real time digital simulator,RTDS)中的仿真结果表明:限流控制策略有效降低了故障电流,并且增强了线路两侧电流之间的相关性;保护能够可靠识别故障,不需要严格的通信同步,且不受过渡电阻、数据窗长和噪声的影响,有较好的应用前景。展开更多
道路交通事故多发点事故发生频率高且严重性突出,为提高道路通行的安全与效率,需要找到事故多发点所在位置。针对现有密度聚类算法对交通事故多发点识别时需要设置中心点个数以及容易扩大聚类范围等问题,提出一种限制簇扩展的自适应搜...道路交通事故多发点事故发生频率高且严重性突出,为提高道路通行的安全与效率,需要找到事故多发点所在位置。针对现有密度聚类算法对交通事故多发点识别时需要设置中心点个数以及容易扩大聚类范围等问题,提出一种限制簇扩展的自适应搜索密度峰值聚类算法(limit cluster expansion and adaptive search clustering by fast search and find of density peaks,LA-CFDP)。LA-CFDP算法通过增加中心点限制条件自动确定中心点个数,引入参数扩展因子限制簇扩展范围,从而提高算法对事故多发点识别的适应性和准确性。在英国四个城市2019年交通事故数据集上的实例分析表明,LA-CFDP算法对四个城市聚类结果的轮廓系数值达到0.72~0.92,DBI值均降低到0.37以下。聚类结果符合事故多发点的定义及特征,能够为交通事故多发点治理提供可靠依据。展开更多
柔性直流配电系统发生极间短路故障后,系统短路电流大,对系统安全稳定运行产生威胁,同时考虑到电力电子器件的耐受能力,换流器将会闭锁,导致故障信息量减少,对保护方案的速动性和可靠性提出了很高的要求。针对此问题,文章首先分析了直...柔性直流配电系统发生极间短路故障后,系统短路电流大,对系统安全稳定运行产生威胁,同时考虑到电力电子器件的耐受能力,换流器将会闭锁,导致故障信息量减少,对保护方案的速动性和可靠性提出了很高的要求。针对此问题,文章首先分析了直流线路极间短路故障电流特性,然后揭示了故障时区内外故障电流曲线的积分差异,最后提出基于线路故障电流积分比的极间短路选线方案。在实时数字仿真器(real time digital simulator,RTDS)上搭建基于模块化多电平换流器的直流配电网仿真模型,验证了所述方案的有效性与适用性,具有较好的耐受过渡电阻和抗噪能力。展开更多
基金National Natural Science Foundation of China under Grant Nos.52078386 and 52308496SINOMACH Youth Science and Technology Fund under Grant No.QNJJ-PY-2022-02+2 种基金Young Elite Scientists Sponsorship Program under Grant No.BYESS2023432Fund of State Key Laboratory of Precision Blasting and Hubei Key Laboratory of Blasting Engineering,Jianghan University under Grant No.PBSKL2023A9Fund of China Railway Construction Group Co.,Ltd.under Grant No.LX19-04b。
文摘Strong surface impact will produce strong vibration,which will pose a threat to the safety of nearby buried pipelines and other important lifeline projects.Based on the verified numerical method,a comprehensive numerical parameter analysis is conducted on the key influencing factors of the vibration isolation hole(VIH),which include hole diameter,hole net spacing,hole depth,hole number,hole arrangement,and soil parameters.The results indicate that a smaller ratio of net spacing to hole diameter,the deeper the hole,the multi-row hole,the hole adoption of staggered arrangements,and better site soil conditions can enhance the efficiency of the VIH barrier.The average maximum vibration reduction efficiency within the vibration isolation area can reach 42.2%.The vibration safety of adjacent oil pipelines during a dynamic compaction projection was evaluated according to existing standards,and the measurement of the VIH was recommended to reduce excessive vibration.The single-row vibration isolation scheme and three-row staggered arrangement with the same hole parameters are suggested according to different cases.The research findings can serve as a reference for the vibration safety analysis,assessment,and control of adjacent underground facilities under the influence of strong surface impact loads.
文摘柔性直流配电系统最常见的故障是单极接地故障。发生单极接地故障后,系统出现故障极与非故障极电压不平衡的现象,对系统安全稳定运行产生威胁,对保护方案的快速性和可靠性提出很高要求。针对此问题,首先分析了柔性直流配电系统线路发生单极接地故障后的故障电流特征,然后验证了故障时线路两端零模电流分量的相关性,最后提出基于线路两端零模电流量相关性的柔性直流配电系统单极接地选线方案。该保护方案充分利用故障后系统固有暂态特征,无需利用边界元件构造边界特性。在实时数字仿真器(Real Time Digital simulator,RTDS)上搭建基于模块化多电平换流器(Modular Multilevel Converter,MMC)的柔性直流配电系统电磁仿真模型验证所述方案的有效性。结果表明该选线方案能够实现快速、可靠识别故障线路,且耐受过渡电阻、噪声、传输延时的能力强,不受交流侧故障影响。
文摘柔性直流配电线路故障后的过电流极高,需要通过限流的方式降低对高开断电流断路器的需求,而限流后现有的保护原理可能会失效,因此,限流技术与保护原理的结合已成为目前直流配电系统发展的迫切需求。为此,利用控保协同思想,提出了一种全周期限流控制策略与相关性保护原理协同的柔性直流配电线路整体保护方案,能够在限流的同时实现故障识别。所提出的全周期限流控制策略在故障发展的前、中、后期利用不同的限流环节有针对性地抑制故障电流,极大地减轻了直流配电网对于高开断电流断路器的需求;与此同时,利用Pearson相关系数综合描述线路两侧正负极电流极性及波形突变特征,可以同时识别区内外故障并且区分故障类型,减少保护冗余,在限流控制策略作用下仍能够可靠动作。在实时数字仿真器(real time digital simulator,RTDS)中的仿真结果表明:限流控制策略有效降低了故障电流,并且增强了线路两侧电流之间的相关性;保护能够可靠识别故障,不需要严格的通信同步,且不受过渡电阻、数据窗长和噪声的影响,有较好的应用前景。
文摘道路交通事故多发点事故发生频率高且严重性突出,为提高道路通行的安全与效率,需要找到事故多发点所在位置。针对现有密度聚类算法对交通事故多发点识别时需要设置中心点个数以及容易扩大聚类范围等问题,提出一种限制簇扩展的自适应搜索密度峰值聚类算法(limit cluster expansion and adaptive search clustering by fast search and find of density peaks,LA-CFDP)。LA-CFDP算法通过增加中心点限制条件自动确定中心点个数,引入参数扩展因子限制簇扩展范围,从而提高算法对事故多发点识别的适应性和准确性。在英国四个城市2019年交通事故数据集上的实例分析表明,LA-CFDP算法对四个城市聚类结果的轮廓系数值达到0.72~0.92,DBI值均降低到0.37以下。聚类结果符合事故多发点的定义及特征,能够为交通事故多发点治理提供可靠依据。
文摘柔性直流配电系统发生极间短路故障后,系统短路电流大,对系统安全稳定运行产生威胁,同时考虑到电力电子器件的耐受能力,换流器将会闭锁,导致故障信息量减少,对保护方案的速动性和可靠性提出了很高的要求。针对此问题,文章首先分析了直流线路极间短路故障电流特性,然后揭示了故障时区内外故障电流曲线的积分差异,最后提出基于线路故障电流积分比的极间短路选线方案。在实时数字仿真器(real time digital simulator,RTDS)上搭建基于模块化多电平换流器的直流配电网仿真模型,验证了所述方案的有效性与适用性,具有较好的耐受过渡电阻和抗噪能力。