期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Super Tough, Highly Ionically Conductive, Self-healing Elastomers with Dynamic Metal Coordination Crosslinks for Flexible Sensors
1
作者 Ming-Jun Tang Jian-Hui Yan +3 位作者 Yu-Jun liu Yi Wei yu-xi li Xu-Ming Xie 《Chinese Journal of Polymer Science》 2025年第9期1565-1575,I0009,共12页
Integrated conductive elastomers with excellent mechanical performance,stable high conductivity,self-healing capabilities,and high transparency are critical for advancing wearable devices.Nevertheless,achieving an opt... Integrated conductive elastomers with excellent mechanical performance,stable high conductivity,self-healing capabilities,and high transparency are critical for advancing wearable devices.Nevertheless,achieving an optimal balance among these properties remains a significant challenge.Herein,through in situ free-radical copolymerization of 2-[2-(2-methoxyethoxy)ethoxy]ethyl acrylate(TEEA)and vinylimidazole(VI)in the presence of polyethylene glycol(PEG;Mn=400),tough P(TEEA-co-VI)/PEG elastomers with multiple functionalities were prepared,in which P(TEEA-co-VI)was dynamically cross-linked by imidazole-Zn^(2+)metal coordination crosslinks,and physically blended with PEG as polymer electrolyte to form a homogeneous mixture.Notably,Zn^(2+)has a negligible impact on the polymerization process,allowing for the in situ formation of numerous imidazole-Zn^(2+)metal coordination crosslinks,which can effectively dissipate energy upon stretching to largely reinforce the elastomers.The obtained P(TEEA-co-VI)/PEG elastomers exhibited a high toughness of 10.0 MJ·m^(-3) with a high tensile strength of 3.3 MPa and a large elongation at break of 645%,along with outstanding self-healing capabilities due to the dynamic coordination crosslinks.Moreover,because of the miscibility of PEG with PTEEA copolymer matrix,and Li+can form weak coordination interactions with the ethoxy(EO)units in PEG and PTEEA,acting as a bridge to integrate PEG into the elastomer network.The resulted P(TEEA-co-VI)/PEG elastomers showed high transparency(92%)and stable high conductivity of 1.09×10_(-4) S·cm^(-1).In summary,the obtained elastomers exhibited a well-balanced combination of high toughness,high ionic conductivity,excellent self-healing capabilities,and high transparency,making them promising for applications in flexible strain sensors. 展开更多
关键词 Conductive elastomers TOUGH Metal-coordination SELF-HEALING POLYACRYLATE
原文传递
Influence of electroacupuncture on ghrelin and the phosphoinositide 3-kinase/protein kinase B/endothelial nitric oxide synthase signaling pathway in spontaneously hypertensive rats 被引量:5
2
作者 Yue Zhang Dong-ling Zhong +5 位作者 Ya-ling Zheng yu-xi li Yi-jie Huang Yi-jing Jiang Rong-jiang Jin Juan li 《Journal of Integrative Medicine》 SCIE CAS CSCD 2022年第5期432-441,共10页
Objective To investigate the influence of electroacupuncture(EA)on ghrelin and the phosphoinositide 3-kinase/protein kinase B/endothelial nitric oxide synthase(PI3K/Akt/eNOS)signaling pathway in spontaneously hyperten... Objective To investigate the influence of electroacupuncture(EA)on ghrelin and the phosphoinositide 3-kinase/protein kinase B/endothelial nitric oxide synthase(PI3K/Akt/eNOS)signaling pathway in spontaneously hypertensive rats(SHRs).Methods Eight Wistar-Kyoto rats were used as the healthy blood pressure(BP)control(normal group),and 32 SHRs were randomized into model group,EA group,EA plus ghrelin group(EA+G group),and EA plus PF04628935 group(a potent ghrelin receptor blocker;EA+P group)using a random number table.Rats in the normal group and model group did not receive treatment,but were immobilized for 20 min per day,5 times a week,for 4 continuous weeks.SHRs in the EA group,EA+G group and EA+P group were immobilized and given EA treatment in 20 min sessions,5 times per week,for 4 weeks.Additionally,1 h before EA,SHRs in the EA+G group and EA+P group were intraperitoneally injected with ghrelin or PF04628935,respectively,for 4 weeks.The tail-cuff method was used to measure BP.After the 4-week intervention,the rats were sacrificed by cervical dislocation,and pathological morphology of the abdominal aorta was observed using hematoxylin-eosin(HE)staining.Enzyme-linked immunosorbent assay(ELISA)was used to detect the levels of ghrelin,nitric oxide(NO),endothelin-1(ET-1)and thromboxane A2(TXA2)in the serum.Isolated thoracic aortic ring experiment was performed to evaluate vasorelaxation.Western blot was used to measure the expression of PI3K,Akt,phosphorylated Akt(p-Akt)and eNOS proteins in the abdominal aorta.Further,quantitative real-time polymerase chain reaction(qRT-PCR)was conducted to measure the relative levels of mRNA expression for PI3K,Akt and eNOS in the abdominal aorta.Results EA significantly reduced the systolic BP(SBP)and diastolic BP(DBP)(P<0.05).HE staining showed that EA improved the morphology of the vascular endothelium to some extent.Results of ELISA indicated that higher concentrations of ghrelin and NO,and lower concentrations of ET-1 and TXA2 were present in the EA group(P<0.05).The isolated thoracic aortic ring experiment demonstrated that the vasodilation capacity of the thoracic aorta increased in the EA group.Results of Western blot and qRT-PCR showed that EA increased the abundance of PI3K,p-Akt/Akt and eNOS proteins,as well as expression levels of PI3K,Akt and eNOS mRNAs(P<0.05).In the EA+G group,SBP and DBP decreased(P<0.05),ghrelin concentrations increased(P<0.05),and the concentrations of ET-1 and TXA2 decreased(P<0.05),relative to the EA group.In addition,the levels of PI3K and eNOS proteins,the p-Akt/Akt ratio,and the expression of PI3K,Akt and eNOS mRNAs increased significantly in the EA+G group(P<0.05),while PF04628935 reversed these effects.Conclusion EA effectively reduced BP and protected the vascular endothelium,and these effects may be linked to promoting the release of ghrelin and activation of the PI3K/Akt/eNOS signaling pathway. 展开更多
关键词 ELECTROACUPUNCTURE Hypertension Vascular endothelial dysfunction GHRELIN PI3K/Akt/eNOS signaling pathway
原文传递
Super Tough Hydrogels with Self-adaptive Network Facilitated by Liquid Metal
3
作者 Rong-Ze Gao yu-xi li +2 位作者 Jian-Hui Yan Xue-Rui Ma Xu-Ming Xie 《Chinese Journal of Polymer Science》 SCIE EI CAS CSCD 2023年第6期866-873,I0006,共9页
Liquid metals(LM)refer to Ga-based alloys with low melting points such as Eutectic GaInSn alloys(EGaInSn),which have excellent fluidity,flexibility and low toxicity at room temperature.In this work,by incorporating EG... Liquid metals(LM)refer to Ga-based alloys with low melting points such as Eutectic GaInSn alloys(EGaInSn),which have excellent fluidity,flexibility and low toxicity at room temperature.In this work,by incorporating EGaInSn into poly(acrylic acid)(PAA)hydrogels as dynamic crosslinkers and effective energy-dissipating units,tough and strong PAA-LM hydrogels are prepared through the interactions between the oxide layers on the surface of LM and carboxyl groups of PAA chains.Moreover,owing to the fluidity of LM,one LM droplet as a cross-linking point may change its shape or break into more and smaller droplets in the hydrogels upon stretching.Then hydrogels with self-adaptive networks can be fabricated by mechanical training through cyclic stretch at a certain elongation.Thus,the networks of the hydrogels are further homogenized,and the hydrogels are significantly toughened during the training due to the increased cross-linking density from the larger number of smaller LM droplets.After a 5-cycle training at the maximum strain of 500%and 24 h recovering,the tensile strength and initial modulus of the PAA-LM hydrogels can be increased from 355 kPa to 597 kPa and 71 kPa to 166 kPa,respectively,while the elongation at break only decreases from 1491%to 1034%. 展开更多
关键词 temperature. LINKING STRETCHING
原文传递
Thirty-day outcomes of in-hospital multi-vessel versus culpritonly revascularization strategy for ST-segment elevation myocardial infarction with multivessel coronary disease 被引量:5
4
作者 yu-xi li Bei-Ning WANG +6 位作者 Fang-Fang FAN Yan ZHANG Jie JIANG Jian-Ping li Ya-ling HAN Yong Huo CCC investigators 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第7期485-494,共10页
BACKGROUND Many studies have demonstrated the benefit of complete multivessel revascularization versus culprit-only intervention in patients of ST-segment elevation myocardial infarction(STEMI)and multivessel coronary... BACKGROUND Many studies have demonstrated the benefit of complete multivessel revascularization versus culprit-only intervention in patients of ST-segment elevation myocardial infarction(STEMI)and multivessel coronary artery disease.However,only a few single-center retrospective studies were performed on small Chinese cohorts.Our study aims to demonstrate the advantage of multivessel percutaneous intervention(PCI)strategy on 30-day in-hospital outcomes to patients with STEMI and multivessel disease in larger Chinese population.METHODS From the Improving Care for Cardiovascular Disease in China-Acute Coronary Syndrome(CCC-ACS)project,5935 patients with STEMI and multivessel disease undergoing PCI and hospitalized for fewer than 30 days were analyzed.After 5:1 propensity score matching,3577 patients with culprit-only PCI and 877 with in-hospital multivessel PCI were included.The primary outcome was major adverse cardiovascular and cerebrovascular event(MACCE),defined as a composite of myocardial infarction,all-cause death,stent thrombosis,heart failure,and stroke.RESULTS Multivariable logistic regression analysis revealed that in-hospital multivessel PCI was associated with lower risk of 30-day MACCE(adjusted OR=0.75,95%CI:0.57-0.98,P=0.032)than culprit-only PCI and conferred no increased risk of allcause death,myocardial infarction,stent thrombosis,stroke,or bleeding.Subgroup analysis showed that MACCE reduction was observed more often from patients with trans-femoral access(OR=0.34,95%CI:0.15-0.74)than with trans-radial access(OR=0.87,95%CI:0.66-1.16,P for interaction=0.017).CONCLUSIONS The in-hospital multivessel PCI strategy was associated with a lower risk of 30-day MACCE than culprit-only PCI in patients with STEMI and multivessel coronary artery disease. 展开更多
关键词 INFARCTION CORONARY MYOCARDIAL
暂未订购
Lunar Penetrating Radar onboard the Chang'e-3 mission 被引量:19
5
作者 Guang-You Fang Bin Zhou +11 位作者 Yi-Cai Ji Qun-Ying Zhang Shao-Xiang Shen yu-xi li Hong-Fei Guan Chuan-Jun Tang Yun-Ze Gao Wei Lu Sheng-Bo Ye Hai-Dong Han Jin Zheng Shu-Zhi Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2014年第12期1607-1622,共16页
Lunar Penetrating Radar (LPR) is one of the important scientific instru- ments onboard the Chang'e-3 spacecraft. Its scientific goals are the mapping of lunar regolith and detection of subsurface geologic structure... Lunar Penetrating Radar (LPR) is one of the important scientific instru- ments onboard the Chang'e-3 spacecraft. Its scientific goals are the mapping of lunar regolith and detection of subsurface geologic structures. This paper describes the goals of the mission, as well as the basic principles, design, composition and achievements of the LPR. Finally, experiments on a glacier and the lunar surface are analyzed. 展开更多
关键词 Chang'e-3 mission -- moon rover -- Lunar Penetrating Radar
在线阅读 下载PDF
Corrosion behavior of thermal-sprayed WC cermet coatings in SO_4^(2-) environment 被引量:2
6
作者 Yan liu Xiao-Min Wang +5 位作者 Sheng-bo Cen Guo-Qing Gou li-Jun Wang Hui Chen Ming-Jing Tu yu-xi li 《Rare Metals》 SCIE EI CAS CSCD 2014年第3期318-323,共6页
A series of the electrochemical and long-term corrosion tests was carried out in a 3.5 wt% Na2SO4 solution on thermal-sprayed WC-17Co and WC-10Co-4Cr cermet coatings in order to examine the effect of composition of bi... A series of the electrochemical and long-term corrosion tests was carried out in a 3.5 wt% Na2SO4 solution on thermal-sprayed WC-17Co and WC-10Co-4Cr cermet coatings in order to examine the effect of composition of binder materials on the corrosion behavior. The results reveal that the overall corrosion resistance of the WC-17Co coating is inferior to that of the WC-Co-Cr coatings due to the corrosion of binder materials which induce WC particles to fall off. CoO and WO3 oxide films form on the surface of WC-17Co coating in Na2SO4 solution electrochemical corrosion process, which will protect the coating in the process of corrosion. Cr2O3 oxide film formed on the WC-10Co-4Cr coating surface has a strong hindered role to corrosion. The corrosion mechanism of WC-17Co coating in Na2SO4 solution is entire corrosion of Co matrix, while it is film-hole corrosion mechanism for WC-10Co-4Cr coating. 展开更多
关键词 WC-CO WC-Co-Cr Corrosion ELECTROCHEMICAL
原文传递
Ultra-thin ALD CoO_(x)-ZnO heterogenous films as highly sensitive and environmentally friendly H_(2)S sensor 被引量:1
7
作者 Qing-Min Hu Zhe Dong +7 位作者 Gai-Xia Zhang yu-xi li Shuang-Feng Xing Zhi-Heng Ma Bo-Yu Dong Bo Lu Shu-Hui Sun Jia-Qiang Xu 《Rare Metals》 SCIE EI CAS CSCD 2023年第9期3054-3063,共10页
To obtain environmentally friendly,integrated and miniaturized gas sensors for the increasing request for the Internet of Things industry and other relative areas,the ultra-thin CoO_(x)/Zn O heterogeneous film with ac... To obtain environmentally friendly,integrated and miniaturized gas sensors for the increasing request for the Internet of Things industry and other relative areas,the ultra-thin CoO_(x)/Zn O heterogeneous film with active interfacial sites was in-situ deposited on micro-electro-mechanical systems(MEMS)as H_(2)S sensor.Atomic layer deposition(ALD)was employed to in-situ fabricate the uniform Zn O thin film.ALD CoO_(x)was deposited on ZnO surface to obtain CoO_(x)/Zn O heterojunction and active interfacial sites.The ultra-thin film(20 nm)with 50 ALD Co O_(x)decorated on 250 ALD Zn O displays excellent sensing performance,including very high response(4.45@200×10^(-9))and selectivity to H_(2)S with a limit of detection(LOD)of 0.38×10^(-9),long-term sensing stability,high response/recovery performance(7.5 s/15.7 s)and mechanical strength at 230。C.Reasons for the high sensing performance of CoO_(x)/Zn O have been confirmed by series of characterizations and density functional theory(DFT)calculation.Heterojunction film thickness with Debye length,the oxygen vacancies and the synergistic effect of active interfacial sites are main reasons for the high sensing performance.The strategy by fabrication of CoO_(x)/Zn O heterogeneous film within Debye length and employing synergistic effect of active interfacial sites offers a promising route for the design of environmentally friendly gas sensors.Furthermore,the ALD technique offers a facile in-situ strategy and high-throughput fabrication of MEMS gas sensors. 展开更多
关键词 Atomic layer deposition(ALD) Surface decoration CoO_(x)/ZnO active interfacial sites H_(2)S gas sensor
原文传递
Pulmonary hypertension concurrent with pericardial effusion and superior vena cava syndrome: who is the initiator? 被引量:1
8
作者 Bei-Ning WANG yu-xi li +4 位作者 Wei MA Song-Yun CHU Zhi-Hao liU Wen-Hui DING Jian-Ping li 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第11期723-727,I0002,共6页
The diagnosis of pulmonary hypertension(PH) should be made by combining clinical manifestations and echocardiographic probability.[1] Following the confirmation of PH, the classification should begin with the more com... The diagnosis of pulmonary hypertension(PH) should be made by combining clinical manifestations and echocardiographic probability.[1] Following the confirmation of PH, the classification should begin with the more common groups [group 2(PH due to left heart disease) and group 3(PH due to lung diseases and/or hypoxia)], then group 4(chronic thromboembolic PH and other pulmonary artery obstructions) and finally group 1(pulmonary arterial hypertension) and group 5(PH with unclear and/or multifactorial mechanisms).[1] In this case, we demonstrate a rare scenario of obstruction-caused group 4 PH. 展开更多
关键词 MALIGNANCY Pericardial effusion Pulmonary hypertension Superior vena cava syndrome
暂未订购
Reciprocating Magnetic Fields in the Pulsar Wind Observed from the Black Widow Pulsar J1720-0534 被引量:1
9
作者 Chen-Chen Miao Victoria Blackmon +41 位作者 Wei-Wei Zhu Dong-Zi li Ming-Yu Ge Xiao-Peng You Maura McLaughlin Di li Na Wang Pei Wang Jia-Rui Niu M.Cruces Jian-Ping Yuan Jun-Tao Bai D.J.Champion Yu-Tong Chen Ming-Min Chi P.C.C.Freire Yi Feng Zhen-Ye Gan M.Kramer Fei-Fei Kou yu-xi li Xue-li Miao ling-Qi Meng Chen-Hui Niu Sheng-Nan Sun Zhong-Yi Sun H.M.Tedila Shuang-Qiang Wang Qing-Dong Wu Jing-Bo Wang Zhi-Gang Wen Shen Wang Ya-Biao Wang Cheng-Jie Wang Meng-Yao Xue You-ling Yue Mao Yuan Ju-Mei Yao Wen-Ming Yan Ru-Shuang Zhao Lei Zhang De Zhao 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2023年第10期255-266,共12页
We report the radio observations of the eclipsing black widow pulsar J1720-0534, a 3.26 ms pulsar in orbit with a low mass companion of mass 0.029 to 0.034 M⊙. We obtain the phase-connected timing ephemeris and polar... We report the radio observations of the eclipsing black widow pulsar J1720-0534, a 3.26 ms pulsar in orbit with a low mass companion of mass 0.029 to 0.034 M⊙. We obtain the phase-connected timing ephemeris and polarization profile of this millisecond pulsar(MSP) using the Five-hundred-meter Aperture Spherical radio Telescope(FAST), the Green Bank Telescope(GBT), and the Parkes Telescope. For the first time from such a system, an oscillatory polarization angle change was observed from a particular eclipse egress with partial depolarization, indicating 10-milliGauss-level reciprocating magnetic fields oscillating in a length scale of 5 ×10^(3)km(assuming an orbital inclination angle of 90°) outside the companion's magnetosphere. The dispersion measure variation observed during the ingresses and egresses shows the rapid raising of the electron density in the shock boundary between the companion's magnetosphere and the surrounding pulsar wind. We suggest that the observed oscillatory magnetic fields originate from the pulsar wind outside the companion's magnetosphere. 展开更多
关键词 (stars:)pulsars:general (stars:)pulsars:individual(J1720-0534) (stars:)binaries:eclipsing
在线阅读 下载PDF
Pseudo-Wellens syndrome secondary to postexercise syncope
10
作者 Shu Fang Zhi-hao liu +5 位作者 Qi Jin yu-xi li Wen-hui Ding Hao-yu Weng Tie-ci Yi Jian-ping li 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第4期334-336,共3页
Dear editor,Wellens syndrome is characterized by electrocardiography(ECG)patterns of the biphasic or inverted T wave in the precordial leads with normal R wave progression and absence of Q waves,[1,2]which indicates o... Dear editor,Wellens syndrome is characterized by electrocardiography(ECG)patterns of the biphasic or inverted T wave in the precordial leads with normal R wave progression and absence of Q waves,[1,2]which indicates occlusive lesions of the proximal left anterior descending(LAD)coronary artery and warrants.[1]These ECG changes usually occur during a pain-free interval and turn to a fatal consequence if without urgent intervention therapy.[1,3]However,in some cases,coronary stenosis was absent and ECG patterns manifested as Wellens syndrome,which was defined as pseudo-Wellens syndrome. 展开更多
关键词 CORONARY EDITOR CONSEQUENCE
暂未订购
Sex modification of the association of the radial augmentation index and incident hypertension in a Chinese community-based population
11
作者 Qiao QIN Fang-Fang FAN +11 位作者 Meng-Yuan liU Bo liU Jia JIA Long ZHANG yu-xi li Yi-Meng JIANG Peng-Fei SUN Dan-Mei HE Jian-Ping li Ming CHEN Bo ZHENG Yan ZHANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2021年第1期39-46,共8页
BACKGROUND Arterial stiffness,as assessed by aortic ultrasound and pulse wave velocity,is associated with incident hypertension.However,there is still no consensus on whether the augmentation index(AI)affects new onse... BACKGROUND Arterial stiffness,as assessed by aortic ultrasound and pulse wave velocity,is associated with incident hypertension.However,there is still no consensus on whether the augmentation index(AI)affects new onset of hypertension.This study investigated the relationship of radial AI(r AI)and incident hypertension in a Chinese community-based population without hypertension at baseline.METHOD A total of 1,615 Chinese non-hypertensive participants from an atherosclerosis cohort in Beijing,China were included in our analysis.Baseline r AI normalized to heart rate of 75 beats/min(r AIp75)was obtained using HEM-9000 AI.New-onset hypertension was defined as blood pressure≥140/90 mm Hg or self-reported hypertension or taking anti-hypertensive medications at the follow up survey.Multivariate regression models were used to evaluate the impact of r AIp75 on the risk of new-onset hypertension.RESULTS After a mean 2.35-year follow-up,213(13.19%)participants developed incident hypertension.No significant relation between r AIp75 and incident hypertension was observed in the whole population after adjustment for possible confounders(adjusted odds ratio(OR)and 95%confidence interval(CI):1.09[0.95-1.27];P=0.2260).However,r AIp75 was significantly associated with incident hypertension in women,but not in men(adjusted OR and 95%CI:1.29[1.06-1.56],P=0.0113 for women;0.91[0.72-1.15],P=0.4244 for men;P for interaction=0.0133).CONCLUSIONS Sex modified the effect of the r AI on incident hypertension in a Chinese,community-based,non-hypertensive population.Screening of the r AI could be considered in women with a high risk of hypertension for the purpose of primary intervention. 展开更多
关键词 Sex modification of the association of the radial augmentation index and incident hypertension in a Chinese community-based population
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部