期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Improvement of a temperature response function for divertor heat flux monitoring in fusion devices
1
作者 Xuan Nhat Son BUI Hiroto MATSUURA yousuke nakashima 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第3期217-221,共5页
Temperature response functions have been developed to investigate sensor design and divertor heat flux estimation in magnetically confined plasmas. The time-dependent heat flux can be derived by fitting the response f... Temperature response functions have been developed to investigate sensor design and divertor heat flux estimation in magnetically confined plasmas. The time-dependent heat flux can be derived by fitting the response function to experimental thermocouple(TC) data. Because the TC signals have a time delay to transit events such as discharge start or confinement transition, the time delay is taken into account in a temperature response function. Such a function accurately describes the signal from each TC channel with time delay in a sensor test using a neutral beam injection. Measurement for commercial TCs shows that the time delay is caused by the finite heat capacity of TC wire and contact heat resistance between TC and target surface. 展开更多
关键词 DIVERTOR temperature response function thermocouple system primary delay