Kalman filter based fault diagnosis of networked control system with white noise 被引量:5
1
作者 YanweiWANG yingzheng 《控制理论与应用(英文版)》 EI 2005年第1期55-59,共5页
The networked control system NCS is regarded as a sampled control system withoutput time-variant delay. White noise is considered in the model construction of NCS. By using theKalman filter theory to compute the filte... The networked control system NCS is regarded as a sampled control system withoutput time-variant delay. White noise is considered in the model construction of NCS. By using theKalman filter theory to compute the filter parameters, a Kalman filter is constructed for this NCS.By comparing the output of the filter and the practical system, a residual is generated to diagnoseme sensor faults and the actuator faults. Finally, an example is given to show the feasibility ofthe approach. 展开更多
关键词 networked control system fault diagnosis kalman filter
在线阅读 下载PDF
钢管-RPC轴拉承载力试验研究 被引量:1
2
作者 姚鹏宇 黄文金 +1 位作者 应铮 李靖 《河北工程大学学报(自然科学版)》 CAS 2018年第2期25-30,共6页
为了确定钢管-钢纤维活性粉末混凝土(RPC)轴拉性能,通过共40根钢管-RPC试件的轴拉试验,对比分析了不同养护温度、钢纤维体积掺量和钢管壁厚的钢管-RPC轴拉试件的应变增长模式和破坏机理。研究结果表明,钢管-RPC轴拉荷载-应变增长模式与... 为了确定钢管-钢纤维活性粉末混凝土(RPC)轴拉性能,通过共40根钢管-RPC试件的轴拉试验,对比分析了不同养护温度、钢纤维体积掺量和钢管壁厚的钢管-RPC轴拉试件的应变增长模式和破坏机理。研究结果表明,钢管-RPC轴拉荷载-应变增长模式与钢管混凝土类似;钢管-RPC初裂荷载约为峰值荷载的25%;钢管-RPC的轴拉极限承载力可参考钢管混凝土抗拉承载力的定义方法进行确定。 展开更多
关键词 钢纤维活性粉末混凝土 组合结构 开裂承载力 极限承载力 直接轴拉试验