期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
POLYMER NETWORK-POLY(ETHYLENE GLYCOL)COMPLEXES WITH SHAPE MEMORY EFFECT
1
作者 yi-ping Cao +1 位作者 C.W.Yip 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2003年第1期29-33,共5页
The complexes of poly(methacrylic acid-co-methyl methacrylate) network with poly(ethylene glycol) stabilized byhydrogen bonds were prepared. By introducing the poly(ethylene glycol), a large difference in storage modu... The complexes of poly(methacrylic acid-co-methyl methacrylate) network with poly(ethylene glycol) stabilized byhydrogen bonds were prepared. By introducing the poly(ethylene glycol), a large difference in storage modulus below andabove the glass transition temperature occurred and the complexes exhibited shape memory behaviors. The morphology ofcomplexes was studied by using DSC, WAXD, and DMA. The results indicate that the fixed phase of this kind of novelshape memory materials is the network, and the reversible phase is the amorphous state of PEG:PMAA complex phase. Theshape recoverability almost reaches 100%. This type of complexes can be regarded as a novel shape memory network. 展开更多
关键词 Hydrogen bonded complex Shape memory effect Storage modulus ratio
在线阅读 下载PDF
Effect of Electroacupuncture on Heart Meridian for Change of End-Diastolic Intraventricular Pressure with Myocardial Ischemia in Rabbits
2
作者 FANG Zhi-bin +6 位作者 (方志斌) WANG Yue-lan (王月兰) ZHOU yi-ping (周逸平) 《Chinese Journal of Integrative Medicine》 SCIE CAS 2002年第1期59-61,共3页
Objective: To explore the relationship between Heart Meridian (HM) and cardiac function. Methods: Thirty rabbits with acute myocardial ischemia resulting from intravenous dripping of pituitrin was established. Electr... Objective: To explore the relationship between Heart Meridian (HM) and cardiac function. Methods: Thirty rabbits with acute myocardial ischemia resulting from intravenous dripping of pituitrin was established. Electroacupuncture (EA) on the HM and the Lung Meridian (LM) was applied, 3 points for each, and their change of end diastolic intraventricular pressure observed. Results: Obvious difference existed in the improvement of end diastolic intraventricular pressure on the HM and LM with EA treatment. The regulatory action of EA in HM on the cardiac function was significantly better than that of EA in LM. Conclusion: HM was closely related to the cardiac function. 展开更多
关键词 Heart Meridian myocardial ischemia end diastolic intraventricular pressure ELECTROACUPUNCTURE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部