A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted wi...A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to form soluble Prussian blue,which is monitored at 735 nm.The calibration graphs are linear in the concentration ranges of(1―100)×10-6 mol/L for cysteine and N-acetyl cysteine,and(1―50)×10-6 mol/L for glutathione.The relative standard deviations of 1.8%,2.5% and 1.9% were found for eleven replicate analyses of 5×10-6 mol/L cysteine,N-acetyl cysteine and glutathione.The limits of detection(3σ blank) at 5×10-7 mol/L for cysteine,and 3×10-7 mol/L for N-acetyl cysteine and glutathione were obtained.The proposed method allowed 60 injections/h.The effects of common substances present in pharmaceuticals and human physiological fluids were examined.The method was applied to determining cysteine in pharmaceutical formulations with the recoveries in a range of 97% to 106% and the results obtained are agreed well with labeled values.展开更多
A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ...A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly.展开更多
文摘A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to form soluble Prussian blue,which is monitored at 735 nm.The calibration graphs are linear in the concentration ranges of(1―100)×10-6 mol/L for cysteine and N-acetyl cysteine,and(1―50)×10-6 mol/L for glutathione.The relative standard deviations of 1.8%,2.5% and 1.9% were found for eleven replicate analyses of 5×10-6 mol/L cysteine,N-acetyl cysteine and glutathione.The limits of detection(3σ blank) at 5×10-7 mol/L for cysteine,and 3×10-7 mol/L for N-acetyl cysteine and glutathione were obtained.The proposed method allowed 60 injections/h.The effects of common substances present in pharmaceuticals and human physiological fluids were examined.The method was applied to determining cysteine in pharmaceutical formulations with the recoveries in a range of 97% to 106% and the results obtained are agreed well with labeled values.
基金Supported by the CIIT-Project Funded by COMSATS Institute of Information Technology,Pakistan
文摘A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly.