期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Effect of coating material and lubricant on forming force and surface defects in wire drawing process 被引量:5
1
作者 S.M.BYON S.J.LEE +2 位作者 D.W.LEE y.h.lee Y.LEE 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第A01期104-110,共7页
A pilot wire drawing machine as well as wire end-pointing roller was developed. Using these machines, a wire drawing test for four different coating materials and two different lubricants was performed as the reductio... A pilot wire drawing machine as well as wire end-pointing roller was developed. Using these machines, a wire drawing test for four different coating materials and two different lubricants was performed as the reduction ratio increased from 10% to 30%. Materials used for a substrate in this study are plain carbon steel (AIS11045) and ultra low carbon bainite steel. To compute the friction coefficient between the coating layer of wire and the surface of die lbr a specific lubricant, a series of finite element analyses were carried out. SEM observations were also conducted to investigate the surface defects of wire deformed. Results show that the behavior of drawing force varies with the lubricant-type at the initial stage of drawing. The powder-typed lubricant with a large particle causes the retardation of lull lubrication on the entire contact surface and the local delamination of coating layer on the wire surface. As the flow stress of a substrate increases, the delamination becomes severe. 展开更多
关键词 COATING LUBRICANT wire drawing DELAMINATION
在线阅读 下载PDF
肝外胆管癌的肝胆管-胰腺分期 被引量:4
2
作者 Y.E.chung M.J.Kim +3 位作者 Y.N.Park y.h.lee J.Y.Choi 李志伟 《国际医学放射学杂志》 2008年第A06期522-522,共1页
肝外胆管癌的术前分期对选择最佳的治疗计划至关重要。有些分类系统被建议用于确定手术可行性和范围。不同术式的选择依赖于肿瘤的范围。
关键词 胆管癌 肝外胆管癌 分期
暂未订购
RELIABILITY OF A AIR-PUFF NONCON-TACT TONOMETER EVUALTED UNDER OPTIMAL STANDARDIZED TESTING EN-VIRONMENT
3
作者 M.Y.W.Kuo y.h.lee 《国际眼科杂志》 CAS 2003年第1期54-54,共1页
Introduccion: Pneumotonometers are handy equipments for testing intraocular pressures (IOP) both for physicians and patients and doesn&#8217;t transmit infectious illnesses, but are also known to have a less stabl... Introduccion: Pneumotonometers are handy equipments for testing intraocular pressures (IOP) both for physicians and patients and doesn&#8217;t transmit infectious illnesses, but are also known to have a less stable estimation of the IOP values comparing to the conventional Goldmann applanation tonometer. Objective: In this study, we try to define the range of 展开更多
关键词 非接触式 气鼓式眼压计 最优标准化测试环境 可靠性 评价
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部