A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fr...A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fraction)phosphoric acid water(pH=2.2)as the mobile phase.Three active substances in cosmetics were quantitatively detected simultaneously at a detection wavelength of 265 nm.The linear ranges of β-nicotinamide mononucleotides,ergothioneine and nicotinamide are 10~200 mg/L,5~100 mg/L and 5~100 mg/L respectively and the detection limits of three components are 3.0 mg/L,1.5 mg/L and 1.5 mg/L respectively.The recovery rate is 97.1~104.9%,with RSD≤2.0%.The method was applied to quantitative analysis of five samples of cosmetics toner,lotion,cream,essence and gel and three samples of raw materials.The results showed that the results of β-nicotinamide mononucleotide and ergothioneine in five cosmetics were consistent with the product label,while nicotinamide was inconsistent with the label.The purity of the three raw material samples was 99.5%,99.7% and 100.8%respectively.This method offers high precision,accuracy and short analysis time,making it a reliable approach for studying three active ingredients in cosmetics and suitable for quality control of related functional ingredients.展开更多
文摘A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fraction)phosphoric acid water(pH=2.2)as the mobile phase.Three active substances in cosmetics were quantitatively detected simultaneously at a detection wavelength of 265 nm.The linear ranges of β-nicotinamide mononucleotides,ergothioneine and nicotinamide are 10~200 mg/L,5~100 mg/L and 5~100 mg/L respectively and the detection limits of three components are 3.0 mg/L,1.5 mg/L and 1.5 mg/L respectively.The recovery rate is 97.1~104.9%,with RSD≤2.0%.The method was applied to quantitative analysis of five samples of cosmetics toner,lotion,cream,essence and gel and three samples of raw materials.The results showed that the results of β-nicotinamide mononucleotide and ergothioneine in five cosmetics were consistent with the product label,while nicotinamide was inconsistent with the label.The purity of the three raw material samples was 99.5%,99.7% and 100.8%respectively.This method offers high precision,accuracy and short analysis time,making it a reliable approach for studying three active ingredients in cosmetics and suitable for quality control of related functional ingredients.