期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate
1
作者 Samy Emara Tsutomu Masujima +2 位作者 walaa zarad Maha Kamal Ramzia EL-Bagary 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第1期28-35,共8页
A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determ... A new simple, sensitive and precise green analytical procedure using an automated packed-reactor derivatization technique coupled with on-line solid-phase enrichment (SPEn) has been developed and evaluated to determine trace levels of methotrexate (MTX). The method was based on injection of MTX into a flowing stream of phosphate buffer (0.04 M, ptt 3.4), carried through the packed oxidant reactor of Cerium (IV) trihydroxyhydroperoxide for oxidative cleavage of the drug into highly fluorescent product, 2,4-diaminopteridine- 6-carboxylic acid, followed by SPEn on a head of short ODS column (10mm x 4.6 mm i.d., 5 I+tm particle size). The flow rate was 0.25 mL/min and packed reactor temperaturc was 40 ~C. The trapped product was back-flush eluted from the ODS column to the detector by column-switching with an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 5:95 (v/v). The eluent was monitored at emission and excitation wavelengths of 460 and was linear over the concentration range of 1.25-50 360 nm, respectively. The calibration curve ng/mL with a detection limit of 0.08 ug/ml..The method was successfully applied to determine MTX in pharmaceutical formulations with mean percentage recovery ranging from 99.48 to 99.60. 展开更多
关键词 METHOTREXATE Flow injection analysis Cerium (IV) trihydroxy-hydroperoxide On-line solid-phaseenrichment Fluorescence detection
暂未订购
Coupling of on-Line Pre-Column Oxidative Cleavage and Solid-Phase Enrichment with Liquid Chromatography Using an Eco-Friendly Analytical Procedure to Determine Low Levels of Methotrexate
2
作者 Samy Emara walaa zarad +1 位作者 Maha Kamal Ramzia EL-Bagary 《Journal of Analytical Sciences, Methods and Instrumentation》 2012年第4期194-202,共9页
A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 m... A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX. 展开更多
关键词 Cerium (IV) Trihydroxyhydroperoxide HPLC METHOTREXATE ODS ANALYTICAL Column ON-LINE Pre-Column Oxidative CLEAVAGE
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部