A 78-year-old woman with a background of type 2 diabetes mellitus,hyperlipidaemia and hypertension experienced sudden onset severe chest pain while in the emergency department,after a stressful emotional event.The pai...A 78-year-old woman with a background of type 2 diabetes mellitus,hyperlipidaemia and hypertension experienced sudden onset severe chest pain while in the emergency department,after a stressful emotional event.The pain lasted for 20-30 min and the patient developed widespread T-wave inversion on 12-lead ECG.展开更多
Stripper gas and terminal potential play a key role for the charge state distribution in a tandem pelletron accelerator. The knowledge of this distribution is important for experiments performed on tandem accelerators...Stripper gas and terminal potential play a key role for the charge state distribution in a tandem pelletron accelerator. The knowledge of this distribution is important for experiments performed on tandem accelerators. The charge state distribution of B, C, Si, Ni, Cu and Au beams is measured by using Ar as stripper gas, and terminal potential is varied from 0.3 to 3.0 MV on 5UDH-2 tandem pelletron accelerator installed at the National Centre for Physics, Islamabad. The individual charge state is measured after the switching magnet at 15° in high-energy portion. It is observed that the higher charge states are stable in the range of lower and middle atomic masses of periodic table, whereas higher atomic mass(Au) shows beam current instability in higher charge states. For carbon,the charge distribution at 1.7 MV terminal potential by varying stripper gas pressure is also studied, which resulted in decreased overall transmission with good current value for higher charge states.展开更多
文摘A 78-year-old woman with a background of type 2 diabetes mellitus,hyperlipidaemia and hypertension experienced sudden onset severe chest pain while in the emergency department,after a stressful emotional event.The pain lasted for 20-30 min and the patient developed widespread T-wave inversion on 12-lead ECG.
文摘Stripper gas and terminal potential play a key role for the charge state distribution in a tandem pelletron accelerator. The knowledge of this distribution is important for experiments performed on tandem accelerators. The charge state distribution of B, C, Si, Ni, Cu and Au beams is measured by using Ar as stripper gas, and terminal potential is varied from 0.3 to 3.0 MV on 5UDH-2 tandem pelletron accelerator installed at the National Centre for Physics, Islamabad. The individual charge state is measured after the switching magnet at 15° in high-energy portion. It is observed that the higher charge states are stable in the range of lower and middle atomic masses of periodic table, whereas higher atomic mass(Au) shows beam current instability in higher charge states. For carbon,the charge distribution at 1.7 MV terminal potential by varying stripper gas pressure is also studied, which resulted in decreased overall transmission with good current value for higher charge states.