期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
带交叉肋方形截面通道内强制对流换热的实验研究 被引量:7
1
作者 邓斌 t.t.wong 陶文铨 《西安交通大学学报》 EI CAS CSCD 北大核心 2002年第9期881-885,共5页
在雷诺数为 5 0 0 0~ 4 0 0 0 0的范围内 ,对以不同角度 (45°、6 0°、75°)布置的、具有不同高度 (4mm、5mm)的交叉肋条的方形截面通道内的强制对流换热进行了实验研究 .实验结果表明 :对交叉布置的肋条 ,其角度越大 ,... 在雷诺数为 5 0 0 0~ 4 0 0 0 0的范围内 ,对以不同角度 (45°、6 0°、75°)布置的、具有不同高度 (4mm、5mm)的交叉肋条的方形截面通道内的强制对流换热进行了实验研究 .实验结果表明 :对交叉布置的肋条 ,其角度越大 ,高度越高 ,对流换热增强得越明显 ,但同时阻力也大为增加 ;与平行布置的肋条相比 ,交叉布置的肋条虽能使对流换热有所增强 ,但阻力增加的程度大于换热的增加 .就换热与阻力的总体效果来说 ,在雷诺数较低时 ,交叉肋条有一定的优越性 ,但在高雷诺数下 。 展开更多
关键词 方形截面通道 强制对流换热 实验研究 交叉肋 传热强化 交叉布置 平行布置
在线阅读 下载PDF
A Novel Parsimonious Neurofuzzy Model Applied to Railway Carriage System Identification and Fault Diagnosis 被引量:1
2
作者 S.C.Zhou O.L.Shuai +1 位作者 t.t.wong T.P.Leung 《International Journal of Plant Engineering and Management》 1997年第4期7-11,共5页
In this paper, we suggest a novel parsimonious neurofuzzy model realized by RBFNs for railway carriage system identification and fault diagnosis. To overcome the curse of dimensionality resulting from high dimensional... In this paper, we suggest a novel parsimonious neurofuzzy model realized by RBFNs for railway carriage system identification and fault diagnosis. To overcome the curse of dimensionality resulting from high dimensional input variables, in our developed model the features extracted from the available observations are regarded as the input variables by adopting the higher-order statistics(HOS) technique. Such a constructed model is also applied to a practical railway carriage system, simulation results indicate that the developed neurofuzzy model possesses strong identification and fault diagnosis ability. 展开更多
关键词 parsimonious neurofuzzy model feature extraction by Higher-Order Statistics (HOS) railway carriage system identification and fault diagnosis
在线阅读 下载PDF
Forced Convective Heat Transfer and Pressure Drop of Air Flowing in a Rectangle Duct with Cross-Ribs on the Opposite Walls 被引量:1
3
作者 B.Deng t.t.wong W.Q.Tao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2002年第3期259-270,共12页
Experiments were conducted to investigate the forced convective heat transfer and flow friction of turbulent airflow in a rectangular duct with cross-ribs attached at the two principal walls in the Reynolds number ran... Experiments were conducted to investigate the forced convective heat transfer and flow friction of turbulent airflow in a rectangular duct with cross-ribs attached at the two principal walls in the Reynolds number range from 5000 to 40000. The effect of the rib cross angle (45° 60° 75° and the height (4 mm, 5 mm) of the cross-ribs on the forced convection and flow friction were tested. Non-dimensional correlations for the duct average Nusselt number and friction factor of cross-ribs duct were developed from the test data. Experiments were also conducted for the corresponding parallel ribs to compare their relative performance. The experimental results show that both of the convective heat transfer coefficient and friction factor were increased with cross-ribs, with 45°cross-ribs being the best. Compared with parallel ribs normal to the flow direction under identical flow rate and identical pumping power constraints, the cross-ribs can enhance heat transfer in the lower Reynolds number region, while 展开更多
关键词 cross-ribs FORCED convection heat transfer enhancement.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部