期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Performance and Flow Condition of Small-Sized Axial Fan and Adoption of Contra-Rotating Rotors 被引量:9
1
作者 t.shigemitsu J.Fukutomi Y.Okabe 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第1期1-6,共6页
Small-sized axial fans are used as air coolers for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotatio... Small-sized axial fans are used as air coolers for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotational speed design is conducted,although it causes the deterioration of the efficiency and the increase of noise.Then the adoption of contra-rotating rotors for the small-sized axial fan is proposed for the improvement of the performance.In the present paper,the performance and the internal flow condition of the small-sized axial fan are shown as a first step of the research for the contra-rotating small-sized axial fan and the important points to apply contra-rotating rotors to the small-sized axial fan are discussed.Furthermore,the numerical flow analysis is conducted to investigate the performance of the contra-rotating small-sized axial fan and internal flow conditions and pressure distributions are clarified and the effect of contra-rotating rotors is considered. 展开更多
关键词 Small-sized axial fan Contra-rotating rotors Numerical analysis PERFORMANCE Internal flow
原文传递
The Effect of Blade Outlet Angle on Performance and Internal Flow Condition of Mini Turbo-Pump 被引量:8
2
作者 t.shigemitsu J.Fukutomi +1 位作者 R.Nasada K.Kaji 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第1期32-38,共7页
Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields;automobile radiator pump,ventricular assist pump,cooling pump for electric devices,washing machine pump and so on.Further,the needs for... Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields;automobile radiator pump,ventricular assist pump,cooling pump for electric devices,washing machine pump and so on.Further,the needs for mini turbo-pumps would become larger with the increase of the application of it for electrical machines.It is desirable that the mini turbo-pump design is as simple as possible due to restriction to make precise manufactures.But the design method for the mini turbo-pump is not established because the internal flow condition for these small-sized fluid machineries is not clarified and conventional theory is not conductive for small-sized pumps.Three types of rotors with different outlet angles are prepared for an experiment and a numerical analysis.The performance tests are conducted with these rotors in order to investigate the effect of the blade outlet angle on performance and internal flow condition of mini turbo-pumps.It is clarified from the experimental results that head of the mini turbo-pump increases and maximum efficiency flow rate shifts to larger flow rate according to the increase of the blade outlet angle,however the maximum efficiency decreases with the increase of it.In the present paper,the performance of the mini turbo-pump is shown and the internal flow conditions are clarified with the results of the experiment and the numerical flow analysis.Furthermore,the effects of the blade outlet angle on the performance are investigated and high performance design with simple structure for the mini turbo-pump would be considered. 展开更多
关键词 Mini Turbo-Pump Centrifugal pump PERFORMANCE Internal flow Blade outlet angle
原文传递
Performance and Internal Flow of Sirocco Fan Using Contra-Rotating Rotors 被引量:2
3
作者 J.Fukutomi t.shigemitsu T.Yasunobu 《Journal of Thermal Science》 SCIE EI CAS CSCD 2008年第1期35-41,共7页
A sirocco fan using contra-rotating rotors in which an inner rotor is settled inside the sirocco fan rotor and each rotor rotates in an opposite direction was proposed for the purpose of getting the higher pressure an... A sirocco fan using contra-rotating rotors in which an inner rotor is settled inside the sirocco fan rotor and each rotor rotates in an opposite direction was proposed for the purpose of getting the higher pressure and making the structure of a sirocco fan more compact. If the high discharge pressure is obtained with the adoption of the contra-rotating rotors, it could be used for various purposes. Pressure coefficient of a sirocco fan with contra-rotating rotors is 2.5 times as high as the conventional sirocco fan and the maximum efficiency point of contra-rotating rotors shifts to larger flow rate than a conventional sirocco fan. On the other hand, it was clarified from the flow measurement results that circumferential velocity component at the outlet of the outer rotor of contra-rotating ro- tors becomes larger than a conventional one. In the present paper, the performance of a conventional sirocco fan and a sirocco fan with contra-rotating rotors are shown and the internal flow field at the outlet of outer rotor of both cases is clarified. Then, the effect of different kind of contra-rotating rotors on the performance and internal flow field is investigated and the rotor design with higher performance would be discussed. 展开更多
关键词 Sirocco fan High pressure Contra-rotating rotors Slow angle Circular arc blade Aerofoil blade
原文传递
Unsteady Flow Condition of Contra-Rotating Small-Sized Axial Fan 被引量:1
4
作者 t.shigemitsu J.Fukutomi +2 位作者 Y.Okabe K.Iuchi H.Shimizu 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第6期495-502,共8页
Small-sized axial fans are used as air cooler for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotation... Small-sized axial fans are used as air cooler for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotational speed design is conducted,although,it causes the deterioration of efficiency and the increase of noise.Then,the adoption of contra-rotating rotors for the small-sized axial fan is proposed for the improvement of performance.In the case of contra-rotating rotors,it is necessary to design the rotor considering the unsteady flow condition of each front and rear rotor.In the present paper,the fan performance of the contra-rotating small-sized axial fan with 100mm diameter at a designed and a partial flow rates is shown,and the unsteady flow conditions at the inlet and the outlet of each front and rear rotor are clarified with unsteady numerical results.Furthermore,the relation between the performance and the unsteady flow condition of the contra-rotating small-sized axial fan is discussed and the methods to improve the performance are considered. 展开更多
关键词 Small-sized axial fan Contra-rotating rotor PERFORMANCE Unsteady flow condition
原文传递
上一页 1 下一页 到第