A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical cal...A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical calcu- lations of the vapor to coolant heat transfer have been performed for parametric values of fin height,fin spacing, vertical bundle depth and tubeside heat transfer coefficient.Three dielectric fluids (R-113,FC-72,and FC-87) at atmospheric pressure were selected as the working fluids.For a single tube with optimized fin geometry,the average heat flux increased in the order of FC-87,R-113 and FC-72.Both the optimum fin height and optimum fin spacing increased with increasing vertical bundle depth.展开更多
In this proceeding,we will first outline the experimental setup and main results of the most recent hypernuclear γ-ray spectroscopy experiment (KEK-E566) performed at KEK-PS K6 beam line. The main feature and charact...In this proceeding,we will first outline the experimental setup and main results of the most recent hypernuclear γ-ray spectroscopy experiment (KEK-E566) performed at KEK-PS K6 beam line. The main feature and characteristics of this type of research will be emphasised. After that,the approved experimental proposal (E13) at J-PARC facility will be introduced briefly.展开更多
文摘A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical calcu- lations of the vapor to coolant heat transfer have been performed for parametric values of fin height,fin spacing, vertical bundle depth and tubeside heat transfer coefficient.Three dielectric fluids (R-113,FC-72,and FC-87) at atmospheric pressure were selected as the working fluids.For a single tube with optimized fin geometry,the average heat flux increased in the order of FC-87,R-113 and FC-72.Both the optimum fin height and optimum fin spacing increased with increasing vertical bundle depth.
文摘In this proceeding,we will first outline the experimental setup and main results of the most recent hypernuclear γ-ray spectroscopy experiment (KEK-E566) performed at KEK-PS K6 beam line. The main feature and characteristics of this type of research will be emphasised. After that,the approved experimental proposal (E13) at J-PARC facility will be introduced briefly.