期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
电晕放电脉冲电流波形和相位分布的测量、分析与仿真(英文) 被引量:3
1
作者 suwarno 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2655-2663,共9页
Partial discharge(PD) is one of the most important phenomenon in high voltage insulations.In most cases, the appearance of partial discharges is related to insulation defects.Understanding partial discharges is import... Partial discharge(PD) is one of the most important phenomenon in high voltage insulations.In most cases, the appearance of partial discharges is related to insulation defects.Understanding partial discharges is important for diagnosis on insulation condition.Corona discharges appear when extremely high electric field appears on the conductor surface exceeding the electric field strength of the gas.The high electric field may occur at around protrusion with very sharp tip.This paper reported a holistic approach of corona discharge investigation.The needle-plane electrode system was used.The medium between the electrodes was air.The needle was made from steel with radius of curvature of 3μm(Ogura needle).Sinusoidal as well as triangular applied voltages were used.The waveform of the corona discharges was measured using a digital oscilloscope.The corona discharge pulses were measured using a phase-resolved PD measurement system.The system was able to measure the magnitude(q) and phase angle position(φ) of each PD pulses,as well as the number of discharge pulses(n).The role of applied voltage was investigated using phase-resolved analysis of corona discharge pulses through pulse sequence,pulse magnitude and pulse number analysis. Experimental results indicated that corona discharge current waveform was an impulse with rise time of about several ns and the impulse width of about 100 ns.The Fast Fourier Transform analysis indicated that the corona discharge current waveform had several spectrum peaks at frequency of 7.8 MHz,85.9 MHz,109.4 MHz and 195.3 MHz.The experimental results also showed that discharge pulses were concentrated around the peak of applied voltage for both sinusoidal and triangular voltages.The discharge magnitude,as well as its probability of occurrence,was strongly dependent on the instantaneous applied voltage.The shape ofφ-n,as well asφ-q-n PD patterns,were strongly reflected by the shape of applied voltage.In order to get deep understanding of the corona discharge,by utilizing results of the phase-resolved analysis,electrical equivalent circuits of corona discharges were proposed.The electrical equivalent circuit contained capacitances and a spark gap.For deeply understanding of PD phenomenon,computer simulation was done by using the proposed electrical equivalent circuits.The similarity of the measured and simulated PD patterns was assessed by comparing measured and simulated theφ-q-n andφ-n PD patterns.The results indicated that simulated PD patterns similar to those obtained from experiment. 展开更多
关键词 corona discharge phase-resolved analysis sinusoidal voltage triangular voltage
原文传递
Time Sequential and Phase-resolved Measurement and Analysis of Corona Discharge in Air and Streamer Discharge in Insulating Liquid 被引量:2
2
作者 suwarno 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2583-2588,共6页
Insulation is one of the most important parts in a high voltage equipment.There are gaseous,liquid and solid insulations which are commonly used.In a high voltage transformer for example the insulating materials are a... Insulation is one of the most important parts in a high voltage equipment.There are gaseous,liquid and solid insulations which are commonly used.In a high voltage transformer for example the insulating materials are all used.During operation of a high voltage equipment high electric stress may occur.Under extreme condition failure of the insulation may take place.Excessive electric field in air may cause corona discharges while in liquid insulation discharges may take place in the form of streamer.This paper reports experimental results on the corona and streamer discharges in air and silicone oil.The discharges were artificially generated around a needle tip in a needle-plane electrode system with gap length of 4 mm under sinusoidal and triangular voltages.The needle was made of steel with tip radius of 3 μm and curvature angle of 30°.The needle was made by Ogura Jewelry.The discharge pulses were measured using personal-computer based partial discharge(PD)measurement system with sensitivity of better than 0.5 pC.The system is able to measure discharge in time sequential.Phase-resolved analysis of the discharges was done to interpret the physical processes behind the discharges.The experimental results showed that corona discharges took place at negative half cycles.The discharges were concentrated around 270° of phase angle of applied voltage.The discharge magnitude and discharge number of corona clearly dependent on the instantaneous of applied voltage.These were strongly supported by the application of triangular voltage.Streamer discharges occurred at both positive and negative half cycles.The discharges pulses concentrated around the peak of applied voltage at phase angle of 90° and 270°.Experimental results under sinusoidal and triangular voltages revealed that streamer discharge magnitude as well as probability of occurrence was strongly dependent on the instantaneous applied voltage. 展开更多
关键词 空气 电晕放电 绝缘液体 流注放电 测量
在线阅读 下载PDF
Oviposition preference of swallowtail butterfly, Papilio polytes (Lepidoptera Papilionidae) on four Rutaceae (Sapindales) host plant species 被引量:2
3
作者 suwarno M.R. Che Salmah +1 位作者 Arshad Ali A. Abu Hassan 《Insect Science》 SCIE CAS CSCD 2010年第4期369-378,共10页
Oviposition preference and egg deposition site selection by the butterfly, Papilio polytes L. (Lepidoptera: Papilionidae) on four rutaceous host plants, Citrus aurantofolia (Christm.) Swing., Citrus hystrix DC., ... Oviposition preference and egg deposition site selection by the butterfly, Papilio polytes L. (Lepidoptera: Papilionidae) on four rutaceous host plants, Citrus aurantofolia (Christm.) Swing., Citrus hystrix DC., Citrus reticulata Blanco, and Murraya koenigii (L.) Sprengel, were assessed in field cages measuring 2 × 2 ×2 m. Simultaneous two-choice and four-choice oviposition tests of whole host plants were conducted. The mean total number of eggs laid per plant on C. reticulata in the two-choice test was significantly higher (P 〈 0.01) than those on C. aurantifolia, C. hystrix, andM. koenigii. Among the three other host plants, C. aurantifolia was preferred over C. hystrix, and M. koenigii (P 〈 0.01) and C. hystrix was preferred over M. koenigii (P 〈 0.01). In the four-choice test, C. reticulata was highly preferred and significantly different from C. hystrix and M. koenigii. However, no oviposition preference was detected with C. aurantifolia. Among the various plant parts in the two- and four-choice tests, eggs on leaves of each plant were the highest, followed by numbers on stems, and negligible numbers on pots. These numbers on leaves of C. reticulata and C. aurantifolia were not significantly different (P 〉 0.05), but differed significantly (P 〈 0.01) from those on leaves of C. hystrix and M. koenigii. The quantitative trend of egg-laying on stems was very similar to that observed for the leaves. Papilio polytes showed strong preference to lay eggs on the underside of leaves of all host plants than on the upper side or on the petiole. More eggs were laid on the upper side of each host plant than on its petiole. The four host plants in descending order of preference were C. reticulata 〉 C. aurantifolia 〉 C. hystrix 〉 M. koenigii. Although M. koenigii was the least preferred, it has the potential to serve as an alternative host plant for P. polytes which can be manipulated when necessary, to alleviate the infestation of this pest to the citrus industry. 展开更多
关键词 Citrus aurantifolia Citrus hystrix Citrus reticulata Murraya koenigii ovipo-sition preference Papilio polytes
原文传递
High voltage power transformer condition assessment considering the health index value and its decreasing rate 被引量:4
4
作者 Winanda Riga Tamma Rahman Azis Prasojo suwarno 《High Voltage》 SCIE EI 2021年第2期314-327,共14页
A health index method is a useful tool for the transformer assessment condition.This method has been used in several previous studies.However,most of them have not observed the health index decreasing rate as an aspec... A health index method is a useful tool for the transformer assessment condition.This method has been used in several previous studies.However,most of them have not observed the health index decreasing rate as an aspect to improve the transformer con-dition assessment.A health index method with different approaches is proposed,considering the values and decreasing rate to assess the transformer condition.Inspection data from in-service and out-of-service 150 kV power transformers provided by the Indonesian electric company are included.The correlation between operating age and Health Index value and Health Index decreasing rate was also observed.With increasing operation age,the Health Index value tends to decrease with a correlation coefficient R2 of 0.631.Further analysis was conducted to power transformers with historical data of 3 years or more,which showed that the tendency of the Health Index value decreasing rate is higher with older transformers.This paper also illustrates the Health Index analysis of 35 out-of-service transformers,resulting in a more suitable Health Index value compared to the previous approach.This study proposes the transformer risk assessment based on its health index value and the decreasing rate. 展开更多
关键词 VALUE POWER SERVICE
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部