Comparison of Cardiac Output Measurement by Noninvasive Method with Electrical Cardiometry and Invasive Method with Thermodilution Technique in Patients Undergoing Coronary Artery Bypass Grafting 被引量:2
1
作者 Randhir Singh Rajput Sambhunath Das +2 位作者 Sandeep Chauhan A. K. Bisoi sumit vasdev 《World Journal of Cardiovascular Surgery》 2014年第7期123-130,共8页
Objective: This study was conducted to compare the cardiac output by using Electrical Cardiometry (EC), a noninvasive method of continuous cardiac output monitoring during cardiac surgery with pulmonary artery cathete... Objective: This study was conducted to compare the cardiac output by using Electrical Cardiometry (EC), a noninvasive method of continuous cardiac output monitoring during cardiac surgery with pulmonary artery catheter (PAC) derived cardiac output. Design: Prospective observational clinical study. Setting: Cardiac surgery operating room of a tertiary care cardiac center. Participants: Twenty five patients undergoing coronary artery bypass surgery with cardiopulmonary bypass. Measurements and Main Results: A total of 150 double data of cardiac output were compared with Thermodilution Cardiac Output (TDCO) and Thoracic Electrical Bioimpedance (TEBCO). The TDCO value ranges from 1.8-6.9 litre·min-1 with a mean of 4.39 ± 1.16 litre·min-1 and TEBCO ranges from 1.8-7.1 litre·min-1 with a mean of 4.21 ± 1.16 litre·min-1. The averaged Bland-Altman analysis for TDCO and TEBCO revealed that a mean bias was 0.18 and limit of agreement was -1.25 - 0.89 litre·min-1 and the percentage error (PE) ranged from 22%-32%. The precision for the TDCO was measured to be ±16.2% and the precision for TEBCO was ±19.6%. Receiver Operating Characteristic (ROC) curve analysis between TDCO and TEBCO with a cutoff of 15% shows a sensitivity of 84% and specificity of 63 and area under ROC curve of 0.80. Mountain plot between TDCO and TEBCO shows that a median percentile is 0.25 and value of 97.5 percentile is 1.525. Conclusions: The present study indicates that the electric cardiometry device yields numerically comparable results to cardiac outputs derived from the PAC during the cardiac surgery. Therefore, electrical cardiometry can be used to evaluate haemodynamic variables with clinically acceptable accuracy, when invasive methods are to be avoided or not available. 展开更多
关键词 Electric Cardiometry THERMODILUTION Pulmonary Artery CATHETER Non INVASIVE Cardiac Output THORACIC ELECTRICAL BIOIMPEDANCE
暂未订购
The Variation in Plasma Cortisol Levels in Response to Anesthetic Induction with Etomidate or Ketamine in Children Undergoing Intracardiac Repair of Tetralogy of Fallot on Cardiopulmonary Bypass
2
作者 Anil K. Pandey Sandeep Chauhan +4 位作者 Neeti Makhija Usha Kiran sumit vasdev Sachin Talwar Ramakrishnan Lakshmy 《World Journal of Cardiovascular Surgery》 2012年第2期17-20,共4页
Objective: To compare the effect of a single induction dose of etomidate or ketamine on plasma cortisol levels in children with Tetralogy of Fallot (TOF) undergoing intra-cardiac repair on cardiopulmonary bypass (CPB)... Objective: To compare the effect of a single induction dose of etomidate or ketamine on plasma cortisol levels in children with Tetralogy of Fallot (TOF) undergoing intra-cardiac repair on cardiopulmonary bypass (CPB). Design: A prospective randomized trial. Setting: Cardiac center of a tertiary care hospital. Participants: Thirty children with TOF undergoing intra-cardiac repair on CPB. Interventions: After random allocation of the children into two groups, the children either received etomidate 0.2 mg/kg or ketamine 2 mg/kg intravenously for anesthetic induction along with fentanyl 2 mcg/kg and midazolam 100 mcg/kg. Endotracheal intubation was accomplished with rocuronium bromide in the dose of 1 mg/kg. Anesthesia was maintained with sevoflurane in air-oxygen, titrated to response and supplemental vecuronium bromide for muscle relaxation, fentanyl chloride for pain relief. Serum cortisol was measured on three occasions, at preinduction, at the end of surgery and at 24 hours postoperatively. Measurements and Main Results: Baseline plasma cortisol (Normal 5 - 25 mcg/dl) in the etomidate group (19.91 ± 3.51 mcg/dl) decreased significantly at the end of surgery (5.78 ± 2.0 mcg/dl) and rose to significantly higher than baseline values at 24 hours (27.31 ± 8.30 mcg/dl). The baseline cortisol levels in the ketamine group (20.91 ± 3.19 mcg/dl) increased significantly at the end of surgery (44.02 ± 5.49 mcg/dl) and remained significantly higher than baseline at 24hours (45.93 ± 3.05 mcg/dl). Plasma cortisol levels in the etomidate group at end of surgery, and at 24 hours post-operatively, were significantly lower than the ketamine group. Conclusions: This study shows that etomidate is a suitable and safe agent for suppression of the increase in serum cortisol associated with the use of CPB in children with TOF undergoing intra-cardiac repair. 展开更多
关键词 Serum CORTISOL Tetralogy of Fallot (TOF) ETOMIDATE