期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
EVA NEXUS-Phaco performance study
1
作者 Lukas Feldhaus Andreas Ohlmann +2 位作者 Stefan Kassumeh siegfried priglinger Wolfgang Mayer 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1447-1452,共6页
AIM:To investigate a novel phacoemulsification system“EVA NEXUS”(D.O.R.C.,Dutch Opthalmic Research Center)in comparison to the existing system“EVA”in clinical use.And to compare both phacoemulsification systems in... AIM:To investigate a novel phacoemulsification system“EVA NEXUS”(D.O.R.C.,Dutch Opthalmic Research Center)in comparison to the existing system“EVA”in clinical use.And to compare both phacoemulsification systems in terms of efficiency,safety and postoperative inflammatory activity.METHODS:In this study standardized cataract surgery was performed on both eyes of the study participant,using the“EVA system”(control group,n=20)on one eye and the“EVA NEXUS system”(intervention group,n=20)on the other eye.Only patients with cataract LOCS Grading 1-3 and no accompanying eye diseases were included in this study.A total of 20 patients were included in this study,with each treatment arm including 20 eyes.During surgery a 0.1 mL aqueous humor sample was collected 1min after phacoemulsification to measure the total prostaglanin E2 concentrations using an enzyme-linked immunosorbent assay.The endothelial cell count,visual and refractive outcomes,and anterior chamber flare were evaluated preoperatively,and 1d,1wk,and 3mo postoperatively.RESULTS:There were no statistically significant differences between both groups regarding intraoperative safety parameters including effective phacoemulsification time(P=0.904),balanced saline solution flow(P=0.701)and total surgery time(P=0.565).Postoperative prostaglandin E2 levels,anterior chamber flare as well as endothelial cell loss tended to be lower in the NEXUS-Group,however not being statistically significant(P=0.718;0.164;0.486).Both systems provided similar clinical outcomes,regarding best corrected visual acuity and refractive parameters,showing no statistically significant differences between both groups.CONCLUSION:Both systems show a high level of safety and efficency with similar results in terms of safety parameters including postoperative inflammatory activity and endothelial cell loss as well as visual and refractive outcomes.Although statistically not significant,the EVA NEXUS system tends to cause less postoperative inflammation with lower prostaglandin E2 levels and lower anterior chamber flare values. 展开更多
关键词 cataract surgery PHACOEMULSIFICATION FLUIDICS instrument
原文传递
Ecstasy-induced optic disc swelling and consequent visual loss
2
作者 Michaela Ramsauer Stephan Thurau +1 位作者 siegfried priglinger Efstathios Vounotrypidis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第3期520-522,共3页
Dear Editor,We present the first reported case of unilateral optic disc swelling with subsequent persistent loss of vision triggered by ecstasy consumption in the case of a young man.Ecstasy is one of the most commonl... Dear Editor,We present the first reported case of unilateral optic disc swelling with subsequent persistent loss of vision triggered by ecstasy consumption in the case of a young man.Ecstasy is one of the most commonly consumed recreational drugs among young adults.Its main constituent and active substance is 3,4-methylenedioxymethamphetamine(MDMA). 展开更多
关键词 ECSTASY optic disc swelling visual loss
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部