期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Current trends in three-dimensional visualization and real-time navigation as well as robot-assisted technologies in hepatobiliary surgery 被引量:14
1
作者 Yun Wang Di Cao +3 位作者 si-lin chen Yu-Mei Li Yun-Wen Zheng Nobuhiro Ohkohchi 《World Journal of Gastrointestinal Surgery》 SCIE 2021年第9期904-922,共19页
With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary su... With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary surgery,traditional preoperative imaging techniques such as computed tomography and magnetic resonance imaging cannot meet the need for identification of fine anatomical regions.Imaging-based three-dimensional(3D)reconstruction,virtual simulation of surgery and 3D printing optimize the surgical plan through preoperative assessment,improving the controllability and safety of intraoperative operations,and in difficult-to-reach areas of the posterior and superior liver,assistive robots reproduce the surgeon’s natural movements with stable cameras,reducing natural vibrations.Electromagnetic navigation in abdominal surgery solves the problem of conventional surgery still relying on direct visual observation or preoperative image assessment.We summarize and compare these recent trends in digital medical solutions for the future development and refinement of digital medicine in hepatobiliary surgery. 展开更多
关键词 Hepatobiliary surgery Three-dimensional visualization Three-dimensional printing Electromagnetic tracking Real-time navigation Robot-assisted surgery
暂未订购
Heart rate-adjusted PR as a prognostic marker of long-term ventricular arrhythmias and cardiac death in ICD/CRT-D recipients 被引量:2
2
作者 Yu-Qiu LI Shuang ZHAO +8 位作者 Ke-Ping chen Yang-Gang SU Wei HUA si-lin chen Zhao-Guang LIANG Wei XU Yan DAI Xiao-Han FAN Shu ZHANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第3期259-264,共6页
Objective To evaluate the PR to RR interval ratio (PR/RR,heart rate-adjusted PR) as a prognostic marker for long-term ventricular arrhythmias and cardiac death in patients with implantable cardioverter defibrillator (... Objective To evaluate the PR to RR interval ratio (PR/RR,heart rate-adjusted PR) as a prognostic marker for long-term ventricular arrhythmias and cardiac death in patients with implantable cardioverter defibrillator (ICDs) and cardiac resynchronization therapy with defibrillators (CRT-D).Methods We retrospectively analyzed data from 428 patients who had an ICD/CRT-D equipped with home monitoring.Baseline PR and RR interval data prior to ICD/CRT-D implantation were collected from standard 12-lead electrocardiograph,and the PR/RR was calculated.The primary endpoint was appropriate ICD/CRT-D treatment of ventricular arrhythmias (VAs),and the secondary endpoint was cardiac death.Results During a mean follow-up period of 38.8 ± 10.6 months,197 patients (46%) experienced VAs,and 47 patients (11%) experienced cardiac death.The overall PR interval was 160 ± 40 ms,and the RR interval was 866 ± 124 ms.Based on the receiver operating characteristic curve,a cut-off value of 18.5% for the PR/RR was identified to predict VAs.A PR/RR ≥ 18.5% was associated with an increased risk of VAs [hazard ratio (HR)= 2.243,95% confidence interval (CI)= 1.665–3.022,P < 0.001) and cardiac death (HR = 2.358,95%CI = 1.240–4.483,P = 0.009) in an unadjusted analysis.After adjustment in a multivariate Cox model,the relationship remained significant among PR/RR ≥ 18.5%,VAs (HR = 2.230,95%CI = 1.555–2.825,P < 0.001) and cardiac death (HR = 2.105,95%CI = 1.101–4.025,P = 0.024.Conclusions A PR/RR ≥ 18.5% at baseline can serve as a predictor of future VAs and cardiac death in ICD/CRT-D recipients. 展开更多
关键词 Implantable cardioverter DEFIBRILLATOR PR INTERVAL RR INTERVAL VENTRICULAR ARRHYTHMIAS
暂未订购
Ground state of Rydberg-dressed Bose gas confined in a toroidal trap
3
作者 Lin-Xue Wang Hong-Li Yang +3 位作者 Hui Liu si-lin chen Ya-Jun Wang Xiao-Fei Zhang 《Communications in Theoretical Physics》 SCIE CAS CSCD 2024年第1期29-35,共7页
The experimental realization of Rydberg dressing technology in ultracold atomic systems provides another superior platform for studying novel states of matter and macroscopic quantum phenomena.In this work,based on th... The experimental realization of Rydberg dressing technology in ultracold atomic systems provides another superior platform for studying novel states of matter and macroscopic quantum phenomena.In this work,based on the mean-field theory,we have investigated the ground-state phases of a two-component Bose–Einstein condensate with Rydberg interaction and confined in a toroidal trap.The effects of the Rydberg interaction and external potential,especially the Rydberg blockade radius,on the ground-state structure of such a system have been investigated in full parameter space.Our results show that the Rydberg blockade radius,which can be regarded as another controllable parameter,can be used to obtain a variety of ground-state phases.More interestingly,it is found that for weak Rydberg interactions,the Rydberg blockade radius breaks the spontaneous rotational symmetry of the system,leading to the formation of a discrete unit cell structure.For strongly interacting cases,it can be used to realize different orders of discrete rotational symmetry breaking. 展开更多
关键词 Bose-Einstein condensate Rydberg dressing toroidal trap
原文传递
Dipolar Bose gas with SU(3)spin-orbit coupling held under a toroidal trap
4
作者 Fang Wang Jia Liu +3 位作者 si-lin chen Lin Wen Xue-Ying Yang Xiao-Fei Zhang 《Frontiers of physics》 2025年第2期191-200,共10页
We consider a dipolar spin-1 Bose gas with SU(3)spin-orbit coupling trapped in a two-dimensional toroidal trap.Due to the combined effects of SU(3)spin-orbit coupling,dipole-dipole interaction,and spin-exchange intera... We consider a dipolar spin-1 Bose gas with SU(3)spin-orbit coupling trapped in a two-dimensional toroidal trap.Due to the combined effects of SU(3)spin-orbit coupling,dipole-dipole interaction,and spin-exchange interaction,the system exhibits a rich variety of ground-state phases and topological defects,including modified stripe,azimuthal distributed petal and triangular lattice,double-quantum spin vortices,and so on.In particular,by studying the spin texture of such a system,it is found that the formation and transformation between meron and skyrmion topological spin textures can be realized by a choice of dipole-dipole interaction,SU(3)spin-orbit coupling,and spin-exchange interaction.We also give an experimental protocol to observe such novel states within current experimental capacity. 展开更多
关键词 Bose-Einstein condensate spin-orbit coupling dipolar condensate quantum vortex
原文传递
Whole breast ultrafractionation radiotherapy after breast-conserving surgery in early breast cancer: A single-center, prospective, observational study from China
5
作者 Rui-Zhi Zhao cheng Huang +12 位作者 Tian-Lan Tang Gui-Qing Shi si-lin chen Yu-Ping Lin Ying Wang Liu-Qing Jiang Jin-Hua chen Chun-Sen Xu Fang-Meng Fu Zhong-Hua Han Shun-Guo Lin Chuan Wang Yong Yang 《Malignancy Spectrum》 2024年第2期113-122,共10页
Objective:This single-center,prospective,observational study was designed to investigate the toxicities,patient-reported outcome(PRO),and dosimetric analysis of whole breast ultrafractionation radiotherapy(RT)after br... Objective:This single-center,prospective,observational study was designed to investigate the toxicities,patient-reported outcome(PRO),and dosimetric analysis of whole breast ultrafractionation radiotherapy(RT)after breast-conserving surgery(BCS)in early breast cancer(BC).Patients and methods:Patients diagnosed with BC stage I,II and treated with BCS were enrolled.A dose of 26 Gray(Gy)in five fractions was prescribed to the whole breast and tumor bed.Clinical endpoints included toxicities,PRO,and dosimetric analysis.PRO was measured by the European Organization for Research and Treatment of Cancer general quality of life questionnaire(EORTC QLQ-C30)and the BC-specific questionnaire(EORTC QLQ-BR23)questionnaires.Results:Between January 2022 and June 2023,62 female patients were enrolled.The median age was 45 years.Most patients(83.9%)were diagnosed with pathological stage I disease.The median planning target volume(PTV)was 456.4 mL.The minimum,maximum,and mean doses,and D95(dose of PTV irradiated volume more than 95%)to PTV were 20.2,28.8,27.2,and 26.3 Gy,respectively.The median mean lung dose and percentage lung volume receiving 8 Gy(V8)were 3.6 Gy and 13.4%,respectively.The median mean heart dose,V1.5(percentage of organ volume irradiated with 1.5 Gy or higher),and V7(percentage of organ volume irradiated with 7 Gy or higher)were 0.6 Gy,6.8%,and 0.4%,respectively.Cosmetic effects before RT showed no obvious differences compared to that post RT.No toxicities of grade 3 or higher occurred.Five patients had asymptomatic radiation pneumonia(grade 1),and 12 patients had radiation dermatitis(grade 1).No factor was significantly related to radiation dermatitis or radiation pneumonia.For the EORTC QLQ-C30 and QLQ-BR23 questionnaires,all function and symptom scores before RT had no significant differences compared with that after RT,1−2 months after RT,and 3−4 months after RT.Ultrafractionation RT did not worsen PRO.The 1-year crude local control was 100%.Conclusion:Whole breast ultrafractionation RT after BCS in early BC has no severe toxicities and does not affect PRO.These results need to be further validated with a longer follow-up and a larger sample size. 展开更多
关键词 ultrafractionation RADIOTHERAPY BREAST cancer BREAST-CONSERVING surgery TOXICITIES patient-reported outcome
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部