AIM: To prospectively evaluate the indications, methodology, safety, and clinical impact of double-balloon endoscopy. METHODS: A total of 60 patients with suspected or documented small- or large-bowel diseases were ...AIM: To prospectively evaluate the indications, methodology, safety, and clinical impact of double-balloon endoscopy. METHODS: A total of 60 patients with suspected or documented small- or large-bowel diseases were investigated by double balloon endoscopy. A total of 103 procedures were performed (42 from the oral route, 60 from the anal route, and 1 from the stoma route). The main outcome measurements were the time of insertion and the entire examination, complications, diagnostic yields, and the ability to successfully perform treatment. RESULTS: Observation of the entire small intestine was possible in 10 (40%) of 25 patients with total enteroscopy. The median insertion time was 122 min (range, 74-199 min). Observation of the entire colon was possible in 13 (93%) of 14 patients at"cer failure of total colonoscopy using a conventional colonoscope. Small-intestine abnormalities were found in 20 (43%) of 46 patients with indications of suspected or documented small bowel diseases, obscure GI tract bleeding, or a history of ileus. Endoscopic procedures including tattooing (n = 33), bite biopsy (n = 17), radiographic examination (n = 7), EUS (n = 5), hemostasis (n = 1), polypectomy (n = 5), balloon dilatation (n = 1), endoscopic mucosal resection (n = 1) and lithotripsy (n = 1) were all successfully performed. No relevant technical problems or severe complications were encountered. CONCLUSION: Double balloon endoscopy is a feasible technique that allows adequate small and large bowel examination and potentially various endoscopic procedures of small-intestinal lesions. It is safe, useful, and also provides a high clinical impact.展开更多
AIM: To evaluate whether an automatically controlled cut system (endocut mode) could reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventiona...AIM: To evaluate whether an automatically controlled cut system (endocut mode) could reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode. METHODS: From January 2001 to October 2003, 134 patients with choledocholithiasis were assigned to either endocut mode group or conventional blended cut mode group at the time of sphincterotomy. The two groups were retrospectively compared for the complications after EST and serum amylase level before and 24 h after the procedure. RESULTS: Of the 134 patients treated, 79 were assigned to conventional blended cut mode group and 55 to endocut mode group. There was no significant difference in age, sex, and serum amylase level before EST between the two groups. Complications were found in 5 patients of the endocut mode group (9%): hyperamylasemia (5 times higher than normal) in 4 and moderate pancreatitis in 1. Complications were found in 13 patients of the conventional blended cut mode group (16%): hyperamylasemia in 12 and moderate pancreatitis in 1. Serum amylase levels were elevated in both groups 24 h after EST (P〈0.02). The average serum amylase level 24 h after EST in the conventional blended cut mode group was significantly higher than that in the endocut mode group (P〈 0.05). CONCLUSION: Endocut mode offers a safety advantage over conventional blended cut mode for pancreatitis after EST by reducing hyperamylasemia.展开更多
Endoscopic submucosal dissection (ESD) with a knife is a technically demanding procedure a ssociated with ahigh complication rate. The shortcomings of this meth-od are the inability to fix the knife to the target le...Endoscopic submucosal dissection (ESD) with a knife is a technically demanding procedure a ssociated with ahigh complication rate. The shortcomings of this meth-od are the inability to fix the knife to the target lesion,and compression of the lesion. These can lead to major complications such as perforation and bleeding. To reduce the risk of complications related to ESD, we developed a new grasping type scissors forceps (GSF),which can grasp and incise the targeted tissue using electrosurgical current. Colonoscopy on a 55-year-old woman revealed a 10-ram rectal submucosal nodule.The histological diagnosis of the specimen obtained by biopsy was carcinoid tumor. Endoscopic ultrasonog-raphy demonstrated a hypoechoic solid tumor limitedto the submucosa without lymph node involvement. Itwas safely and accurately resected without unexpectedincision by ESD using a GSF. No delayed hemorrhage or perforation occurred. Histological examination confirmed the carcinoid tumor was completely excisedwith negative resection margin.展开更多
文摘AIM: To prospectively evaluate the indications, methodology, safety, and clinical impact of double-balloon endoscopy. METHODS: A total of 60 patients with suspected or documented small- or large-bowel diseases were investigated by double balloon endoscopy. A total of 103 procedures were performed (42 from the oral route, 60 from the anal route, and 1 from the stoma route). The main outcome measurements were the time of insertion and the entire examination, complications, diagnostic yields, and the ability to successfully perform treatment. RESULTS: Observation of the entire small intestine was possible in 10 (40%) of 25 patients with total enteroscopy. The median insertion time was 122 min (range, 74-199 min). Observation of the entire colon was possible in 13 (93%) of 14 patients at"cer failure of total colonoscopy using a conventional colonoscope. Small-intestine abnormalities were found in 20 (43%) of 46 patients with indications of suspected or documented small bowel diseases, obscure GI tract bleeding, or a history of ileus. Endoscopic procedures including tattooing (n = 33), bite biopsy (n = 17), radiographic examination (n = 7), EUS (n = 5), hemostasis (n = 1), polypectomy (n = 5), balloon dilatation (n = 1), endoscopic mucosal resection (n = 1) and lithotripsy (n = 1) were all successfully performed. No relevant technical problems or severe complications were encountered. CONCLUSION: Double balloon endoscopy is a feasible technique that allows adequate small and large bowel examination and potentially various endoscopic procedures of small-intestinal lesions. It is safe, useful, and also provides a high clinical impact.
文摘AIM: To evaluate whether an automatically controlled cut system (endocut mode) could reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode. METHODS: From January 2001 to October 2003, 134 patients with choledocholithiasis were assigned to either endocut mode group or conventional blended cut mode group at the time of sphincterotomy. The two groups were retrospectively compared for the complications after EST and serum amylase level before and 24 h after the procedure. RESULTS: Of the 134 patients treated, 79 were assigned to conventional blended cut mode group and 55 to endocut mode group. There was no significant difference in age, sex, and serum amylase level before EST between the two groups. Complications were found in 5 patients of the endocut mode group (9%): hyperamylasemia (5 times higher than normal) in 4 and moderate pancreatitis in 1. Complications were found in 13 patients of the conventional blended cut mode group (16%): hyperamylasemia in 12 and moderate pancreatitis in 1. Serum amylase levels were elevated in both groups 24 h after EST (P〈0.02). The average serum amylase level 24 h after EST in the conventional blended cut mode group was significantly higher than that in the endocut mode group (P〈 0.05). CONCLUSION: Endocut mode offers a safety advantage over conventional blended cut mode for pancreatitis after EST by reducing hyperamylasemia.
文摘Endoscopic submucosal dissection (ESD) with a knife is a technically demanding procedure a ssociated with ahigh complication rate. The shortcomings of this meth-od are the inability to fix the knife to the target lesion,and compression of the lesion. These can lead to major complications such as perforation and bleeding. To reduce the risk of complications related to ESD, we developed a new grasping type scissors forceps (GSF),which can grasp and incise the targeted tissue using electrosurgical current. Colonoscopy on a 55-year-old woman revealed a 10-ram rectal submucosal nodule.The histological diagnosis of the specimen obtained by biopsy was carcinoid tumor. Endoscopic ultrasonog-raphy demonstrated a hypoechoic solid tumor limitedto the submucosa without lymph node involvement. Itwas safely and accurately resected without unexpectedincision by ESD using a GSF. No delayed hemorrhage or perforation occurred. Histological examination confirmed the carcinoid tumor was completely excisedwith negative resection margin.