Dyed polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA or poly(vinyl butyral) PVB containing quinaldine red (QR) on a horizontal glass plate, are useful as routine h...Dyed polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA or poly(vinyl butyral) PVB containing quinaldine red (QR) on a horizontal glass plate, are useful as routine high-dose dosimeters. These flexible plastic film dosimeters are bleached when exposed to gamma rays. The response of these dosimeters depends on the concentration of QR and the polymer material. The radiation chemical yield (G-value) of both PVA and PVB dyed films was calculated and was found to increase with increasing dye concentration. The effect of relative humidity during irradiation as well as pre- and post-irradiation storage, on the response of the films is examined. These films are not affected by humidity change in the intermediate range of 10% - 50%.展开更多
Ferrotitanium alloy polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA containing ferrotitanium alloy on a horizontal glass plate, are useful as routine high-dose dos...Ferrotitanium alloy polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA containing ferrotitanium alloy on a horizontal glass plate, are useful as routine high-dose dosimeters. These flexible plastic film dosimeters have pale yellow color, are bleached when exposed to gamma rays. The chemical composition of alloy was determined by EDX, and structure of alloy was determined by XRD. The response of these dosimeters depends on the concentration of alloy. The energy band gap Eg was calculated and the effect of gamma radiation on its value was determined. The optical absorption spectra showed that the absorption mechanism is an indirect allowed transition which found that energy band gap Eg decreases after irradiation. The response of these films has negligible humidity effects on the range of relative humidity from 0 to 100%. And also, it exhibits good preand post-irradiation stability in dark and light.展开更多
DL-ornithine hydrochloride rods (3 ×10 mm) were studied to be a radiation sensitive material for EPR dosimetry. The rods have specified EPR signal developed under irradiation and its intensity increases with the ...DL-ornithine hydrochloride rods (3 ×10 mm) were studied to be a radiation sensitive material for EPR dosimetry. The rods have specified EPR signal developed under irradiation and its intensity increases with the increase in absorbed dose. The intensity also affected by the concentration of DL-ornithine in the rods. The prepared rods can be used in the dose range from 0.5 - 50 kGy. The obtained number of free radicals per 100 eV (G value) was found to be 0.3551 ± 0.0333. The hyperfine (hf) coupling constant is 2.325 mT at g-factor 2.033. The rods have the advantage of negligible humidity effects during irradiation. The pre and post- irradiation stability was found to be satisfactory.展开更多
文摘Dyed polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA or poly(vinyl butyral) PVB containing quinaldine red (QR) on a horizontal glass plate, are useful as routine high-dose dosimeters. These flexible plastic film dosimeters are bleached when exposed to gamma rays. The response of these dosimeters depends on the concentration of QR and the polymer material. The radiation chemical yield (G-value) of both PVA and PVB dyed films was calculated and was found to increase with increasing dye concentration. The effect of relative humidity during irradiation as well as pre- and post-irradiation storage, on the response of the films is examined. These films are not affected by humidity change in the intermediate range of 10% - 50%.
文摘Ferrotitanium alloy polymer films, prepared by a simple technique of casting aqueous solutions of poly(vinyl alcohol) PVA containing ferrotitanium alloy on a horizontal glass plate, are useful as routine high-dose dosimeters. These flexible plastic film dosimeters have pale yellow color, are bleached when exposed to gamma rays. The chemical composition of alloy was determined by EDX, and structure of alloy was determined by XRD. The response of these dosimeters depends on the concentration of alloy. The energy band gap Eg was calculated and the effect of gamma radiation on its value was determined. The optical absorption spectra showed that the absorption mechanism is an indirect allowed transition which found that energy band gap Eg decreases after irradiation. The response of these films has negligible humidity effects on the range of relative humidity from 0 to 100%. And also, it exhibits good preand post-irradiation stability in dark and light.
文摘DL-ornithine hydrochloride rods (3 ×10 mm) were studied to be a radiation sensitive material for EPR dosimetry. The rods have specified EPR signal developed under irradiation and its intensity increases with the increase in absorbed dose. The intensity also affected by the concentration of DL-ornithine in the rods. The prepared rods can be used in the dose range from 0.5 - 50 kGy. The obtained number of free radicals per 100 eV (G value) was found to be 0.3551 ± 0.0333. The hyperfine (hf) coupling constant is 2.325 mT at g-factor 2.033. The rods have the advantage of negligible humidity effects during irradiation. The pre and post- irradiation stability was found to be satisfactory.