The Monte Carlo method is used to simulate the beam optics of the WS beam line of RCNP, Osaka University in order to know the effect of collimators on the beam line to control the beam spot. According to the simulatio...The Monte Carlo method is used to simulate the beam optics of the WS beam line of RCNP, Osaka University in order to know the effect of collimators on the beam line to control the beam spot. According to the simulation, we do not need to use the collimator to cut the beam and the beam angular resolution can be better than 0.05° in achromatic mode. In the present paper, the actual beam condition during the beam adjustment is listed. The accelerator can provide a 12C beam in achromatic mode and the angular resolution σ=0.7775 mrad±0.0030 mrad.展开更多
In order to further obtain the information of three-body force (TBF) from 200-400 MeV/u ^12C+^12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition...In order to further obtain the information of three-body force (TBF) from 200-400 MeV/u ^12C+^12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition of the Radioactive Ion Beam Factory (RIBF)-SHARAQ facility, a simulation is given to find a compromise between the better energy and angular resolutions, and higher yield by optimizing the target thickness, beam transport mode, beam intensity and angular step. From the simulation, we found that the beam quality mainly limits the improvements of energy and angular resolutions. A beam tracking system as well as a lateral and angular dispersion- matching technique axe adopted to reduce the influence of beam quality. According to the two angular settings of SHARAQ as well as the expected cross sections on the basis of the theoretical model, the energy and angular resolutions, and statistical accuracy are estimated.展开更多
基金Supported by National Nature Science Foundation of China(11035007,11235002,11175011)State Key Laboratory of Software Development Environment(SKLSDE-2014ZX-08 as well as by the Key Laboratory of High Precision Nuclear Spectroscopy,Institute of Modern Physics,Chinese Academy of Sciences.)
文摘The Monte Carlo method is used to simulate the beam optics of the WS beam line of RCNP, Osaka University in order to know the effect of collimators on the beam line to control the beam spot. According to the simulation, we do not need to use the collimator to cut the beam and the beam angular resolution can be better than 0.05° in achromatic mode. In the present paper, the actual beam condition during the beam adjustment is listed. The accelerator can provide a 12C beam in achromatic mode and the angular resolution σ=0.7775 mrad±0.0030 mrad.
基金Supported by National Nature Science Foundation of China(11035007,11235002,11175011)
文摘In order to further obtain the information of three-body force (TBF) from 200-400 MeV/u ^12C+^12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition of the Radioactive Ion Beam Factory (RIBF)-SHARAQ facility, a simulation is given to find a compromise between the better energy and angular resolutions, and higher yield by optimizing the target thickness, beam transport mode, beam intensity and angular step. From the simulation, we found that the beam quality mainly limits the improvements of energy and angular resolutions. A beam tracking system as well as a lateral and angular dispersion- matching technique axe adopted to reduce the influence of beam quality. According to the two angular settings of SHARAQ as well as the expected cross sections on the basis of the theoretical model, the energy and angular resolutions, and statistical accuracy are estimated.