Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous Wind Generators
1
作者 Q.L. Deng s.d. huang F. Xiao 《Journal of Energy and Power Engineering》 2010年第7期42-47,共6页
In order to reduce the cogging torque, this paper investigates the influence of some parameters on the cogging torque developed by directly driven permanent magnet synchronous wind generators. Based on the remanent ma... In order to reduce the cogging torque, this paper investigates the influence of some parameters on the cogging torque developed by directly driven permanent magnet synchronous wind generators. Based on the remanent magnetic flux densities, the cogging torque is computed by using finite element method. It is shown that many parameters have influence on cogging torque and the slot and pole number combination has a significant effect on cogging torque. A simple factor has been introduced to indicate the effect of the slot and pole number combination. Some practical experience to reduce the cogging torque was applied to 2 MW three phase permanent magnet synchronous generator at rated speed of 37.5 rpm for wind energy conversion. The simulation and experiment results verify the effect of the proposed method. 展开更多
关键词 Cogging torque permanent magnet synchronous generator electric machine design.