A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detecto...A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detectors and twenty fast Ce-doped Lanthanum Bromide[LaBr_(3)(Ce)]detectors shielded with CsI(Tl).HALIMA is further complemented by two ancillary detector systems:fission fragment(FF)detectors and β detectors.This configuration enables precise sub-nanosecond lifetime measurements using the fourfold FF/β-Ge-LaBr_(3)(Ce)-LaBr_(3)(Ce)coincidence technique.The performance and specifications of the detectors,associated electronics,and the data acquisition system are presented in detail.The advantage of FF selectivity is emphasized,which significantly enhances sensitivity to specific fission channels.Using this approach,the lifetimes of the nuclear excited states populated in the spontaneous fission of^(252)Cf were measured,showing good agreement with the established literature values.展开更多
With the aim of simulating the harsh temperature condition of space, a thallium-activated cesium iodide crystal(CsI:Tl) detector readout with a PIN photodiode(CsI:Tl(PD)) and with a silicon photomultiplier(CsI:Tl(SiPM...With the aim of simulating the harsh temperature condition of space, a thallium-activated cesium iodide crystal(CsI:Tl) detector readout with a PIN photodiode(CsI:Tl(PD)) and with a silicon photomultiplier(CsI:Tl(SiPM)) is investigated over a temperature range from-40 to 40 ℃. With the increase in temperature, the output signal increases by ~ 24% with CsI:Tl(PD) and decreases by ~69% with CsI:Tl(SiPM). To reduce the effect of temperature in outer space, a method of bias voltage compensation is adopted for CsI:Tl(SiPM). Our study demonstrates that after correcting the temperature the variation in the analog-to-digital converter's amplitude is< 3%.展开更多
In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a...In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.展开更多
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,...A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.展开更多
基金supported by the National Natural Science Foundation of China(Nos.12275321,12121005,12475129,and 12335009)the Natural Science Foundation of Guangdong Province,China(No.2025A1515012112)+5 种基金the International Atomic Energy Agency Coordinated Research Project F41034(No.28649)the computational resources from Sun Yat-sen University the National Supercomputer Center in Guangzhouthe Open Project of Guangxi Key Laboratory of Nuclear Physics and Nuclear Technology(No.NLK2023-08)the Central Government Guidance Funds for Local Scientific and Technological Development,China(No.Guike ZY22096024)the Guangdong Major Project of Basic and Applied Basic Research(No.2021B0301030006)Young Scientists Fund of the National Natural Science Foundation of China(No.12405144)the National Key Research and Development Program(MOST 2022YFA1602304).
文摘A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detectors and twenty fast Ce-doped Lanthanum Bromide[LaBr_(3)(Ce)]detectors shielded with CsI(Tl).HALIMA is further complemented by two ancillary detector systems:fission fragment(FF)detectors and β detectors.This configuration enables precise sub-nanosecond lifetime measurements using the fourfold FF/β-Ge-LaBr_(3)(Ce)-LaBr_(3)(Ce)coincidence technique.The performance and specifications of the detectors,associated electronics,and the data acquisition system are presented in detail.The advantage of FF selectivity is emphasized,which significantly enhances sensitivity to specific fission channels.Using this approach,the lifetimes of the nuclear excited states populated in the spontaneous fission of^(252)Cf were measured,showing good agreement with the established literature values.
基金supported by the National Natural Science Foundation of China(Nos.11575257,11575269,and U1732134)the Youth Innovation Promotion Association of the Chinese Academy of Science(No.2015342)
文摘With the aim of simulating the harsh temperature condition of space, a thallium-activated cesium iodide crystal(CsI:Tl) detector readout with a PIN photodiode(CsI:Tl(PD)) and with a silicon photomultiplier(CsI:Tl(SiPM)) is investigated over a temperature range from-40 to 40 ℃. With the increase in temperature, the output signal increases by ~ 24% with CsI:Tl(PD) and decreases by ~69% with CsI:Tl(SiPM). To reduce the effect of temperature in outer space, a method of bias voltage compensation is adopted for CsI:Tl(SiPM). Our study demonstrates that after correcting the temperature the variation in the analog-to-digital converter's amplitude is< 3%.
基金supported by the National Natural Science Foundation of China (Nos.12275007, U1867214, 11775004)the funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University,China (No. NPT2021ZZ01)funding from heavy Ion Research Facility,Lanzhou,China (No. HIR2021PY002)。
文摘In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.
基金supported by the Major program of Natural Science Foundation of Shandong Province(No.ZR2020ZD30)the National Natural Science Foundation of China(Nos.11775133,U2167202,U1432119).
文摘A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.