Fault-related resonance frequency band extraction-based demodulation methods are widely used for bearing diagnostics.However,due to the high peaks of strong gear meshing interference,the classical band selection metho...Fault-related resonance frequency band extraction-based demodulation methods are widely used for bearing diagnostics.However,due to the high peaks of strong gear meshing interference,the classical band selection methods have poor performance and cannot work well for bearing fault type detection.As such,the CVRgram-based bearing fault diagnosis method is proposed in this paper.In the proposed method,inspired by the conditional variance(CV)index and root mean square(RMS),a novel index,named the CV/root mean square(CVR),is first proposed.The CVR index has high robustness for the interference of non-Gaussian or Gaussian noise and has the ability to determine the center frequency of the weak bearing fault-related resonance frequency band under strong interference.Secondly,motived by the Kurtogram,the CVRgram algorithm is developed for adaptively determining the optimal filtering parameters.Finally,the CVRgram-based bearing fault diagnosis method under strong gear meshing interference is proposed.The performance of the CVRgram-based method is verified by both the simulation signal and the experiment signal.The comparison analysis with the Kurtogram,Protrugram,and CVgram-based method shows that the proposed technique has a much better ability for bearing fault detection under strong noise interference.展开更多
A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC s...A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC strategy optimizes the power distribution among the WFs to minimize the power losses of the AC TS while tracking the active power reference from the transmission system operator(TSO),and minimizes the voltage deviation of the buses inside the WF from the rated voltage as well as the power losses of the WF collection system.The optimal power flow(OPF)of the TS is relaxed by using the semidefinite programming(SDP)relaxation while the branch flow model is used to model the WF collection system.In the DARPC strategy,the large-scale strongly-coupled optimization problem is decomposed by using the ADMM,which is solved in the regional TS controller and WF controllers in parallel without loss of the global optimality.The boundary information is exchanged between the regional TS controller and WF controllers.Compared with the conventional OPF method of the TS with WFs,the optimality and accuracy of the system operation can be improved.Moreover,the proposed strategy efficiently reduces the computation burden of the TS controller and eliminates the need of a central controller.The protection of the information privacy can be enhanced.A modified IEEE 9-bus system with two WFs consisting of 64 wind turbines(WTs)is used to validate the proposed DARPC strategy.展开更多
基金supported by the National Natural Science Foundation of China (Grant Nos.52075008,51905292)。
文摘Fault-related resonance frequency band extraction-based demodulation methods are widely used for bearing diagnostics.However,due to the high peaks of strong gear meshing interference,the classical band selection methods have poor performance and cannot work well for bearing fault type detection.As such,the CVRgram-based bearing fault diagnosis method is proposed in this paper.In the proposed method,inspired by the conditional variance(CV)index and root mean square(RMS),a novel index,named the CV/root mean square(CVR),is first proposed.The CVR index has high robustness for the interference of non-Gaussian or Gaussian noise and has the ability to determine the center frequency of the weak bearing fault-related resonance frequency band under strong interference.Secondly,motived by the Kurtogram,the CVRgram algorithm is developed for adaptively determining the optimal filtering parameters.Finally,the CVRgram-based bearing fault diagnosis method under strong gear meshing interference is proposed.The performance of the CVRgram-based method is verified by both the simulation signal and the experiment signal.The comparison analysis with the Kurtogram,Protrugram,and CVgram-based method shows that the proposed technique has a much better ability for bearing fault detection under strong noise interference.
基金supported in part by Technical University of Denmark(DTU)in part by China Scholarship Council(No.201806130202)。
文摘A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC strategy optimizes the power distribution among the WFs to minimize the power losses of the AC TS while tracking the active power reference from the transmission system operator(TSO),and minimizes the voltage deviation of the buses inside the WF from the rated voltage as well as the power losses of the WF collection system.The optimal power flow(OPF)of the TS is relaxed by using the semidefinite programming(SDP)relaxation while the branch flow model is used to model the WF collection system.In the DARPC strategy,the large-scale strongly-coupled optimization problem is decomposed by using the ADMM,which is solved in the regional TS controller and WF controllers in parallel without loss of the global optimality.The boundary information is exchanged between the regional TS controller and WF controllers.Compared with the conventional OPF method of the TS with WFs,the optimality and accuracy of the system operation can be improved.Moreover,the proposed strategy efficiently reduces the computation burden of the TS controller and eliminates the need of a central controller.The protection of the information privacy can be enhanced.A modified IEEE 9-bus system with two WFs consisting of 64 wind turbines(WTs)is used to validate the proposed DARPC strategy.