A new configuration realizing water quality monitoring device using ISFET involving low power CMOS Integrated “Ion Sensitive Field Effect transistor (ISFET) – Operational Amplifier is presented. The study’s main fo...A new configuration realizing water quality monitoring device using ISFET involving low power CMOS Integrated “Ion Sensitive Field Effect transistor (ISFET) – Operational Amplifier is presented. The study’s main focus is on simulation of power and performance analysis of ISFET device, which is used for water quality monitoring. This approach can improve calibration of device to a fairly wide range without the use of a high speed digital processor. The conventional device has a drawback of slow slew rate but in this novel design, the device has a better slew rate. A new slew rate enhancement (SRE) incorporated into a ISFET, which does not affect the small signal frequency response. The functionality of the circuit is tested using Tanner simulator version 15 for a 70nm CMOS process model also the transfer function realization is done on MATLAB R2011a version, the Very high speed integrated circuit Hardware description language(VHDL) code for the same scheme is simulated on Xilinx ISE 10.1 and various simulation results are obtained. Simulation results are included to demonstrate the results.展开更多
The spice model for photo catalytic sensor (PCS) proposed by Whig and Ahmad overcomes several drawbacks like complex designing, non-linearity, and long computation time generally found in the flow injection analysis...The spice model for photo catalytic sensor (PCS) proposed by Whig and Ahmad overcomes several drawbacks like complex designing, non-linearity, and long computation time generally found in the flow injection analysis (FIA) technique by Yoon-Chang Kim et al. for the determination of chemical oxygen demand (COD). The FIA technique involves the complete analysis including sampling and washing. The flow injection analysis is an analytical method for the measurement of the chemical oxygen demand by using the photochemical column. This method uses a bulky setup and takes 10 minutes to 15 minutes to get the output result which is a tedious and time consuming job. If the conventional method is continuously used for a long time then it is stable only for 15 days. The purpose of this paper is to propose a new floating gate photo catalytic sensor (FGPCS) approach which has low power consumption and more user-friendly, and it is fast in operation by the modeling and optimization of sensor used for water quality monitoring. The proposed model operates under sub-threshold conditions which are appreciated in large integrated system design. The results of simulation are found to be fairly in agreement with the theoretical predictions. The results exhibit near linear variations of parameters of interest with appreciably reduced response time.展开更多
文摘A new configuration realizing water quality monitoring device using ISFET involving low power CMOS Integrated “Ion Sensitive Field Effect transistor (ISFET) – Operational Amplifier is presented. The study’s main focus is on simulation of power and performance analysis of ISFET device, which is used for water quality monitoring. This approach can improve calibration of device to a fairly wide range without the use of a high speed digital processor. The conventional device has a drawback of slow slew rate but in this novel design, the device has a better slew rate. A new slew rate enhancement (SRE) incorporated into a ISFET, which does not affect the small signal frequency response. The functionality of the circuit is tested using Tanner simulator version 15 for a 70nm CMOS process model also the transfer function realization is done on MATLAB R2011a version, the Very high speed integrated circuit Hardware description language(VHDL) code for the same scheme is simulated on Xilinx ISE 10.1 and various simulation results are obtained. Simulation results are included to demonstrate the results.
文摘The spice model for photo catalytic sensor (PCS) proposed by Whig and Ahmad overcomes several drawbacks like complex designing, non-linearity, and long computation time generally found in the flow injection analysis (FIA) technique by Yoon-Chang Kim et al. for the determination of chemical oxygen demand (COD). The FIA technique involves the complete analysis including sampling and washing. The flow injection analysis is an analytical method for the measurement of the chemical oxygen demand by using the photochemical column. This method uses a bulky setup and takes 10 minutes to 15 minutes to get the output result which is a tedious and time consuming job. If the conventional method is continuously used for a long time then it is stable only for 15 days. The purpose of this paper is to propose a new floating gate photo catalytic sensor (FGPCS) approach which has low power consumption and more user-friendly, and it is fast in operation by the modeling and optimization of sensor used for water quality monitoring. The proposed model operates under sub-threshold conditions which are appreciated in large integrated system design. The results of simulation are found to be fairly in agreement with the theoretical predictions. The results exhibit near linear variations of parameters of interest with appreciably reduced response time.