This study examined levels of polycyclic aromatic hydrocarbons (PAHs) in estuarine sediments in Licun (Qingdao, China) by gas chromatography under optimized conditions for sample pretreatment via ultrasonic extraction...This study examined levels of polycyclic aromatic hydrocarbons (PAHs) in estuarine sediments in Licun (Qingdao, China) by gas chromatography under optimized conditions for sample pretreatment via ultrasonic extraction, column chromatography, and thin layer chromatography. Methanol and dichloromethane (DCM)/methanol (2:1, v/v) were used in ultrasonic extraction, and DCM was used as eluate for column chromatography. The developing system consisted of n-hexane and DCM at a ratio of 9:1 (v/v), with DCM as the extraction solvent for PAHs-containing silica gel scraped off the plate. When the spiking level is 100 ng, total recoveries of spiked matrices for four target PAHs (phenanthrene, anthracene, pyrene and chrysene) were 83.7%, 76.4%, 85.8%, and 88.7%, respectively, with relative standard deviation (RSD) between 5.0% and 6.5% (n = 4). When the spiking level is 1000 ng, associated total recoveries were 78.6%, 72.7%, 82.7% and 85.3%, respectively, with RSD between 4.4% and 5.3% (n = 4). The opti-mized method was advantageous for determination of PAHs in complex matrix due to its effective sample purification.展开更多
The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were pu...The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were purified with a miniaturized silica gel chromatographic column and analyzed with high performance liquid chromatography (HPLC) with a fluorescence detector. Ultrasonication with methanol-dichloromethane (2:1, v/v) mixture gave higher extraction efficiency than that with dichloromethane. Among the three elution solvents used in clean-up step, dichloromethane-hexane (2:3, v/v) mixture was the most satisfactory. Under the optimized conditions, the recoveries in the range of 54.82% to 94.70% with RSDs of 3.02% to 23.22% for a spiked blank, and in the range of 61.20% to 127.08% with RSDs of 7.61% to 26.93% for a spiked matrix, were obtained for the 15 PAHs studied, while the recoveries for a NIST standard reference SRM 1941b were in the range of 50.79% to 83.78% with RSDs of 5.24% to 21.38%. The detection limits were between 0.75 ng L-1 and 10.99 ng L-1for different PAHs. A sample from the Jiaozhou Bay area was examined to test the established methods.展开更多
基金supported by the National Natural Science Foundation of China (NSFC project 20775074)
文摘This study examined levels of polycyclic aromatic hydrocarbons (PAHs) in estuarine sediments in Licun (Qingdao, China) by gas chromatography under optimized conditions for sample pretreatment via ultrasonic extraction, column chromatography, and thin layer chromatography. Methanol and dichloromethane (DCM)/methanol (2:1, v/v) were used in ultrasonic extraction, and DCM was used as eluate for column chromatography. The developing system consisted of n-hexane and DCM at a ratio of 9:1 (v/v), with DCM as the extraction solvent for PAHs-containing silica gel scraped off the plate. When the spiking level is 100 ng, total recoveries of spiked matrices for four target PAHs (phenanthrene, anthracene, pyrene and chrysene) were 83.7%, 76.4%, 85.8%, and 88.7%, respectively, with relative standard deviation (RSD) between 5.0% and 6.5% (n = 4). When the spiking level is 1000 ng, associated total recoveries were 78.6%, 72.7%, 82.7% and 85.3%, respectively, with RSD between 4.4% and 5.3% (n = 4). The opti-mized method was advantageous for determination of PAHs in complex matrix due to its effective sample purification.
基金supported by the National Natural Science Foundation of China (Grant No.20775074)
文摘The procedures of ultrasonic extraction and clean-up were optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. Samples were ultrasonically extracted, and the extracts were purified with a miniaturized silica gel chromatographic column and analyzed with high performance liquid chromatography (HPLC) with a fluorescence detector. Ultrasonication with methanol-dichloromethane (2:1, v/v) mixture gave higher extraction efficiency than that with dichloromethane. Among the three elution solvents used in clean-up step, dichloromethane-hexane (2:3, v/v) mixture was the most satisfactory. Under the optimized conditions, the recoveries in the range of 54.82% to 94.70% with RSDs of 3.02% to 23.22% for a spiked blank, and in the range of 61.20% to 127.08% with RSDs of 7.61% to 26.93% for a spiked matrix, were obtained for the 15 PAHs studied, while the recoveries for a NIST standard reference SRM 1941b were in the range of 50.79% to 83.78% with RSDs of 5.24% to 21.38%. The detection limits were between 0.75 ng L-1 and 10.99 ng L-1for different PAHs. A sample from the Jiaozhou Bay area was examined to test the established methods.