Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding an...Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities.展开更多
AIM:To investigate the potential benef it of Fujinon in-telligent chromo endoscopy(FICE)-assisted small bowel capsule endoscopy(SBCE)for detection and character-ization of small bowel lesions in patients with obscure ...AIM:To investigate the potential benef it of Fujinon in-telligent chromo endoscopy(FICE)-assisted small bowel capsule endoscopy(SBCE)for detection and character-ization of small bowel lesions in patients with obscure gastroenterology bleeding(OGIB).METHODS:The SBCE examinations(Pillcam SB2,Giv-en Imaging Ltd)were retrospectively analyzed by two GI fellows(observers)with and without FICE enhance-ment.Randomization was such that a fellow did not assess the same examination with and without FICE enhancement.The senior consultant described f indings as P0,P1 and P2 lesions(non-pathological,intermedi-ate bleed potential,high bleed potential),which were considered as reference f indings.Main outcome mea-surements:Inter-observer correlation was calculated using kappa statistics.Sensitivity and specif icity for P2 lesions was calculated for FICE and white light SBCE.RESULTS:In 60 patients,the intra-class kappa cor-relations between the observers and reference f indings were 0.88 and 0.92(P2),0.61 and 0.79(P1),for SBCE using FICE and white light,respectively.Overall 157 le-sions were diagnosed using FICE as compared to 114 with white light SBCE(P = 0.15).For P2 lesions,the sensitivity was 94% vs 97% and specif icity was 95% vs 96% for FICE and white light,respectively.Five(P2 le-sions)out of 55 arterio-venous malformations could be better characterized by FICE as compared to white light SBCE.Significantly more P0 lesions were diagnosed when FICE was used as compared to white light(39 vs 8,P < 0.001).CONCLUSION:FICE was not better than white light for diagnosing and characterizing signif icant lesions on SBCE for OGIB.FICE detected signif icantly more non-pathological lesions.Nevertheless,some vascular le-sions could be more accurately characterized with FICE as compared to white light SBCE.展开更多
文摘Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities.
文摘AIM:To investigate the potential benef it of Fujinon in-telligent chromo endoscopy(FICE)-assisted small bowel capsule endoscopy(SBCE)for detection and character-ization of small bowel lesions in patients with obscure gastroenterology bleeding(OGIB).METHODS:The SBCE examinations(Pillcam SB2,Giv-en Imaging Ltd)were retrospectively analyzed by two GI fellows(observers)with and without FICE enhance-ment.Randomization was such that a fellow did not assess the same examination with and without FICE enhancement.The senior consultant described f indings as P0,P1 and P2 lesions(non-pathological,intermedi-ate bleed potential,high bleed potential),which were considered as reference f indings.Main outcome mea-surements:Inter-observer correlation was calculated using kappa statistics.Sensitivity and specif icity for P2 lesions was calculated for FICE and white light SBCE.RESULTS:In 60 patients,the intra-class kappa cor-relations between the observers and reference f indings were 0.88 and 0.92(P2),0.61 and 0.79(P1),for SBCE using FICE and white light,respectively.Overall 157 le-sions were diagnosed using FICE as compared to 114 with white light SBCE(P = 0.15).For P2 lesions,the sensitivity was 94% vs 97% and specif icity was 95% vs 96% for FICE and white light,respectively.Five(P2 le-sions)out of 55 arterio-venous malformations could be better characterized by FICE as compared to white light SBCE.Significantly more P0 lesions were diagnosed when FICE was used as compared to white light(39 vs 8,P < 0.001).CONCLUSION:FICE was not better than white light for diagnosing and characterizing signif icant lesions on SBCE for OGIB.FICE detected signif icantly more non-pathological lesions.Nevertheless,some vascular le-sions could be more accurately characterized with FICE as compared to white light SBCE.