A simulation framework is proposed to evaluate the voltage stability of power systems incorporating wind power intermittency.Firstly,the power output modelings of three types of wind turbines are discussed.Secondly,...A simulation framework is proposed to evaluate the voltage stability of power systems incorporating wind power intermittency.Firstly,the power output modelings of three types of wind turbines are discussed.Secondly,the Jensen model is employed to simulate the wind farm with the wake effect.The Monte Carlo based technique is used to conduct the voltage stability evaluation incorporating the randomness of the wind speed based on the Weibull probability distribution.Thirdly,the relative sensitivity index(RSI)is calculated to identify weak buses during analysis.Finally,case studies with different simulation scenarios are carried out.Some statistical results involving weakness probability,expected value and variance of RSI as well as preliminary conclusions are drawn based on numerical simulation results.展开更多
The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/...The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/converter model, the comprehensive numerical simulations with multiple wind farms of DFIG type involved are carried out to reveal the impact of wind farm on dynamic behavior of existing interconnected power system. Different load models involving nonlinear load model and induction motor model are considered during simulations. Finally, some preliminary conclusions are summarized and discussed.展开更多
This paper presents an adaptive Under Frequency Load Shedding scheme based on Wide Area Measurement System. Due to the lack of enough adaptability to the operation state of the system, the traditional successive appro...This paper presents an adaptive Under Frequency Load Shedding scheme based on Wide Area Measurement System. Due to the lack of enough adaptability to the operation state of the system, the traditional successive approximation under frequency load shedding method will cause excessive cut or undercut problems inevitably. This method consists first in a comprehensive weight index including load characteristics and inertias of generators. Then active-power deficit calculation based on the Low-order Frequency Response Model, concerning the effect of voltage was put forward. Finally, a dynamic correction of the load shedding amount was proposed to modify the scheme. This approach was applied to IEEE-39 system and the simulation results indicated that the proposed method was effective in reducing the load shedding amount as well as the frequency recovery time.展开更多
基金This work is supported by National Natural Science Foundation of China (No. 50977051 ) and Research Project of Science and Technology from Shenzhen Development and Innovation Committee (No. ZDSY20120619141142918).
文摘A simulation framework is proposed to evaluate the voltage stability of power systems incorporating wind power intermittency.Firstly,the power output modelings of three types of wind turbines are discussed.Secondly,the Jensen model is employed to simulate the wind farm with the wake effect.The Monte Carlo based technique is used to conduct the voltage stability evaluation incorporating the randomness of the wind speed based on the Weibull probability distribution.Thirdly,the relative sensitivity index(RSI)is calculated to identify weak buses during analysis.Finally,case studies with different simulation scenarios are carried out.Some statistical results involving weakness probability,expected value and variance of RSI as well as preliminary conclusions are drawn based on numerical simulation results.
文摘The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/converter model, the comprehensive numerical simulations with multiple wind farms of DFIG type involved are carried out to reveal the impact of wind farm on dynamic behavior of existing interconnected power system. Different load models involving nonlinear load model and induction motor model are considered during simulations. Finally, some preliminary conclusions are summarized and discussed.
文摘This paper presents an adaptive Under Frequency Load Shedding scheme based on Wide Area Measurement System. Due to the lack of enough adaptability to the operation state of the system, the traditional successive approximation under frequency load shedding method will cause excessive cut or undercut problems inevitably. This method consists first in a comprehensive weight index including load characteristics and inertias of generators. Then active-power deficit calculation based on the Low-order Frequency Response Model, concerning the effect of voltage was put forward. Finally, a dynamic correction of the load shedding amount was proposed to modify the scheme. This approach was applied to IEEE-39 system and the simulation results indicated that the proposed method was effective in reducing the load shedding amount as well as the frequency recovery time.