A study of liquid argon detector’s n/discrimination capability with PMT or SiPM readout
1
作者 Y.D.Chen Y.Lei +6 位作者 L.Wang m.y.guan T.A.Wang C.Guo J.C.Liu C.G.Yang X.H.Liang 《Radiation Detection Technology and Methods》 CSCD 2024年第2期1246-1253,共8页
Background Liquid Argon(LAr)is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection.Argon provides excellent pulse shape discrimination(PS... Background Liquid Argon(LAr)is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection.Argon provides excellent pulse shape discrimination(PSD)capability,which could separate the electron recoil backgrounds from the expected nuclear recoil signals.As the next-generation photosensors,silicon photon multiplier(SiPM)is expected to replace traditional photon multiplier tubes.Purpose The purpose of this paper is to compare the PSD capability of a LAr detector between using SiPMs as photosensors and using PMTs as photosensors.Methods The PSD capability of a LAr detector is determined through the prompt fraction method,which relies on the analysis of output pulses.These pulses are generated using Monte Carlo simulation,incorporating real single photoelectron pulses obtained from a PMT or a SiPM.Results Three kinds of SiPMs and one kind of PMT have been used to compare the PSD capability of a LAr detector.The use of J-60035 SiPM results in a better PSD capability compared to the use of PMT as a photosensor,while using the other two kinds of SiPM deteriorates the PSD capability.Conclusion SiPM is a promising photosensor candidate for a LAr detector.The better energy resolution could help to improve its PSD capability,while the higher probabilities of cross-talk and after-pulse degrade its PSD capability.Notably,after-pulse has a more significant impact compared to cross-talk because after-pulse influences the energy distribution within the time window,while cross-talk primarily affects the energy resolution of the detector. 展开更多
关键词 Liquid argon SIPM PMT F90 PSD
原文传递
The development of ^(222)Rn detectors for JUNO prototype
2
作者 Y.P.Zhang J.C.Liu +5 位作者 C.Guo Y.B.Huang C.Xu m.y.guan C.G.Yang P.Zhang 《Radiation Detection Technology and Methods》 2018年第1期32-37,共6页
Background JUNO(The Jiangmen Underground Neutrino Observatory)is a multipurpose neutrino experiment,and it has very strict requirements for the detector.According to the MC simulation for JUNO experiment requirements,... Background JUNO(The Jiangmen Underground Neutrino Observatory)is a multipurpose neutrino experiment,and it has very strict requirements for the detector.According to the MC simulation for JUNO experiment requirements,the Rn concentration in the water of the veto detector should be less than 0.2Bq/m^(3).In order to measure such low Rn concentration,two kinds of high-sensitivity Rn measurement systems have been developed.Method Based on the water system of JUNO prototype,two kinds of high-sensitivity Rn detectors have been developed,namely the Si-PIN Rn detector and the LS Rn detector.The Si-PIN Rn detector uses a Si-PIN photodiode to detect theαfrom ^(214)Po decay and the LS Rn detector detects the coincident signals ofβfrom ^(214)Bi decay andβfrom ^(214)Po decay.Result The background measurement of Si-PIN Rn detector and LS Rn detector is performed to estimate the sensitivity.The sensitivity of Si-PIN Rn detector is around 9.0mBq/m^(3) and the sensitivity of LS Rn detector is around 64.0Bq/m^(3).Conclusion Both of the Si-PIN Rn detector and the LS Rn detector are working well with the JUNO prototype at present,and both of them can be developed as an online Rn concentration monitoring device for JUNO veto detector. 展开更多
关键词 RADON Si-PIN Liquid scintillator
原文传递