During the year of 2014, the work of cryogenic group was mainly focused on operation of refrigerator system,test of TCM1, design and machining of HCM6. At the end of 2014 refrigerator system has achieved closed-loopop...During the year of 2014, the work of cryogenic group was mainly focused on operation of refrigerator system,test of TCM1, design and machining of HCM6. At the end of 2014 refrigerator system has achieved closed-loopoperation and recycle of helium gas, which did great contribution to superconducting cavity and superconductingmagnet test. Since the refrigerator was put into use(Fig. 1), it has operated continuously and reliably for more than5 110 h, reached helium lique ed capacity 270 L/h at 850 W.展开更多
The superconducting accelerating segment in injectorⅡof Accelerator Driven Sub-critical System(ADS) uses superconductingcavities whose frequency are 162.5 MHz. The vertical performance of superconducting cavity devic...The superconducting accelerating segment in injectorⅡof Accelerator Driven Sub-critical System(ADS) uses superconductingcavities whose frequency are 162.5 MHz. The vertical performance of superconducting cavity devicesmust be tested at liquid helium temperature(2, 4.2 K) before being assembled in cryostat. To meet the runninggoal of the 0 25 MeV linac system, it is necessary to build a set of cryogenic testing system for superconductingcavity, which is used to test the performance of the superconducting cavity and whether cavity meet the designgoal.展开更多
文摘During the year of 2014, the work of cryogenic group was mainly focused on operation of refrigerator system,test of TCM1, design and machining of HCM6. At the end of 2014 refrigerator system has achieved closed-loopoperation and recycle of helium gas, which did great contribution to superconducting cavity and superconductingmagnet test. Since the refrigerator was put into use(Fig. 1), it has operated continuously and reliably for more than5 110 h, reached helium lique ed capacity 270 L/h at 850 W.
文摘The superconducting accelerating segment in injectorⅡof Accelerator Driven Sub-critical System(ADS) uses superconductingcavities whose frequency are 162.5 MHz. The vertical performance of superconducting cavity devicesmust be tested at liquid helium temperature(2, 4.2 K) before being assembled in cryostat. To meet the runninggoal of the 0 25 MeV linac system, it is necessary to build a set of cryogenic testing system for superconductingcavity, which is used to test the performance of the superconducting cavity and whether cavity meet the designgoal.