Objective:This randomized study aimed to compare the clinical efficacy between the novel dual tracer composed of indocyanine green(ICG)and blue dye(BD)and the conventional dual tracer composed of radioisotope and BD f...Objective:This randomized study aimed to compare the clinical efficacy between the novel dual tracer composed of indocyanine green(ICG)and blue dye(BD)and the conventional dual tracer composed of radioisotope and BD for sentinel lymph node(SLN)mapping in patients with breast cancer.Methods:This study enrolled 471 clinically lymph node-negative patients with primary breast cancer.All patients underwent mastectomy,and those undergoing sentinel lymph node biopsy(SLNB)were randomized to receive blue dye plus radioisotope(RB group)or BD plus ICG(IB group).The detection performances on SLN identification rate,positive SLN counts,detection sensitivity,and false-negative rate were compared between the two groups.Results:In the IB group,97%(194/200)of the patients who underwent the ICG and BD dual tracer injection showed fluorescentpositive lymphatic vessels within 2–5 min.The identification rate of SLNs was comparable between the IB group(99.0%,198/200)and the RB group(99.6%,270/271)(P=0.79).No significant differences were observed in the identification rate of metastatic SLNs(22.5%vs.22.9%,P>0.05,RB group vs.IB group,the same below),positive SLN counts(3.72±2.28 vs.3.91±2.13,P>0.05),positive metastatic SLN counts(0.38±0.84 vs.0.34±0.78,P>0.05),SLNB detection sensitivity(94.4%vs.92.5%,P>0.05),or false-negative rate(5.6%vs.7.5%,P>0.05)between the two groups.Conclusions:ICG can be used as a promising alternative tracer for radioisotope in SLN mapping,and when it is combined with BD in lymphangiography,it offers comparable detection sensitivity compared to the conventional lymphatic mapping strategies that are widely used in clinical practice.展开更多
Radiator thermal performance test equipment plays a key role in the processing of developing a new type of heat radiator and its application products.The precise of temperature controlling,temperature measuring andflo...Radiator thermal performance test equipment plays a key role in the processing of developing a new type of heat radiator and its application products.The precise of temperature controlling,temperature measuring andflow measuring are the vital factors for a radiator thermal performance test equipment.Based on the above back-ground,this paper improves the measurement and control system of radiator thermal performance test equip-ment,which improves the accuracy of the radiator thermal performance test equipment.This paper also optimizes the software and hardware system simultaneously so as to improve the precision of the auto-test system of test equipment.Theflow rate ranges from 175 kg/h to 178 kg/h under different conditions.The average is 176.5 kg/h and the deviation rates are from 1.62%to 1.97%.The heat produced under various conditions is different.The maximum is 4.3 kW and the minimum is 4.2 kW for condition 1,the maximum is 3.3 kW and the minimum is 3.2 kW for condition 2 and the maximum is 1.95 kW and the minimum is 1.89 kW for condition 3.However,the deviation rate is about 2.9%,which shows that the device has high stability and high precision.This paper studies a new electronic heat cost allocate meter test method by radiator thermal performance test equipment at the same time.This paper tests temperature changes through four measures points and gets a result appeared as a heat backup which should be avoided when using in the test of electronic heat cost allocate meter.Some experiences and references could be gained for further research in the heating system from this test and research.展开更多
基金supported by grants from the Clinical Research Founding of Southwest Hospital (Grant No. SWH2016BZGFKJ-30), Technological Innovation for Intelligent Medicine of Southwest Hospital (Grant No. SWH2016ZDCX4403) Talents Training Program of Third Military Medical University (Grant No. 2017MPRC18)
文摘Objective:This randomized study aimed to compare the clinical efficacy between the novel dual tracer composed of indocyanine green(ICG)and blue dye(BD)and the conventional dual tracer composed of radioisotope and BD for sentinel lymph node(SLN)mapping in patients with breast cancer.Methods:This study enrolled 471 clinically lymph node-negative patients with primary breast cancer.All patients underwent mastectomy,and those undergoing sentinel lymph node biopsy(SLNB)were randomized to receive blue dye plus radioisotope(RB group)or BD plus ICG(IB group).The detection performances on SLN identification rate,positive SLN counts,detection sensitivity,and false-negative rate were compared between the two groups.Results:In the IB group,97%(194/200)of the patients who underwent the ICG and BD dual tracer injection showed fluorescentpositive lymphatic vessels within 2–5 min.The identification rate of SLNs was comparable between the IB group(99.0%,198/200)and the RB group(99.6%,270/271)(P=0.79).No significant differences were observed in the identification rate of metastatic SLNs(22.5%vs.22.9%,P>0.05,RB group vs.IB group,the same below),positive SLN counts(3.72±2.28 vs.3.91±2.13,P>0.05),positive metastatic SLN counts(0.38±0.84 vs.0.34±0.78,P>0.05),SLNB detection sensitivity(94.4%vs.92.5%,P>0.05),or false-negative rate(5.6%vs.7.5%,P>0.05)between the two groups.Conclusions:ICG can be used as a promising alternative tracer for radioisotope in SLN mapping,and when it is combined with BD in lymphangiography,it offers comparable detection sensitivity compared to the conventional lymphatic mapping strategies that are widely used in clinical practice.
基金supported by the Tianjin Science and Technology Project(Project No.19JCTPJC44300)The Science&Technology Development Fund of Tianjin Education Commission for Higher Education(Project No.2018KJ261)Science and Technology Program Project of Jin Nan District Tianjin(Project Nos.201805015&20190111).
文摘Radiator thermal performance test equipment plays a key role in the processing of developing a new type of heat radiator and its application products.The precise of temperature controlling,temperature measuring andflow measuring are the vital factors for a radiator thermal performance test equipment.Based on the above back-ground,this paper improves the measurement and control system of radiator thermal performance test equip-ment,which improves the accuracy of the radiator thermal performance test equipment.This paper also optimizes the software and hardware system simultaneously so as to improve the precision of the auto-test system of test equipment.Theflow rate ranges from 175 kg/h to 178 kg/h under different conditions.The average is 176.5 kg/h and the deviation rates are from 1.62%to 1.97%.The heat produced under various conditions is different.The maximum is 4.3 kW and the minimum is 4.2 kW for condition 1,the maximum is 3.3 kW and the minimum is 3.2 kW for condition 2 and the maximum is 1.95 kW and the minimum is 1.89 kW for condition 3.However,the deviation rate is about 2.9%,which shows that the device has high stability and high precision.This paper studies a new electronic heat cost allocate meter test method by radiator thermal performance test equipment at the same time.This paper tests temperature changes through four measures points and gets a result appeared as a heat backup which should be avoided when using in the test of electronic heat cost allocate meter.Some experiences and references could be gained for further research in the heating system from this test and research.