This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interf...This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.展开更多
This paper presents equipment for early detection of failures in the insulation of power transformers, checking existing partial discharges inside. The equipment involves hardware, control and signal acquisition softw...This paper presents equipment for early detection of failures in the insulation of power transformers, checking existing partial discharges inside. The equipment involves hardware, control and signal acquisition software, and signal analysis software. This equipment has a set of algorithms that were made with intelligent extraction techniques and interpretation of data. The degradation diagnosis of the equipment insulation is based on digital signal processing algorithms for extraction of features and also in artificial intelligence algorithms that allies a mining involving all the data linked to the equipment throughout its operating life can make an assessment of the operating conditions of the equipment and suggest interventions and provide an estimated time so that they have to be made.展开更多
文摘This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.
文摘This paper presents equipment for early detection of failures in the insulation of power transformers, checking existing partial discharges inside. The equipment involves hardware, control and signal acquisition software, and signal analysis software. This equipment has a set of algorithms that were made with intelligent extraction techniques and interpretation of data. The degradation diagnosis of the equipment insulation is based on digital signal processing algorithms for extraction of features and also in artificial intelligence algorithms that allies a mining involving all the data linked to the equipment throughout its operating life can make an assessment of the operating conditions of the equipment and suggest interventions and provide an estimated time so that they have to be made.