期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
CM-Droid: Secure Container for Android Password Misuse Vulnerability 被引量:1
1
作者 Wen Zhang keyue li +2 位作者 Tianyang li Shaozhang Niu Zhenguang Gao 《Computers, Materials & Continua》 SCIE EI 2019年第4期181-198,共18页
Android applications are associated with a large amount of sensitive data,therefore application developers use encryption algorithms to provide user data encryption,authentication and data integrity protection.However... Android applications are associated with a large amount of sensitive data,therefore application developers use encryption algorithms to provide user data encryption,authentication and data integrity protection.However,application developers do not have the knowledge of cryptography,thus the cryptographic algorithm may not be used correctly.As a result,security vulnerabilities are generated.Based on the previous studies,this paper summarizes the characteristics of password misuse vulnerability of Android application software,establishes an evaluation model to rate the security level of the risk of password misuse vulnerability and develops a repair strategy for password misuse vulnerability.And on this basis,this paper designs and implements a secure container for Android application software password misuse vulnerability:CM-Droid. 展开更多
关键词 Password misuse evaluation model secure container dynamic repair
在线阅读 下载PDF
Comparative analysis of formulae for umbilical venous catheterization depth based on birth weight 被引量:1
2
作者 Jingjie Luo Xu Zheng +3 位作者 Zixin Yang keyue li Lu Chen Mingyan Hei 《Pediatric Investigation》 CSCD 2024年第4期265-270,共6页
Importance:Umbilical venous catheterization(UVC)is a common procedure for critically ill newborn infants.The insertion depth was estimated before the procedure using various formulae.Objective:To compare the accuracy ... Importance:Umbilical venous catheterization(UVC)is a common procedure for critically ill newborn infants.The insertion depth was estimated before the procedure using various formulae.Objective:To compare the accuracy of five published formulae based on birth weight(BW).Methods:This is a secondary retrospective analysis using data collected in a previous study,in which the actual final insertion depth of UVC was recorded.Predicted insertion depths were calculated by five published formulae based on BW.Then the actual depth and predicted depth were compared.Accurate position was defined as predicted depth being within±10%of actual depth.The accuracy rate calculated as"(accurately positioned UVCs/all UVCs)×100%"and the ratio of difference calculated as"(|predicted depth−actual depth|/actual depth)"were compared among five formulae.Results:Totally 1298 were enrolled,with gestational age 29.8±2.3 weeks and BW 1215±273 g.The accuracy rates were:Tambasco formula(67.2%),Shukla formula(65.0%),JSS formula(64.4%),BW formula(48.9%),and revised Shukla formula(26.9%).Tambasco formula had the highest accuracy rate in newborns with BW≥1000 g.JSS formula had the highest accuracy rate in newborns with BW<1000 g.Interpretation:It is suggested to use the Tambasco formula for estimating the UVC insertion depth for newborns,especially for those with BW≥1000 g,and to apply the JSS formula for newborns with BW<1000 g.There is no universal formula for achieving 100%accurate positioning. 展开更多
关键词 ACCURACY DEPTH INFANT NEWBORN Umbilical vein catheterization
原文传递
上一页 1 下一页 到第