The synchrotron radiation beamline BL17B of the National Facility for Protein Science(NFPS)in Shanghai,situated at the Shanghai Synchrotron Radiation Facility(SSRF),was originally designed for diffraction experiments ...The synchrotron radiation beamline BL17B of the National Facility for Protein Science(NFPS)in Shanghai,situated at the Shanghai Synchrotron Radiation Facility(SSRF),was originally designed for diffraction experiments and accommodates techniques including single-crystal diffraction,powder diffraction,and grazing-incidence wide-angle X-ray scattering(GIWAXS)to enable the characterization of long-range ordered atomic structures.The academic community associated with BL17B engages in research domains encompassing biology,environment,energy,and materials,and a pronounced demand for characterizing short-range ordered structures exists.To address these requirements,BL17B established an advanced X-ray absorption fine structure(XAFS)experimental platform that enabled it to address a wide range of systems,from crystalline to amorphous and from long-range order to short-range order.The XAFS platform allows simultaneous XAFS data acquisition for both the transmission and fluorescence modes within an energy range of 5-23 keV,encompassing the K-edges of titanium to ruthenium and the L3-edges of cesium to bismuth.The platform exemplifies high levels of automation achieved through automated sample assessment and data collection based on large-capacity sample wheels that facilitate remote sample loading.When integrated with a highly integrated control system that simplifies experimental preparation and data collection,the XAFS platform significantly bolsters experimental efficiency and enhances user experience.Notably,the platform boasts an impressively low extended X-ray absorption fine structure(EXAFS)detection limit of 0.04 wt%for dilute copper phthalocyanine(CuPc)samples and an even more remarkable X-ray absorption near edge structure(XANES)detection threshold of 0.01 wt%.These results demonstrate the methodology?s reliability in low-concentration sample analysis,confirming its capability to generate high-quality XAFS data.展开更多
基金supported by the Chinese Academy of Science(CAS)Key Technology Talent Program(No.2021000022)。
文摘The synchrotron radiation beamline BL17B of the National Facility for Protein Science(NFPS)in Shanghai,situated at the Shanghai Synchrotron Radiation Facility(SSRF),was originally designed for diffraction experiments and accommodates techniques including single-crystal diffraction,powder diffraction,and grazing-incidence wide-angle X-ray scattering(GIWAXS)to enable the characterization of long-range ordered atomic structures.The academic community associated with BL17B engages in research domains encompassing biology,environment,energy,and materials,and a pronounced demand for characterizing short-range ordered structures exists.To address these requirements,BL17B established an advanced X-ray absorption fine structure(XAFS)experimental platform that enabled it to address a wide range of systems,from crystalline to amorphous and from long-range order to short-range order.The XAFS platform allows simultaneous XAFS data acquisition for both the transmission and fluorescence modes within an energy range of 5-23 keV,encompassing the K-edges of titanium to ruthenium and the L3-edges of cesium to bismuth.The platform exemplifies high levels of automation achieved through automated sample assessment and data collection based on large-capacity sample wheels that facilitate remote sample loading.When integrated with a highly integrated control system that simplifies experimental preparation and data collection,the XAFS platform significantly bolsters experimental efficiency and enhances user experience.Notably,the platform boasts an impressively low extended X-ray absorption fine structure(EXAFS)detection limit of 0.04 wt%for dilute copper phthalocyanine(CuPc)samples and an even more remarkable X-ray absorption near edge structure(XANES)detection threshold of 0.01 wt%.These results demonstrate the methodology?s reliability in low-concentration sample analysis,confirming its capability to generate high-quality XAFS data.