Impact of Duty Cycling HVAC Systems on Thermal Comfort,Energy Consumption,and Operational Costs
1
作者 Alya Penta Agharid indra permana +2 位作者 Linlan Chang Yi-Han Luo Fujen Wang 《Energy Engineering》 2025年第9期3839-3866,共28页
Air conditioning(AC)is essential for maintaining indoor comfort during Taiwan region’s hot and humid summers but significantly contributes to increased energy consumption.This study evaluates the effects of AC dutycy... Air conditioning(AC)is essential for maintaining indoor comfort during Taiwan region’s hot and humid summers but significantly contributes to increased energy consumption.This study evaluates the effects of AC dutycycling strategies on energy performance,thermal comfort,and operational costs in office environments.Duty-cycling was implemented using a building energy management system(BEMS),which remotely controlled the ON/OFF cycles of AC units.Five duty-cycling modes were tested,with some modes incorporating air circulation during OFF periods.Field measurements of energy consumption,temperature,humidity,and air velocity were conducted and integrated with thermal comfort analysis tools to calculate predictedmean vote(PMV)and percentage of dissatisfied(PPD)values.The objective was to achieve energy savings while maintaining acceptable thermal comfort levels.Results show that Mode A achieved the highest energy savings,reducing monthly consumption by 40.79%;however,it slightly exceeded the PMV threshold(+0.5)and recorded a PPD greater than 10%,indicating reduced occupant comfort.In contrast,Mode C provided a better balance,achieving a 27.61%reduction in energy consumption while maintaining a PMV of+0.28 and a PPD of 7.49%,both within acceptable comfort limits.Despite the energy-saving benefits,not all dutycycling modes ensured satisfactory thermal comfort.Additionally,the cost analysis revealed thatMode A achieved the lowest monthly electricity cost(NTD 8476.18/USD 263.38),whileMode C incurred a higher cost(NTD 10,363.00/USD 322.01),highlighting the trade-off between energy savings,comfort,and economic impact. 展开更多
关键词 Air conditioning duty cycle ENERGY-SAVING thermal comfort field measurement
在线阅读 下载PDF
Energy-Efficient Air Conditioning System with Combined a Ceiling Fan for Thermal Comfort in an Office
2
作者 Linlan Chang Win-Jet Luo +3 位作者 indra permana Bowo Yuli Prasetyo Alya Penta Agharid Fujen Wang 《Energy Engineering》 2025年第5期1771-1787,共17页
Heating,Ventilation,andAir Conditioning(HVAC)systems are critical formaintaining thermal comfort in office environments which also crucial for occupant well-being and productivity.This study investigates the impact of... Heating,Ventilation,andAir Conditioning(HVAC)systems are critical formaintaining thermal comfort in office environments which also crucial for occupant well-being and productivity.This study investigates the impact of integrating ceiling fans with higher air conditioning setpoints on thermal comfort and energy efficiency in office environments.Field measurements and questionnaire surveys were conducted to evaluate thermal comfort and energysaving potential under varying conditions.Results show that increasing the AC setpoint from 25○C to 27○C,combined with ceiling fan operation,reduced power consumption by 10%,achieving significant energy savings.Survey data confirmed that 85%of participants reported consistent thermal sensations across all conditions,with ceiling fans effectively compensating for higher setpoints through enhanced air circulation.CFDsimulations revealed that mediumspeed ceiling fan operation produced the most uniformairflowdistribution,with an average air velocity of 0.45 m/s,and minimized temperature variations,ensuring balanced thermal conditions.Temperature analysis showed a reduction in hotspots and cold zones,maintaining an average temperature deviation of less than±0.5○C.Predicted Mean Vote(PMV)evaluations at a 27○C setpoint indicated improved thermal comfort,with average PMV values around−0.3,corresponding to a“neutral”thermal sensation.These findings demonstrate the effectiveness of integrating ceiling fans with HVAC systems in achieving energy efficiency and occupant comfort,offering a sustainable approach to reducing AC energy consumption in office environments. 展开更多
关键词 Thermal comfort ceiling fan field measurement questionnaire survey numerical simulation
在线阅读 下载PDF
Energy-Efficient and Cost-Effective Approaches through Energy Modeling for Hotel Building 被引量:1
3
作者 Alya Penta Agharid indra permana +2 位作者 Nitesh Singh Fujen Wang Susan Gustiyana 《Energy Engineering》 EI 2024年第12期3549-3571,共23页
Hotel buildings are currently among the largest energy consumers in the world.Heating,ventilation,and air conditioning are the most energy-intensive building systems,accounting for more than half of total energy consu... Hotel buildings are currently among the largest energy consumers in the world.Heating,ventilation,and air conditioning are the most energy-intensive building systems,accounting for more than half of total energy consumption.An energy audit is used to predict the weak points of a building’s energy use system.Various factors influence building energy consumption,which can be modified to achieve more energy-efficient strategies.In this study,an existing hotel building in Central Taiwan is evaluated by simulating several scenarios using energy modeling over a year.Energy modeling is conducted by using Autodesk Revit 2025.It was discovered from the results that arranging the lighting schedule based on the ASHRAE Standard 90.1 could save up to 8.22%of energy consumption.And then the results also revealed that changing the glazing of the building into double-layer lowemissivity glass could reduce energy consumption by 14.58%.While the energy consumption of the building could also be decreased to 7.20%by changing the building orientation to the north.Meanwhile,moving the building location to Northern Taiwan could also minimize the energy consumption of the building by 3.23%.The results revealed that the double layer offers better thermal insulation,and low-emissivity glass can lower energy consumption,electricity costs,and CO_(2)emissions by up to 15.27%annually.While adjusting orientation and location can enhance energy performance,this approach is impractical for existing buildings,but this could be considered for designing new buildings.The results showed the relevancy of energy performance to CO_(2)emission production and electricity expenses. 展开更多
关键词 ENERGY-EFFICIENT energy modeling field measurement energy saving hotel building
在线阅读 下载PDF
Energy-Efficient Approaches for a Machine Tool Building in a University through Field Measurement and Energy Modelling
4
作者 Kusnandar Win-Jet Luo +2 位作者 indra permana Fu-Jen Wang Gantulga Bayarkhuu 《Energy Engineering》 EI 2023年第6期1387-1399,共13页
The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negativ... The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negative impacts of excessive energy use on the environment,it is essential to employ an energy-efficient HVAC system.This study conducted the machine tools building in a university.The field measurement was carried out,and the data were used to conduct energymodelling with EnergyPlus(EP)in order to discover some improvements in energy-efficient design.The validation between fieldmeasurement and energymodelling was performed,and the error rate was less than 10%.The following strategies were proposed in this study based on several energy-efficient approaches,including room temperature settings,chilled water supply temperature settings,chiller coefficient of performance(COP),shading,and building location.Energy-efficient approaches have been evaluated and could reduce energy consumption annually.The results reveal that the proposed energy-efficient approaches of room temperature settings(3.8%),chilled water supply temperature settings(2.1%),chiller COP(5.9%),using shading(9.1%),and building location(3.0%),respectively,could reduce energy consumption.The analysis discovered that using a well-performing HVAC system and building shading were effective in lowering the amount of energy used,and the energy modelling method could be an effective and satisfactory tool in determining potential energy savings. 展开更多
关键词 ENERGY-EFFICIENT energy modelling field measurement BEMS machine tools building