期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Double-antibody-based nano-biosensing systemfor the onsite monitoring of SARS-CoV-2 variants
1
作者 heba a.hussein Ahmed Kandeil +1 位作者 Mokhtar Gomaa Rabeay Y.A.Hassan 《Microsystems & Nanoengineering》 SCIE CSCD 2023年第4期247-262,共16页
The fast and reliable diagnosis of COVID-19 is the foremost priority for promoting public health interventions.Therefore, double-antibody-based immunobiosensor chips were designed, constructed, and exploited for clini... The fast and reliable diagnosis of COVID-19 is the foremost priority for promoting public health interventions.Therefore, double-antibody-based immunobiosensor chips were designed, constructed, and exploited for clinicaldiagnosis. Gold nanoparticles/tungsten oxide/carbon nanotubes (AuNPs/WO3/CNTs) were used as the active workingsensor surface to support the chemical immobilization of a mixture of SARS-CoV-2 antibodies (anti-RBD-S and anti-RBD-S-anti-Llama monoclonal antibodies). The morphology and chemical functionalization of the fabricateddisposable immunochips was characterized using scanning electron microscopy (SEM), Fourier transform infrared(FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). After full assayoptimization, the immunobiosensor showed a high sensitivity to detect SARS-CoV-2-S protein with limits of detectionand quantification of 1.8 and 5.6 pg/mL, respectively. On the other hand, for the SARS-CoV-2 whole virus particleanalysis, the detection and quantification limits were determined to be 5.7 and 17 pg/mL, respectively. The biosensorshowed a highly selective response toward SARS-CoV-2, even in the presence of influenza, nontargeting humancoronaviruses, and Middle East respiratory syndrome coronavirus (MERS-CoV). The immunochips exhibited distinctresponses toward the variants of concern: B.1>C.36.3>Omicron> Delta> Alpha coronavirus variants. For biosensorvalidation, twenty-nine clinical specimens were analyzed, and the impedimetric responses were positively detected fortwo Delta samples, eighteen Omicron samples, and six B.1-type samples in addition to three negative samples.Eventually, the immunobiosensor was fabricated in the form of ready-to-use chips capable of sensitive detection ofvirus variants, especially variants of concern (VOC) and interest, in a specimen within 15 min. The chips providedinstantaneous detection with the direct application of clinical samples and are considered a point-of-care device thatcould be used in public places and hot spots. 展开更多
关键词 system limits OPTIMIZATION
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部