As the existing coordinated control strategies between grid and unit have limitations in isolated power system, this paper introduces new coordinated control strategies which can improve the stability of isolated syst...As the existing coordinated control strategies between grid and unit have limitations in isolated power system, this paper introduces new coordinated control strategies which can improve the stability of isolated system operation. This paper analyzes the power grid side and unit side influence factors on the isolated power system. The dynamic models which are suitable for islanding operation are applied to simulate and analyze the stability and dynamic characteristics of the isolated power system under the conditions of different load disturbances and governor parameters. With considering the differences of frequency characteristics between the interconnected and isolated power system, the adjusting and optimization methods of under frequency load shedding are proposed to meet the frequency stability requirements simultaneously in the two cases. Not only proper control strategies of the power plant but the settings of their parameters are suggested to improve the operation stability of the isolated power system. To confirm the correctness and effectiveness of the method mentioned above, the isolated system operation test was conducted under the real power system condition, and the results show that the proposed coordinated control strategies can greatly improve stability of the isolated power system.展开更多
In this paper, the model of turbine governor?based on the physical principles is constituted to improve the accuracy of power system dynamic simulation, making the results of simulation consistent with the actual situ...In this paper, the model of turbine governor?based on the physical principles is constituted to improve the accuracy of power system dynamic simulation, making the results of simulation consistent with the actual situation. The unit and grid coupling model which reflects the interaction between thermal system of power plant and power system is built using EMTDC/PSCAD. The influence of nonlinear characteristics on the valve opening and the steam turbine mechanical power is also analyzed in this paper. The results of simulation show that the improper setting of parameters reflecting nonlinear characteristics of turbine governor can lead to the cyclical oscillations of the valve opening and the?steam turbine mechanical power, and even can lead to the power oscillation persistently. The research achievements in this paper have a certain reference value on exploring the causes of power oscillation from the prime mover.展开更多
文摘As the existing coordinated control strategies between grid and unit have limitations in isolated power system, this paper introduces new coordinated control strategies which can improve the stability of isolated system operation. This paper analyzes the power grid side and unit side influence factors on the isolated power system. The dynamic models which are suitable for islanding operation are applied to simulate and analyze the stability and dynamic characteristics of the isolated power system under the conditions of different load disturbances and governor parameters. With considering the differences of frequency characteristics between the interconnected and isolated power system, the adjusting and optimization methods of under frequency load shedding are proposed to meet the frequency stability requirements simultaneously in the two cases. Not only proper control strategies of the power plant but the settings of their parameters are suggested to improve the operation stability of the isolated power system. To confirm the correctness and effectiveness of the method mentioned above, the isolated system operation test was conducted under the real power system condition, and the results show that the proposed coordinated control strategies can greatly improve stability of the isolated power system.
文摘In this paper, the model of turbine governor?based on the physical principles is constituted to improve the accuracy of power system dynamic simulation, making the results of simulation consistent with the actual situation. The unit and grid coupling model which reflects the interaction between thermal system of power plant and power system is built using EMTDC/PSCAD. The influence of nonlinear characteristics on the valve opening and the steam turbine mechanical power is also analyzed in this paper. The results of simulation show that the improper setting of parameters reflecting nonlinear characteristics of turbine governor can lead to the cyclical oscillations of the valve opening and the?steam turbine mechanical power, and even can lead to the power oscillation persistently. The research achievements in this paper have a certain reference value on exploring the causes of power oscillation from the prime mover.