Regenerator is one of the most crucial components to pulse tube cooler (PTC) and thermoacoustic engine. As such regenerator is scaled up to high-power, the thermal and hydrodynamic communication transverse to the acou...Regenerator is one of the most crucial components to pulse tube cooler (PTC) and thermoacoustic engine. As such regenerator is scaled up to high-power, the thermal and hydrodynamic communication transverse to the acoustic axis gets weaker and weaker. Under this condition, any unsymmetric factor could cause serious instability to the cooler or engine, which degrades their performance. Investigation has been carried out on a high-power two-stage thermal-coupled U-shape Stirling-type PTC. By detailed circumferential temperature measurements along the middle heat exchanger and second stage regen-erator, a kind of temperature inhomogeneity caused by unsymmetric pre-cooling effect of inter-stage thermal bridge was found in the lower part of the regenerator of the PTC. The temperature inhomoge-neity originating from the middle heat exchanger of the second stage regenerator amplified itself in the lower part of the regenerator and then internal streaming formed. The maximal radial temperature dif-ference could reach 30―40 K. Experimental results show that the temperature inhomogeneity intensi-fies with increased pre-cooling power and its direction can be reversed by changing the pre-cooling effect of the first stage PTC to heating effect by using external thermal load. This research shows that it is important to maintain the heating or cooling effects of heat exchangers uniform in high-power re-generative coolers and engines.展开更多
基金supported by the National Natural Science Foundation of China(No.50776076)the Doctoral Fund of the Ministry of Education of China(No.20110101110022)the National Funds for Distinguished Young Scientists of China(No.50825601)
基金Supported by the German Ministry of Economics and Technology (BMWi) (Grant Nos. 03SX221A)German Academic Exchange Service (DAAD) Foundation
文摘Regenerator is one of the most crucial components to pulse tube cooler (PTC) and thermoacoustic engine. As such regenerator is scaled up to high-power, the thermal and hydrodynamic communication transverse to the acoustic axis gets weaker and weaker. Under this condition, any unsymmetric factor could cause serious instability to the cooler or engine, which degrades their performance. Investigation has been carried out on a high-power two-stage thermal-coupled U-shape Stirling-type PTC. By detailed circumferential temperature measurements along the middle heat exchanger and second stage regen-erator, a kind of temperature inhomogeneity caused by unsymmetric pre-cooling effect of inter-stage thermal bridge was found in the lower part of the regenerator of the PTC. The temperature inhomoge-neity originating from the middle heat exchanger of the second stage regenerator amplified itself in the lower part of the regenerator and then internal streaming formed. The maximal radial temperature dif-ference could reach 30―40 K. Experimental results show that the temperature inhomogeneity intensi-fies with increased pre-cooling power and its direction can be reversed by changing the pre-cooling effect of the first stage PTC to heating effect by using external thermal load. This research shows that it is important to maintain the heating or cooling effects of heat exchangers uniform in high-power re-generative coolers and engines.