Laboratory results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control 被引量:6
1
作者 W.R.Reed G.J.Joy +2 位作者 M.Shahan S.Klima g.ross 《International Journal of Coal Science & Technology》 EI 2019年第1期15-26,共12页
Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow. NIOSH tested it due to its unique design that differed from canopies that provided uniform airflow. Based upon NIOSH ... Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow. NIOSH tested it due to its unique design that differed from canopies that provided uniform airflow. Based upon NIOSH recommendations from the earlier testing, a 3rd generation roof bolter CAC has been developed by J.H. Fletcher & Co. The changes to this CAC involve design modifications to the plenum outlets, using a single row of outlets on the perimeter and a different material for the plenum. This laboratory testing was a continuation of the original perimeter slotted CAC design. Using gravimetric and instantaneous sampling of respirable dust concentrations underneath and outside of the CAC. the laboratory testing was completed using three different blower fans that delivered differing airflows. The maximum plenum airflow velocities ranged from 2.34 to 3.64 m/s (460-716 fpm). Results showed plenum respirable dust concentrations ranging from 34.6% to 49.3% lower than respirable dust concentrations outside the plenum protection zone, thus showing an improvement in protection for the roof bolter operators. 展开更多
关键词 ROOF bolter Respirable DUST CANOPY air CURTAIN COAL mining
在线阅读 下载PDF
Field study results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control 被引量:4
2
作者 W.R.Reed M.Shahan +4 位作者 S.Klima g.ross K.Singh R.Cross T.Grounds 《International Journal of Coal Science & Technology》 EI 2020年第1期79-87,共9页
A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow... A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow across the canopy area as recommended by the National Institute for Occupational Safety and Health.The new modifications include a plenum that is constructed of a single flat aluminum plate,smaller-diameter airflow openings,and a single row of perimeter nozzles designed to prevent mine air contaminated by respirable dust from entering the CAC protection zone.Field testing was conducted on this new 3rd generation design showing reductions in coal mine respirable dust exposure for roof bolter operators.Dust control efficiencies for the CAC for the left bolter operator(intake side)ranged from approximately 26%–60%,while the efficiencies for the CAC for the right bolter operator(return side)ranged from 3%to 47%. 展开更多
关键词 Roof bolter Respirable dust Coal mining Canopy air curtain
在线阅读 下载PDF