This paper investigated the flow distribution and total pressure drop across a designed 3-D filter housing integrated with a 3-stage filtration system using computa- tional fluid dynamics (CFD). The filter housing m...This paper investigated the flow distribution and total pressure drop across a designed 3-D filter housing integrated with a 3-stage filtration system using computa- tional fluid dynamics (CFD). The filter housing model was proposed for a heavy-duty industrial gas turbine plant operating at an average ambient temperature of 20℃.The pressure drops across the classes of filters were 652.8 Pa, 2692.2 Pa, 887.8 Pa, 776.2 Pa and 2304.2 Pa for I-GB, GB-GA, GA-FA, FA-HA, and HA-O, respectively. The results obtained indicated an acceptable total pressure drop of 7.2% for the entire filter housing before filter clean-up. Although the CFD simulation result shows that small outlet flow velocity and transonic flows exist at the outlet of the filter housing, the designed filter housing was proved compatible with the studied GT, for inlet flow conditions between 600≤ Wair≤610 kg/s and 60≤Vair≤70 m/s for the air flow rate and velocity, respectively. Furthermore, the designed filter housing could be adopted for the studied GT and locations of Usan and Maiduguri in Nigeria, and other locations with similar environmental conditions.展开更多
In this paper, the end-use efficiencies of the different energy carriers and the overall energy efficiency in the Nigerian residential sector (NRS) were estimated using energy and exergy analysis. The energy and exe...In this paper, the end-use efficiencies of the different energy carriers and the overall energy efficiency in the Nigerian residential sector (NRS) were estimated using energy and exergy analysis. The energy and exergy flows were considered from 2006 to 2011. The overall energy efficiency ranges from 19.15% in 2006 to 20.19% in 2011 with a mean of (19.96±0.23)% while the overall exergy efficiency ranges from 4.34% in 2006 to 4.40% in 2011 with a mean of (4.31±0.059)%. The energy and exergy efficiency margin was 15.58% with a marginal improvement of 0.07% and 0.02%, respectively when compared with previous results. The contribution of the energy carriers to the total energy and exergy inputs were 1.45% and 1.43% for electricity, 1.95% and 3% for fossil fuel and 96.6% and 95.57% for bio-fuel. The result shows that approximately 65% of the residence use wood and biomass for domestic cooking and heating, and only a fraction of the residence have access to electricity. LPG was found to be the most efficient while kerosene, charcoal, wood and other biomass the least in this order. Electricity utilization exergy efficiency is affected by vapor-compression air conditioning application apart from low potential energy applications. In addition, this paper has suggested alternatives in the end-use application and has demonstrated the relevance of exergy analysis in enhancing sustainable energy policies and management and improved integration techniques.展开更多
文摘This paper investigated the flow distribution and total pressure drop across a designed 3-D filter housing integrated with a 3-stage filtration system using computa- tional fluid dynamics (CFD). The filter housing model was proposed for a heavy-duty industrial gas turbine plant operating at an average ambient temperature of 20℃.The pressure drops across the classes of filters were 652.8 Pa, 2692.2 Pa, 887.8 Pa, 776.2 Pa and 2304.2 Pa for I-GB, GB-GA, GA-FA, FA-HA, and HA-O, respectively. The results obtained indicated an acceptable total pressure drop of 7.2% for the entire filter housing before filter clean-up. Although the CFD simulation result shows that small outlet flow velocity and transonic flows exist at the outlet of the filter housing, the designed filter housing was proved compatible with the studied GT, for inlet flow conditions between 600≤ Wair≤610 kg/s and 60≤Vair≤70 m/s for the air flow rate and velocity, respectively. Furthermore, the designed filter housing could be adopted for the studied GT and locations of Usan and Maiduguri in Nigeria, and other locations with similar environmental conditions.
文摘In this paper, the end-use efficiencies of the different energy carriers and the overall energy efficiency in the Nigerian residential sector (NRS) were estimated using energy and exergy analysis. The energy and exergy flows were considered from 2006 to 2011. The overall energy efficiency ranges from 19.15% in 2006 to 20.19% in 2011 with a mean of (19.96±0.23)% while the overall exergy efficiency ranges from 4.34% in 2006 to 4.40% in 2011 with a mean of (4.31±0.059)%. The energy and exergy efficiency margin was 15.58% with a marginal improvement of 0.07% and 0.02%, respectively when compared with previous results. The contribution of the energy carriers to the total energy and exergy inputs were 1.45% and 1.43% for electricity, 1.95% and 3% for fossil fuel and 96.6% and 95.57% for bio-fuel. The result shows that approximately 65% of the residence use wood and biomass for domestic cooking and heating, and only a fraction of the residence have access to electricity. LPG was found to be the most efficient while kerosene, charcoal, wood and other biomass the least in this order. Electricity utilization exergy efficiency is affected by vapor-compression air conditioning application apart from low potential energy applications. In addition, this paper has suggested alternatives in the end-use application and has demonstrated the relevance of exergy analysis in enhancing sustainable energy policies and management and improved integration techniques.