期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A novel superconducting magnetic levitation method to support the laser fusion capsule by using permanent magnets 被引量:5
1
作者 Xiaojia Li Tingting Xiao +3 位作者 fengwei chen Yingjuan Zhang Xiaofei Li Weidong Wu 《Matter and Radiation at Extremes》 SCIE EI CAS 2018年第3期104-109,共6页
A novel magnetic levitation support method is proposed, which can relieve the perturbation caused by traditional support methods andprovide more accurate position control of the capsule. This method can keep the perfe... A novel magnetic levitation support method is proposed, which can relieve the perturbation caused by traditional support methods andprovide more accurate position control of the capsule. This method can keep the perfect symmetry of the octahedral spherical hohlraum and hasthe characteristics in stability, tunability and simplicity. It is also favorable that all the results, such as supporting forces acting on the super-conducting capsule, are calculated analytically, and numerical simulations are performed to verify these results. A typical realistic design isproposed and discussed in detail. The superconducting coating material is suggested, and the required superconducting properties are listed.Damped oscillation of the floating capsule in thin helium gas is discussed, and the restoring time is estimated. 展开更多
关键词 ICF capsule support Magnetic levitation SYMMETRY
在线阅读 下载PDF
Orthogonal projection based subspace identification against colored noise 被引量:2
2
作者 Jie HOU Tao LIU fengwei chen 《Control Theory and Technology》 EI CSCD 2017年第1期69-77,共9页
In this paper, a bias-eliminated subspace identification method is proposed for industrial applications subject to colored noise. Based on double orthogonal projections, an identification algorithm is developed to eli... In this paper, a bias-eliminated subspace identification method is proposed for industrial applications subject to colored noise. Based on double orthogonal projections, an identification algorithm is developed to eliminate the influence of colored noise for consistent estimation of the extended observability matrix of the plant state-space model. A shift-invariant approach is then given to retrieve the system matrices from the estimated extended observability matrix. The persistent excitation condition for consistent estimation of the extended observability matrix is analyzed. Moreover, a numerical algorithm is given to compute the estimation error of the estimated extended observability matrix. Two illustrative examples are given to demonstrate the effectiveness and merit of the proposed method. 展开更多
关键词 Subspace identification colored noise orthogonal projection extended observability matrix consistent estimation
原文传递
Assessment of Perfusion Volumes by a New Automated Software for Computed Tomography Perfusion 被引量:1
3
作者 Zhixin Cao David Wang +12 位作者 Xueyan Feng Pengfei Yang Hao Wang Ziqi Xu Yahui Hao Wanxing Ye fengwei chen Liyuan Wang Manjun Hao Na Wu Kai-Xuan Yang Yunyun Xiong Yongjun Wang 《Stroke & Vascular Neurology》 CSCD 2024年第6期693-698,共6页
Introduction To compare the perfusion volumes assessed by a new automated CT perfusion(CTP)software iStroke with the circular singular value decomposition software RAPID and determine its predictive value for function... Introduction To compare the perfusion volumes assessed by a new automated CT perfusion(CTP)software iStroke with the circular singular value decomposition software RAPID and determine its predictive value for functional outcome in patients with acute ischaemic stroke(AIS)who underwent endovascular treatment(EVT).Methods Data on patients with AIS were collected from four hospitals in China.All patients received CTP followed by EVT with complete recanalisation within 24 hours of symptom onset.We evaluated the agreement of CTP measures between the two softwares by Spearman’s rank correlation tests and kappa tests.Bland-Altman plots were used to evaluate the agreement of infarct core volume(ICV)on CTP and ground truth on diffusion-weighted imaging(DWI).Logistic regression models were used to test the association between ICV on these two softwares and functional outcomes.Results Among 326 patients,228 had DWI examinations and 40 of them had infarct volume>70 mL.In all patients,the infarct core and hypoperfusion volumes on iStroke had a strong correlation with those on RAPID(p=0.68 and 0.66,respectively).The agreement of large infarct core(volume>70 mL)was substantial(kappa=0.73,p<0.001)between these two softwares.The ICV measured by iStroke and RAPID was significantly correlated with independent functional outcome at 90 days(p=0.009 and p<0.001,respectively).In patients with DWI examinations and those with an ICV>70 mL,the ICV of iStroke and RAPID was comparable on individual agreement with ground truth.Conclusion The automatic CTP software iStroke is a reliable tool for assessing infarct core and mismatch volumes,making it clinically useful for selecting patients with AIS for acute reperfusion therapy in the extended time window. 展开更多
关键词 RAPID PERFUSION ACUTE
原文传递
上一页 1 下一页 到第