An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the me...An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph.A thorough parametric evaluation of the HG and SAGD system was performed,including the type and concentration of ca rrier acid,He flow rate,concentrations of NaBH4,discha rge current and discharge gap.Under optimal operating conditions,the detection limit for Hg^(2+) achieved 0.03 μg/L,with a relative standard deviation of 1.1% at the Hg^(2+) concentration of 5 μg/L.Moreover,the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L.The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101 b(human hair),GBW10029(fish),soil and rice samples.The results showed good agreement with the certified values and values from direct mercury analyzer(DMA).展开更多
基金the Instrument Development Project of the Chinese Academy of Sciences(No.YZ201539)the National Natural Science Foundation of China(No.21175145)Shanghai Technical Platform for Testing on Inorganic Materials(No.19DZ2290700)。
文摘An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph.A thorough parametric evaluation of the HG and SAGD system was performed,including the type and concentration of ca rrier acid,He flow rate,concentrations of NaBH4,discha rge current and discharge gap.Under optimal operating conditions,the detection limit for Hg^(2+) achieved 0.03 μg/L,with a relative standard deviation of 1.1% at the Hg^(2+) concentration of 5 μg/L.Moreover,the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L.The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101 b(human hair),GBW10029(fish),soil and rice samples.The results showed good agreement with the certified values and values from direct mercury analyzer(DMA).