The measurement of the bound-state decay of^(205)Tl at the Experimental Storage Ring(ESR)at GSI,Darmstadt,has recently been reported,with substantial impact on the use of^(205)Pb as an early Solar System chronometer a...The measurement of the bound-state decay of^(205)Tl at the Experimental Storage Ring(ESR)at GSI,Darmstadt,has recently been reported,with substantial impact on the use of^(205)Pb as an early Solar System chronometer and on the low-energy measurement of the solar neutrino spectrum via the LOREX project.Owing to the technical challenges in producing a high-purity^(205)T^(l81+)secondary beam,a robust statistical method was developed to estimate the variation in the contaminant^(205)Pb^(81+)produced in the fragmentation reaction,which was subsequently transmitted and stored in the ESR.Here,we show that Bayesian and Monte Carlo methods produce comparable estimates for the contaminant variation,each with unique advantages and challenges given the complex statistical problems for this experiment.We recommend the adoption of such methods in future experiments that exhibit unknown statistical fluctuations.展开更多
Precision mass measurements of neutron-deficient 152Sm projectile fragments were conducted in 2005 at theFRS-ESR facility at GSI Helmholtz centre[1, 2], employing the time-resolved Schottky Mass Spectrometry[3]. A new...Precision mass measurements of neutron-deficient 152Sm projectile fragments were conducted in 2005 at theFRS-ESR facility at GSI Helmholtz centre[1, 2], employing the time-resolved Schottky Mass Spectrometry[3]. A newmass evaluation method has been developed in the data analysis. The systematic error in the mass determinationwas significantly reduced with the new method[4].Exotic nuclei, produced by projectile fragmentation of a 615 AMeV 152Sm primary beam in a 4.009 g/cm2beryllium target, were transmitted and B-separated by the fragment separator FRS and then injected and storedin the experimental storage ring ESR. In ESR the electron-cooling process was continuously applied to the storedions. To first order approximation, the revolution-frequencies (f) of the stored ions in the ESR are related to theirvelocities (v) and mass-to-charge ratios (m=q) of the ions in rest frame:展开更多
A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the...A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations.展开更多
基金funding from the European Research Council(ERC)under the European Union's Horizon 2020 research and innovation programme(Grant Agreement No.682841"ASTRUm"and No.654002"ENSAR2")The research of G.Leckenby,I.Dillmann,and C.Griffin was funded by the Canadian Natural Sciences and Engineering Research Council(NSERC)via the grant SAPIN-2019-00030+1 种基金J.Glorius,M.S.Sanjari,Yu.A.Litvinov and C.Brandau acknowledge support by the State of Hesse within the Research Cluster ELEMENTS(Project ID 500/10.006)E.Menz and Yu.A.Litvinov acknowledge support by the project"NRW-FAIR",a part of the programme"Netzwerke 2021",an initiative of the Ministry of Culture and Science of the State of North Rhine-Westphalia.R.Gernhäuser acknowledges support by the Excellence Cluster ORIGINS from the German Research Foundation DFG(Excellence Strategy EXC-2094-390783311)。
文摘The measurement of the bound-state decay of^(205)Tl at the Experimental Storage Ring(ESR)at GSI,Darmstadt,has recently been reported,with substantial impact on the use of^(205)Pb as an early Solar System chronometer and on the low-energy measurement of the solar neutrino spectrum via the LOREX project.Owing to the technical challenges in producing a high-purity^(205)T^(l81+)secondary beam,a robust statistical method was developed to estimate the variation in the contaminant^(205)Pb^(81+)produced in the fragmentation reaction,which was subsequently transmitted and stored in the ESR.Here,we show that Bayesian and Monte Carlo methods produce comparable estimates for the contaminant variation,each with unique advantages and challenges given the complex statistical problems for this experiment.We recommend the adoption of such methods in future experiments that exhibit unknown statistical fluctuations.
文摘Precision mass measurements of neutron-deficient 152Sm projectile fragments were conducted in 2005 at theFRS-ESR facility at GSI Helmholtz centre[1, 2], employing the time-resolved Schottky Mass Spectrometry[3]. A newmass evaluation method has been developed in the data analysis. The systematic error in the mass determinationwas significantly reduced with the new method[4].Exotic nuclei, produced by projectile fragmentation of a 615 AMeV 152Sm primary beam in a 4.009 g/cm2beryllium target, were transmitted and B-separated by the fragment separator FRS and then injected and storedin the experimental storage ring ESR. In ESR the electron-cooling process was continuously applied to the storedions. To first order approximation, the revolution-frequencies (f) of the stored ions in the ESR are related to theirvelocities (v) and mass-to-charge ratios (m=q) of the ions in rest frame:
基金Supported by National Natural Science Foundation of China(10925526,11079044)
文摘A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations.