A two-step methodology was used to address and improve the power quality concerns for the PV-integrated microgrid system. First, partial shading was included to deal with the real-time issues. The Improved Jelly Fish ...A two-step methodology was used to address and improve the power quality concerns for the PV-integrated microgrid system. First, partial shading was included to deal with the real-time issues. The Improved Jelly Fish Algorithm integrated Perturb and Obserb (IJFA-PO) has been proposed to track the Global Maximum Power Point (GMPP). Second, the main unit-powered via DC–AC converter is synchronised with the grid. To cope with the wide voltage variation and harmonic mitigation, an auxiliary unit undergoes a novel series compensation technique. Out of various switching approaches, IJFA-based Selective Harmonic Elimination (SHE) in 120° conduction gives the optimal solution. Three switching angles were obtained using IJFA, whose performance was equivalent to that of nine switching angles. Thus, the system is efficient with minimised higher-order harmonics and lower switching losses. The proposed system outperformed in terms of efficiency, metaheuristics, and convergence. The Total Harmonic Distortion (THD) obtained was 1.32%, which is within the IEEE 1547 and IEC tolerable limits. The model was developed in MATLAB/Simulink 2016b and verified with an experimental prototype of grid-synchronised PV capacity of 260 W tested under various loading conditions. The present model is reliable and features a simple controller that provides more convenient and adequate performance.展开更多
In this paper,an improved load sharing strategy is proposed for distributed generation units(DGs)connected in a microgrid.Conventional frequency and voltage droop control result in unacceptable active and reactive pow...In this paper,an improved load sharing strategy is proposed for distributed generation units(DGs)connected in a microgrid.Conventional frequency and voltage droop control result in unacceptable active and reactive power sharing.The proposed method formulates a suitable algorithm for load sharing in the islanded microgrid.The feeder power loss and the line impedance voltage drops are minimized so as to regulate the voltage at the point of common coupling(PCC)at its nominal value.The desired DG output voltages are calculated and a linear relationship is obtained between the shared active and reactive powers and the DG output voltages.A master DG controller sets the frequency which is followed by other DG units.The reference powers for the DG units are adjusted so as to maintain the rated PCC voltage.The proposed strategy is verified taking into account the DG ratings,unequal line impedance drops,feeder losses,change in system impedance and effect of DG local loads and formulates an improved power sharing strategy that also facilitates PCC voltage regulation under variable loading conditions.Simulation and experimental results are presented to verify the effectiveness of the proposed method.展开更多
文摘A two-step methodology was used to address and improve the power quality concerns for the PV-integrated microgrid system. First, partial shading was included to deal with the real-time issues. The Improved Jelly Fish Algorithm integrated Perturb and Obserb (IJFA-PO) has been proposed to track the Global Maximum Power Point (GMPP). Second, the main unit-powered via DC–AC converter is synchronised with the grid. To cope with the wide voltage variation and harmonic mitigation, an auxiliary unit undergoes a novel series compensation technique. Out of various switching approaches, IJFA-based Selective Harmonic Elimination (SHE) in 120° conduction gives the optimal solution. Three switching angles were obtained using IJFA, whose performance was equivalent to that of nine switching angles. Thus, the system is efficient with minimised higher-order harmonics and lower switching losses. The proposed system outperformed in terms of efficiency, metaheuristics, and convergence. The Total Harmonic Distortion (THD) obtained was 1.32%, which is within the IEEE 1547 and IEC tolerable limits. The model was developed in MATLAB/Simulink 2016b and verified with an experimental prototype of grid-synchronised PV capacity of 260 W tested under various loading conditions. The present model is reliable and features a simple controller that provides more convenient and adequate performance.
文摘In this paper,an improved load sharing strategy is proposed for distributed generation units(DGs)connected in a microgrid.Conventional frequency and voltage droop control result in unacceptable active and reactive power sharing.The proposed method formulates a suitable algorithm for load sharing in the islanded microgrid.The feeder power loss and the line impedance voltage drops are minimized so as to regulate the voltage at the point of common coupling(PCC)at its nominal value.The desired DG output voltages are calculated and a linear relationship is obtained between the shared active and reactive powers and the DG output voltages.A master DG controller sets the frequency which is followed by other DG units.The reference powers for the DG units are adjusted so as to maintain the rated PCC voltage.The proposed strategy is verified taking into account the DG ratings,unequal line impedance drops,feeder losses,change in system impedance and effect of DG local loads and formulates an improved power sharing strategy that also facilitates PCC voltage regulation under variable loading conditions.Simulation and experimental results are presented to verify the effectiveness of the proposed method.