期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Effect of human autologous serum and fetal bovine serum on human corneal epithelial cell viability,migration and proliferation in vitro 被引量:7
1
作者 Ming-Feng Wu Tanja Stachon1 +2 位作者 berthold seitz Achim Langenbucher Nora Szentmary 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期908-913,共6页
AIM: To analyze the concentration-dependent effects of autologous serum (AS) and fetal bovine serum (FBS) on human corneal epithelial cell (HCEC) viability, migration and proliferation. METHODS: AS was prepar... AIM: To analyze the concentration-dependent effects of autologous serum (AS) and fetal bovine serum (FBS) on human corneal epithelial cell (HCEC) viability, migration and proliferation. METHODS: AS was prepared from 13 patients with non- healing epithelial defects Dulbecco's modified eagle medium/ Ham's F12 (DMEM/F12) with 5% FBS, 0.5% dimethyl sulphoxide (DMSO), 10 ng/mL human epidermal growth factor, 1% insulin-transferrin-selenium, then were incubated in serum media: DMEM/F12 supplemented by 5%, 10%, 15% or 30% AS or FBS. HCEC viability was analyzed using cell proliferation kit XTI', migration using a wound healing assay, proliferation by the cell proliferation enzyme-linked immunosorbent assay (ELISA) BrdU kit. Statistical analysis was performed using the generalized linear model, the values at 30% AS or 30% FBS were used as the baselines. RESULTS: HCEC viability was the highest at 30% AS or 15% FBS and the lowest at 10% AS or 30% FBS application. HCEC migration was the quickest through 30% AS or 30% FBS and the slowest through 5% AS or 5% FBS concentrations. Proliferation was the most increased through 15% AS or 5% FBS and the least increased through 30% AS or 30% FBS concentrations. HCEC viability at 10% and 15% AS was significantly worse (P=0.001, P=0.023) compared to baseline and significantly better at 15% FBS (P=0.003) concentrations. HCEC migration was significantly worse (P〈0.007) and HCEC proliferation significantly better (P〈0.001) in all concentration groups compared to baseline. CONCLUSION: For the best viability of HCEC 30% AS or 15% FBS, for HCEC migration 30% AS or 30% FBS, for proliferation 15% AS or 5% FBS should be used. Therefore, we suggest the use of 30% AS in clinical practice. 展开更多
关键词 autologous serum eye drops serum concen-tration MIGRATION PROLIFERATION VIABILITY human comeal epithelialcells
原文传递
Impact of crosslinking/riboflavin-UVA-photodynamic inactivation on viability,apoptosis and activation of human keratocytes in vitro 被引量:2
2
作者 Tanja Stachon Jiong Wang +3 位作者 Xufei Song Achim Langenbucher berthold seitz Nóra Szentmáry 《The Journal of Biomedical Research》 CAS CSCD 2015年第4期321-325,共5页
Riboflavin-UVA photodynamic inactivation is a potential treatment altemative in therapy resistant infectious keratitis. The purpose of our study was to determine the impact of riboflavin-UVA photodynamic inactivation ... Riboflavin-UVA photodynamic inactivation is a potential treatment altemative in therapy resistant infectious keratitis. The purpose of our study was to determine the impact of riboflavin-UVA photodynamic inactivation on viability, apop- tosis and activation of human keratocytes in vitro. Primary human keratocytes were isolated from human corneal buttons and cultured in DMEM/Ham's F12 medium supplemented with 10% fetal calf serum. Keratocytes underwent UVA light illumination (375 nm) for 4.10 minutes (2 J/cm2) during exposure to different concentrations of riboflavin. Twenty-four hours after treatment, cell viability was evaluated photometrically, whereas apoptosis, CD34 and alpha-smooth muscle actin (α-SMA) expression were assessed using flow cytometry. We did not detect significant changes in cell viability, apoptosis, CD34 and α-SMA expression in groups only treated with riboflavin or UVA light. In the group treated with riboflavin-UVA-photodynamic inactivation, viability of keratocytes decreased significantly at 0.1% riboflavin (P〈0.01) while the percentage of CD34 (P〈0.01 for both 0.05% and 0.1% riboflavin) and alpha-SMA positive keratocytes (P〈0.01 and P〈0.05 for 0.05% and 0.1% riboflavin, respectively) increased significantly compared to the controls. There was no significant change in the percentage of apoptotic keratocytes compared to controls at any of the used ribo- flavin concentrations (P=0.09 and P=0.13). We concluded that riboflavin-UVA-photodynamic-inactivation decreases viability of myofibroblastic transformation and multipotent haematopoietic stem cell transformation; however, it does not have an impact on apoptosis of human keratocytes in vitro. 展开更多
关键词 CROSSLINKING human keratocytes VIABILITY APOPTOSIS A-SMA CD34
暂未订购
Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient
3
作者 Xue-Fei Song Achim Langenbucher +2 位作者 Zisis Gatzioufas berthold seitz Moatasem El-Husseiny 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第6期854-857,共4页
AIM: To determine the impact of biometric characteristics on the biomechanical properties of the human cornea using the ocular response analyzer (ORA) and standard comprehensive ophthalmic examinations before and a... AIM: To determine the impact of biometric characteristics on the biomechanical properties of the human cornea using the ocular response analyzer (ORA) and standard comprehensive ophthalmic examinations before and after standard phacoemulsificaUon. METHODS: This study comprised 54 eyes with cataract with significant lens opacification in stages I or II that underwent phacoemulsification (2.8 mm incision). Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were measured by ORA preoperatively and at lmo postoperatively. Biometric characteristics were derived from corneal topography [TMS-5, anterior equivalent (EQTMS) and cylindric (CYLTMS) power], corneal tomography [Casia, anterior and posterior equivalent (EQaCASC, EQpCASIA) and cylindric (CYLaCASIA, CYLpCASIA) power], keratometry [IOLMaster, anterior equivalent (EQIOL) and cylindric (CYL,oL) power] and autorefractor [anterior equivalent (EQAR)]. Results from ORA were analyzed and correlated with those from all other examinations taken at the same time point. RESULTS: Preoperatively, CH correlated with EQpCASIA and CYLpCASIA only (P=0.001, P=0.002). Postoperatively, IOPg and IOPcc correlated with all equivalent powers (EQTMS, EQIOL, EQAR, EQaCASIA, and EQpCASIA)(P=0.001, P=0.007, P=0.001, P= 0.015, P=0.03 for IOPg and P〈0.001, ,0=0.003, P〈0.001, P= 0.009, P=0.014 for IOPcc). CH correlated postoperatively with EQaCASIA and EQpCASIA only (P=0.021, P=0.022). CONCLUSION: Biometric characteristics may significantly affect biomechanical properties of the cornea in terms of CH, IOPcc and IOPg before, but even more after cataract surgery. 展开更多
关键词 cataract surgery biometric characteristics biomechanical properties ocular response analyzer cornealtomography correlation analysis
原文传递
Reactive uveitis, retinal vasculitis and scleritis as ocular end-stage of Acanthamoeba keratitis: a histological study
4
作者 Lei Shi Tobias Hager +6 位作者 Fabian Norbert Fries Loay Daas Leonard Holbach Carmen Hofmann-Rummelt Elena Zemova berthold seitz Nóra Szentmáry 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1966-1971,共6页
We analysed histologically two Acanthamoeba keratitis(AK) eyes with anterior and posterior segment inflammation and blindness. Two enucleated eyes of 2 patients(age 45 and 51y) with AK(PCR of epithelial abrasion posit... We analysed histologically two Acanthamoeba keratitis(AK) eyes with anterior and posterior segment inflammation and blindness. Two enucleated eyes of 2 patients(age 45 and 51y) with AK(PCR of epithelial abrasion positive) were analysed. Histological analysis was performed using hematoxylin-eosin, periodic acid-Schiff and G?m?rimethenamine silver staining. We could not observe Acanthamoeba trophozoites or cysts neither in the cornea nor in other ocular tissues. Meanwhile, we found uveitis, retinal vasculitis and scleritis in these eyes, due to the long-standing, recalcitrant AK. So in this stage of AK, systemic immune suppression may be necessary for a longer time period. 展开更多
关键词 Acanthamoeba keratitis ENUCLEATION UVEITIS retinal vasculitis SCLERITIS
原文传递
Macular vascularisation changes analysed using OCT angiography after successful rhegmatogenous retinal detachment repair
5
作者 Marie Hartmann Alaa Din Abdin +3 位作者 Doris Fraenkel Christian Munteanu berthold seitz Shady Suffo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第1期81-87,共7页
AIM:To analyse the macular vascularisation changes analysed using optical coherence tomography angiography(OCTA)after successful rhegmatogenous retinal detachment(RRD)repair by comparing gas vs silicone oil and macula... AIM:To analyse the macular vascularisation changes analysed using optical coherence tomography angiography(OCTA)after successful rhegmatogenous retinal detachment(RRD)repair by comparing gas vs silicone oil and macula-on vs macula-off.METHODS:This retrospective data collection included 77 eyes with RRD that underwent pars plana vitrectomy(PPV)and gas or silicone oil tamponade.We performed an OCTA during the postoperative control between 6 and 24mo after the last surgery and evaluated the main parameters measured by OCTA:foveal avascular zone(FAZ)and parafoveolar vascular density(PVD)in the superficial capillary plexus.The patients were divided into four groups:RRD with macular involvement treated with gas tamponade,RRD without macular involvement treated with gas tamponade,RRD with macular involvement treated with silicone oil tamponade and RRD without macular involvement treated with silicone oil tamponade.A one-way ANOVA test combined with post hoc Bonferroni corrections compared FAZ sizes and PVD in all four groups.RESULTS:The FAZ size was statistically significantly larger in eyes with RRD involving the macula than in those not involving it(P=0.005).There was no statistically significant difference in the FAZ sizes of the eyes treated with silicone oil tamponade compared to those treated with gas tamponade(P=0.54).There was no statistically significant difference in the PVD comparing all four groups.CONCLUSION:Despite the known risks associated with silicone oil,our findings suggest that the type of tamponade used during PPV to treat an RRD has no significant effect on the future integrity of the PVD or the size of the FAZ in the superficial capillary plexus as measured by OCTA. 展开更多
关键词 RETINA VITRECTOMY optical coherence tomography angiography
原文传递
Scanning-slit topography in patients with keratoconus
6
作者 László Módis Jr. Gábor Németh +2 位作者 Eszter Szalai Zsuzsa Flaskó berthold seitz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1686-1692,共7页
AIM: To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus.METHODS: Orbscan II measurements ... AIM: To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus.METHODS: Orbscan II measurements were taken in 39 keratoconic corneas previously diagnosed by corneal topography and in 39 healthy eyes. The central minimum, maximum, and astigmatic simulated keratometry(K) and anterior axial power values were determined. Spherical and cylindrical mean power diopters were obtained at the central and at the steepest point of the cornea both on anterior and on posterior mean power maps. Pachymetry evaluations were taken at the center and paracentrally in the 3 mm zone from the center at a location of every 45 degrees. Receiver operating characteristic(ROC) analysis was used to determine the best cut-off values and to evaluate the utility of the measured parameters in identifying patients with keratoconus.RESULTS: The minimum, maximum and astigmatic simulated K readings were 44.80±3.06 D, 47.17±3.67 D and 2.42±1.84 D respectively in keratoconus patients and these values differed significantly(P〈0.0001 for all comparisons) from healthy subjects. For all pachymetry measurements and for anterior and posterior mean power values significant differences were found between the two groups. Moreover, anterior central cylindrical power had the best discrimination ability(area under the ROC curve=0.948).CONCLUSION: The results suggest that scanning-slit topography and pachymetry are accurate methods both for keratoconus screening and for confirmation of the diagnosis. 展开更多
关键词 keratoconus Orbscan topography pachymetry
原文传递
圆锥角膜穿透性角膜移植术后缝线相关的角膜规则程度的动态变化 被引量:3
7
作者 刘毅 berthold seitz +2 位作者 Achim Langenbucher Nhung X.Nguyen Gottfried O.H.Naumann 《中国实用眼科杂志》 CSCD 北大核心 2007年第4期366-369,共4页
目的分析圆锥角膜(KC)手术前后角膜规则程度的变化,以及角膜缝线拆除对角膜规则程度的影响,对激光穿透性角膜移植手术(PK)在KC治疗中的作用进行评价。方法回顾分析了236例圆锥角膜使用激光环钻技术进行的穿透性角膜移植手术手术... 目的分析圆锥角膜(KC)手术前后角膜规则程度的变化,以及角膜缝线拆除对角膜规则程度的影响,对激光穿透性角膜移植手术(PK)在KC治疗中的作用进行评价。方法回顾分析了236例圆锥角膜使用激光环钻技术进行的穿透性角膜移植手术手术,使用角膜曲率计(Ophthalmometer,Type-H,190071Zeiss,Jena,Germany)对手术前后的角膜规则程度进行检测,并结合所测出的角膜曲率(K)值和角膜映光图像分成4组:(0)规则组,K〈50D;(1)轻度不规则组,K〈60;(2)中度不规则组,K≥60;(3)重度不规则组,K值不能读出,共4组。手术后第12、18个月依次拆除连续缝线,并同时随访记录各组别角膜规则程度,动态分析以上三个时间点角膜规则程度的变化特点。结果在三个时间点,规则组比例的递增趋势为4%-37%-61%轻度不规则组的变化趋势为12%-51%-33‰中度不规则组的递减趋势为38%-10%-4%;重度不规则组的变化趋势为46%-2%-2%。结论使用激光环钻和16针双线连续缝合的圆锥角膜手术病例中,穿透性角膜移植手术能有效改善病人的角膜表面规则程度,与缝线拆除相关的角膜规则程度呈动态变化,该变化主要发生在轻、中度组,缝线拆除本身并不会导致术后角膜规则程度下降。 展开更多
关键词 圆锥角臆 穿透性角膜移植术 角膜规则程魔 缝线拆除
原文传递
Systematic Cross-biospecimen Evaluation of DNA Extraction Kits for Long-and Short-read Multi-metagenomic Sequencing Studies 被引量:1
8
作者 Jacqueline Rehner Georges Pierre Schmartz +16 位作者 Laura Groeger Jan Dastbaz Nicole Ludwig Matthias Hannig Stefan Rupf berthold seitz Elias Flockerzi Tim Berger Matthias Christian Reichert Marcin Krawczyk Eckart Meese Christian Herr Robert Bals Soren L.Becker Andreas Keller Rolf Muller The IMAGINE Consortium 《Genomics, Proteomics & Bioinformatics》 SCIE CAS CSCD 2022年第2期405-417,共13页
High-quality DNA extraction is a crucial step in metagenomic studies.Bias by different isolation kits impairs the comparison across datasets.A trending topic is,however,the analysis of multiple metagenomes from the sa... High-quality DNA extraction is a crucial step in metagenomic studies.Bias by different isolation kits impairs the comparison across datasets.A trending topic is,however,the analysis of multiple metagenomes from the same patients to draw a holistic picture of microbiota associated with diseases.We thus collected bile,stool,saliva,plaque,sputum,and conjunctival swab samples and performed DNA extraction with three commercial kits.For each combination of the specimen type and DNA extraction kit,20-gigabase(Gb)metagenomic data were generated using short-read sequencing.While profiles of the specimen types showed close proximity to each other,we observed notable differences in the alpha diversity and composition of the microbiota depending on the DNA extraction kits.No kit outperformed all selected kits on every specimen.We reached consistently good results using the Qiagen QiAamp DNA Microbiome Kit.Depending on the specimen,our data indicate that over 10 Gb of sequencing data are required to achieve sufficient resolution,but DNA-based identification is superior to identification by mass spectrometry.Finally,longread nanopore sequencing confirmed the results(correlation coefficient>0.98).Our results thus suggest using a strategy with only one kit for studies aiming for a direct comparison of multiple microbiotas from the same patients. 展开更多
关键词 Whole-genome analysis Comparative genomics Short-read sequencing Long-read sequencing DNA extraction Metagenomics
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部