In this paper eight successive experimental blast tests with an increasing TNT equivalent charge weights ranging from 0.56 kg to 17.78 kg were conducted on unreinforced,ferrocemented overlay masonry and confined mason...In this paper eight successive experimental blast tests with an increasing TNT equivalent charge weights ranging from 0.56 kg to 17.78 kg were conducted on unreinforced,ferrocemented overlay masonry and confined masonry walls.The pressure-time history caused by the blast was recorded by pressure sensors installed on the test specimen.The resulting damage pattern was observed during each test.Weak zones in the three systems of masonry were identified.Scaled distances for different damage levels in the three masonry systems were experimentally obtained.The results provide a basis for determining the response of each masonry system against blast loading.Consequently,efficiency of ferrocemented overlay masonry and confined masonry was found established in mitigation against blast loads.展开更多
Beam-column connections are one of the most critical elements of reinforced concrete structures,especially in seismically active regions,and have been extensively evaluated experimentally and numerically.However,very ...Beam-column connections are one of the most critical elements of reinforced concrete structures,especially in seismically active regions,and have been extensively evaluated experimentally and numerically.However,very limited experimental studies about eccentric reinforced concrete connections including the effect of connected slabs are available.This study presents the experimental results of two half-scale eccentric beam-column-slab connections subjected to quasi-static cyclic loading.The horizontal eccentricity(eh)is maintained at 12.5%and 25%of column width(bc)for specimens 1 and 2,respectively.The damage pattern,performance levels,displacement ductility(μD),energy dissipation,and connection strength and stiffness are compared for both specimens,and the effect of eccentricity is evaluated.It is concluded that the eccentricity has no significant effect on the lateral load carrying capacity;however,the overall strength degradation increases with the increase in eccentricity.Similarly,the elastic stiffness of specimen 2 decreased by 14%as the eccentricity increased from 12.5%to 25%;however,the eccentricity had no significant effect on the overall stiffness degradation.μD decreased by 43%,and the energy dissipation capacity decreased by 40%in specimen 2 with higher eccentricity.The story drifts corresponding to the performance levels of the life safety(LS)and collapse prevention(CP)were found to be 28%lesser in specimen 2 than in specimen 1.展开更多
文摘In this paper eight successive experimental blast tests with an increasing TNT equivalent charge weights ranging from 0.56 kg to 17.78 kg were conducted on unreinforced,ferrocemented overlay masonry and confined masonry walls.The pressure-time history caused by the blast was recorded by pressure sensors installed on the test specimen.The resulting damage pattern was observed during each test.Weak zones in the three systems of masonry were identified.Scaled distances for different damage levels in the three masonry systems were experimentally obtained.The results provide a basis for determining the response of each masonry system against blast loading.Consequently,efficiency of ferrocemented overlay masonry and confined masonry was found established in mitigation against blast loads.
文摘Beam-column connections are one of the most critical elements of reinforced concrete structures,especially in seismically active regions,and have been extensively evaluated experimentally and numerically.However,very limited experimental studies about eccentric reinforced concrete connections including the effect of connected slabs are available.This study presents the experimental results of two half-scale eccentric beam-column-slab connections subjected to quasi-static cyclic loading.The horizontal eccentricity(eh)is maintained at 12.5%and 25%of column width(bc)for specimens 1 and 2,respectively.The damage pattern,performance levels,displacement ductility(μD),energy dissipation,and connection strength and stiffness are compared for both specimens,and the effect of eccentricity is evaluated.It is concluded that the eccentricity has no significant effect on the lateral load carrying capacity;however,the overall strength degradation increases with the increase in eccentricity.Similarly,the elastic stiffness of specimen 2 decreased by 14%as the eccentricity increased from 12.5%to 25%;however,the eccentricity had no significant effect on the overall stiffness degradation.μD decreased by 43%,and the energy dissipation capacity decreased by 40%in specimen 2 with higher eccentricity.The story drifts corresponding to the performance levels of the life safety(LS)and collapse prevention(CP)were found to be 28%lesser in specimen 2 than in specimen 1.