In this paper,we have successfully demonstrated a Q-switched pulse generation utilizing lutetium oxide(Lu2O3)thin film based saturable absorber(SA)in all-fiber erbium-doped fiber laser(EDFL)cavity with a bidirectional...In this paper,we have successfully demonstrated a Q-switched pulse generation utilizing lutetium oxide(Lu2O3)thin film based saturable absorber(SA)in all-fiber erbium-doped fiber laser(EDFL)cavity with a bidirectional pumping.The Lu2O3 powder is mixed with isopropyl alcohol(IPA)solution before we add polyvinyl alcohol(PVA)as our host polymer to make the Lu2O3 into a thin film.By inserting the Lu2O3-PVA thin film into a bidirectional pumped EDFL cavity,a stable Q-switched pulse is realized with repetition rate in a range of rose from 43.67 k Hz to 57.74 k Hz whereas the pulse width decreased from 14.48μs to 11.20μs.This result indicates that the Lu2O3 can be implemented as an SA device in an EDFL as it owns a linear absorption of around 3 d B at 1567 nm.展开更多
In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical r...In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems.展开更多
基金support from Higher Council of Turkey under the Mevlana Program(Project No.MEV.2019-1750)Kütahya Dumlup?nar University(Project No.DPU.2020-20)。
文摘In this paper,we have successfully demonstrated a Q-switched pulse generation utilizing lutetium oxide(Lu2O3)thin film based saturable absorber(SA)in all-fiber erbium-doped fiber laser(EDFL)cavity with a bidirectional pumping.The Lu2O3 powder is mixed with isopropyl alcohol(IPA)solution before we add polyvinyl alcohol(PVA)as our host polymer to make the Lu2O3 into a thin film.By inserting the Lu2O3-PVA thin film into a bidirectional pumped EDFL cavity,a stable Q-switched pulse is realized with repetition rate in a range of rose from 43.67 k Hz to 57.74 k Hz whereas the pulse width decreased from 14.48μs to 11.20μs.This result indicates that the Lu2O3 can be implemented as an SA device in an EDFL as it owns a linear absorption of around 3 d B at 1567 nm.
文摘In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems.