A model coupling the plasma with a cathode body is applied in the simulation of the diffuse state of a magnetically rotating arc.Four parametric studies are performed:on the external axial magnetic field(AMF),on th...A model coupling the plasma with a cathode body is applied in the simulation of the diffuse state of a magnetically rotating arc.Four parametric studies are performed:on the external axial magnetic field(AMF),on the cathode shape,on the total current and on the inlet gas velocity.The numerical results show that:the cathode attachment focuses in the center of the cathode tip with zero AMF and gradually shifts off the axis with the increase of AMF;a larger cathode conical angle corresponds to a cathode arc attachment farther away off axis;the maximum values of plasma temperature increase with the total current;the plasma column in front of the cathode tip expands more severely in the axial direction,with a higher inlet speed;the cathode arc attachment shrinks towards the tip as the inlet speed increases.The various results are supposed to be explained by the joint effect of coupled cathode surface heating and plasma rotating flow.展开更多
The effect of an axial magnetic field (AMF) on an old xenon short-arc lamp is experimentally investigated in this work. As the AMF increases up to 18 roT, the visible radiation power and electric power ascend more t...The effect of an axial magnetic field (AMF) on an old xenon short-arc lamp is experimentally investigated in this work. As the AMF increases up to 18 roT, the visible radiation power and electric power ascend more than 80% and 70% respectively, and the radiation efficiency is improved by 23% for the best increment at 12 mT AMF. The measurement of radiation intensity shows that the increment of radiation intensity comes mostly from the plasma area close to the cathode tip, and partially from the other area of the arc column. Successive images of the arc indicate that the arc column not only rotates about its axis, but revolves around the axis of electrodes with the AMF. The arc column structure is constricted, distorted and elongated as the AMF increases. It is suggested that the improvements of the radiation intensity and radiation efficiency are attributed to the constriction of the arc column, which is mainly induced by the enhanced cathode jet.展开更多
基金supported by National Natural Science Foundation of China(Nos.11475174,11035005 and 50876101)
文摘A model coupling the plasma with a cathode body is applied in the simulation of the diffuse state of a magnetically rotating arc.Four parametric studies are performed:on the external axial magnetic field(AMF),on the cathode shape,on the total current and on the inlet gas velocity.The numerical results show that:the cathode attachment focuses in the center of the cathode tip with zero AMF and gradually shifts off the axis with the increase of AMF;a larger cathode conical angle corresponds to a cathode arc attachment farther away off axis;the maximum values of plasma temperature increase with the total current;the plasma column in front of the cathode tip expands more severely in the axial direction,with a higher inlet speed;the cathode arc attachment shrinks towards the tip as the inlet speed increases.The various results are supposed to be explained by the joint effect of coupled cathode surface heating and plasma rotating flow.
基金supported by National Natural Science Foundation of China (Nos.50876101,11035005)the Science Instrument Foundation of CAS
文摘The effect of an axial magnetic field (AMF) on an old xenon short-arc lamp is experimentally investigated in this work. As the AMF increases up to 18 roT, the visible radiation power and electric power ascend more than 80% and 70% respectively, and the radiation efficiency is improved by 23% for the best increment at 12 mT AMF. The measurement of radiation intensity shows that the increment of radiation intensity comes mostly from the plasma area close to the cathode tip, and partially from the other area of the arc column. Successive images of the arc indicate that the arc column not only rotates about its axis, but revolves around the axis of electrodes with the AMF. The arc column structure is constricted, distorted and elongated as the AMF increases. It is suggested that the improvements of the radiation intensity and radiation efficiency are attributed to the constriction of the arc column, which is mainly induced by the enhanced cathode jet.