摘要
论述了该厂300MW机组火电厂化学水处理一级除盐设备再生的酸碱用量调整试验的基本过程,并对一级除盐设备运行提出了相应的措施,调整试验达到节约酸碱用量、降低生产成本的目的。
The article expounded the basic process of adjusting experiment of regeneration acid and alkali consumption in water treatment of the first level demineralizing system for 300 MW unit in ther mal power plant.Besides,it put forward some effective measure for the operation of this system.The adjusting experiment acconrplished the purpose to economize t he regeneration scid and alkali consumption,and lower the production cost as wel l.
出处
《湖北电力》
2003年第3期56-57,共2页
Hubei Electric Power
关键词
火电厂
化学水处理
一级除盐系统
再生
酸碱用量
调整
<Key words>the first level demineralizing
ion exchange
acid consumption
alkali cons umption